{"id":24014,"date":"2026-11-25T10:14:30","date_gmt":"2026-11-25T02:14:30","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/carton-compression-stack-load-duration\/"},"modified":"2026-11-25T10:14:30","modified_gmt":"2026-11-25T02:14:30","slug":"carton-compression-stack-load-duration","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/","title":{"rendered":"Carton Compression: Separate Peak Load from Stack Duration"},"content":{"rendered":"<div class=\"weho-blog\">\n<div class=\"key-takeaways\"><strong>Key Engineering Takeaways<\/strong><\/p>\n<ul>\n<li>A brief compression result and sustained stacking resistance answer different questions.<\/li>\n<li>Specify the complete filled package, orientation, load path, environment and exposure duration.<\/li>\n<li>Calculate the assumed load above the package without converting that calculation into a qualified stack height.<\/li>\n<li>Agree product and package acceptance criteria before the packaging laboratory runs the test.<\/li>\n<\/ul>\n<\/div>\n<figure class=\"article-figure hero\" data-asset=\"K18-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/ur\/product\/lrs-series-400w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"LRS-400-24 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/3c057ec44cefc101-lrs-400-24-application.avif\" alt=\"LRS-400-24 product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>Application illustration of LRS-400-24 in an equipment setting; not a customer installation photo. Scene created with AI assistance. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/37fc252f0794f33d-application-master.webp\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#turn-a-stacking-concern-into-a-packaging-test-request\">Turn a stacking concern into a packaging test request<\/a><\/li>\n<li><a href=\"#name-the-two-mechanical-questions-separately\">Name the two mechanical questions separately<\/a><\/li>\n<li><a href=\"#calculate-a-hypothetical-bottom-carton-load\">Calculate a hypothetical bottom-carton load<\/a><\/li>\n<li><a href=\"#preserve-the-filled-package-configuration\">Preserve the filled-package configuration<\/a><\/li>\n<li><a href=\"#define-acceptance-before-seeing-the-result\">Define acceptance before seeing the result<\/a><\/li>\n<li><a href=\"#build-a-laboratory-ready-compression-brief\">Build a laboratory-ready compression brief<\/a><\/li>\n<li><a href=\"#prepare-a-shipment-specific-enquiry\">Prepare a shipment-specific enquiry<\/a><\/li>\n<li><a href=\"#engineering-faq\">Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0645\u0646\u062f\u0631\u062c\u0627\u062a \u06a9\u0627 \u062c\u062f\u0648\u0644<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u0679\u0648\u06af\u0644 \u06a9\u0631\u06cc\u06ba\u06d4<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Turn_a_stacking_concern_into_a_packaging_test_request\" >Turn a stacking concern into a packaging test request<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Name_the_two_mechanical_questions_separately\" >Name the two mechanical questions separately<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Calculate_a_hypothetical_bottom-carton_load\" >Calculate a hypothetical bottom-carton load<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Preserve_the_filled-package_configuration\" >Preserve the filled-package configuration<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Define_acceptance_before_seeing_the_result\" >Define acceptance before seeing the result<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Build_a_laboratory-ready_compression_brief\" >Build a laboratory-ready compression brief<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Prepare_a_shipment-specific_enquiry\" >Prepare a shipment-specific enquiry<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Does_a_high_compression_peak_prove_a_safe_long-duration_stack\" >Does a high compression peak prove a safe long-duration stack?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Should_the_contents_be_included_in_the_test\" >Should the contents be included in the test?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Is_6174_N_a_WEHO_carton_rating\" >Is 617.4 N a WEHO carton rating?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/ur\/news\/carton-compression-stack-load-duration\/#Can_the_same_approval_cover_a_different_divider_or_product_count\" >Can the same approval cover a different divider or product count?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"turn-a-stacking-concern-into-a-packaging-test-request\"><span class=\"ez-toc-section\" id=\"Turn_a_stacking_concern_into_a_packaging_test_request\"><\/span>Turn a stacking concern into a packaging test request<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A supplier&#39;s carton compression number is useful only when its specimen and loading conditions match the purchasing question. A package that withstands a brief high force may still require different evidence for days of sustained loading. Treat the storage route and its duration as design inputs instead of approving stacking from one attractive maximum value.<\/p>\n<p>For shipments containing the <a href=\"https:\/\/www.wehopower.com\/ur\/product\/lrs-series-400w-ac-to-dc-single-output-switching-power-supply\/\">WEHO LRS-400-24 product reference<\/a>, identify the actual product count, packaging configuration and shipment revision. The product photograph identifies the component being packed. It does not define a carton construction, a permitted stacking load or an approved distribution test.<\/p>\n<p>Begin with the route from packing through transport, warehouse storage and unpacking. Record whether cartons remain in a palletized unit, are restacked individually or support different items. A drawing of the initial pallet is insufficient if later handling creates a different load path.<\/p>\n<h2 id=\"name-the-two-mechanical-questions-separately\"><span class=\"ez-toc-section\" id=\"Name_the_two_mechanical_questions_separately\"><\/span>Name the two mechanical questions separately<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A compression test can characterize resistance under a defined loading method. ASTM&#39;s public <a href=\"https:\/\/store.astm.org\/standards\/d642\" target=\"_blank\" rel=\"noopener\">D642 scope and significance<\/a> identifies shipping containers, components and unit loads, including different orientations and packages tested with or without contents. The scope also points to a separate method for constant-load testing.<\/p>\n<p>ASTM&#39;s public <a href=\"https:\/\/store.astm.org\/standards\/d4577\" target=\"_blank\" rel=\"noopener\">D4577 description<\/a> addresses vertically applied constant load for a specified period or until failure. That distinction matters when a procurement requirement concerns storage duration. The public descriptions establish the method distinction; they are not a substitute for the complete applicable laboratory procedure.<\/p>\n<p>A test request should therefore name its objective before selecting a method. Is the team comparing two carton constructions, evaluating a defined sustained stack or investigating a damage mechanism? A useful report must preserve the objective and actual conditions so its result can be interpreted for the intended route.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Question<\/th>\n<th scope=\"col\">Required evidence<\/th>\n<th scope=\"col\">Record separately<\/th>\n<th scope=\"col\">Insufficient substitute<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Resistance under the selected compression method<\/td>\n<td>Force\/displacement behavior and defined endpoint<\/td>\n<td>Specimen, platen, orientation and loading method<\/td>\n<td>A number with no test configuration<\/td>\n<\/tr>\n<tr>\n<td>Resistance under sustained stacking<\/td>\n<td>Specified load and duration, or time to the defined failure<\/td>\n<td>Environment, load distribution and observations<\/td>\n<td>A brief peak-load result alone<\/td>\n<\/tr>\n<tr>\n<td>Protection of the actual product<\/td>\n<td>Agreed checks of the packed contents and package<\/td>\n<td>Product positions and internal support<\/td>\n<td>An exterior carton that merely looks intact<\/td>\n<\/tr>\n<tr>\n<td>Coverage of the route<\/td>\n<td>Defined distribution hazards and relevant test scope<\/td>\n<td>Palletized and individual-carton stages<\/td>\n<td>A claim that one test reproduces every shipment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"calculate-a-hypothetical-bottom-carton-load\"><span class=\"ez-toc-section\" id=\"Calculate_a_hypothetical_bottom-carton_load\"><\/span>Calculate a hypothetical bottom-carton load<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume eight identical cartons are stacked vertically, each with a total packed mass of 9.0 kg. Consider the load delivered by the seven cartons above the bottom carton. Assume a stable vertical load path and use g = 9.8 m\/s\u00b2 for this teaching calculation; exclude a pallet or other additional load above the stack.<\/p>\n<p>The supported mass is 7 \u00d7 9.0 = 63.0 kg. Its gravitational force is 63.0 \u00d7 9.8 = 617.4 N. This calculation estimates one static load boundary under the stated assumptions. It is not a package rating or an instruction to stack LRS-400-24 shipments eight cartons high.<\/p>\n<p>The bottom carton&#39;s own mass is not added as another entire carton above its top surface. Its contents and internal supports can nevertheless affect how the complete package carries and distributes force. Define the physical boundary in the drawing rather than treating every mass in the shipment as interchangeable.<\/p>\n<p>Suppose a fictional short-duration test reports a maximum force of 1,500 N before its specified endpoint. Dividing 1,500\/617.4 gives approximately 2.43. That arithmetic ratio does not establish a 2.43 safety factor for prolonged storage, because the time, environment, specimen variation and failure criterion have not been matched.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Hypothetical record<\/th>\n<th scope=\"col\">Known quantity<\/th>\n<th scope=\"col\">What it supports<\/th>\n<th scope=\"col\">What remains open<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Eight-carton arrangement<\/td>\n<td>63.0 kg above the bottom carton<\/td>\n<td>617.4 N assumed static load boundary<\/td>\n<td>Actual route and load distribution<\/td>\n<\/tr>\n<tr>\n<td>Brief compression result<\/td>\n<td>Assumed 1,500 N endpoint<\/td>\n<td>That specimen under that recorded method<\/td>\n<td>Sustained-load performance<\/td>\n<\/tr>\n<tr>\n<td>Proposed storage trial<\/td>\n<td>Defined load, duration and environment<\/td>\n<td>A plan for the specific stacking question<\/td>\n<td>Actual observations and acceptance decision<\/td>\n<\/tr>\n<tr>\n<td>Final shipping configuration<\/td>\n<td>Product, cushioning, carton and pallet revision<\/td>\n<td>Identity of the package to evaluate<\/td>\n<td>Approval until the required evidence is complete<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure class=\"article-figure technical\" data-asset=\"K18-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/363d19c9b5380a70-carton-stack-load-versus-peak.svg\" alt=\"Carton example separates the calculated upper-stack load from a brief compression peak and duration evidence.\" width=\"1200\" height=\"675\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Seven fictional upper cartons of 9.0 kg create a 617.4 N static load using g = 9.8 m\/s\u00b2. The assumed 1,500 N brief endpoint and its 2.43 ratio do not establish a stack rating, duration or WEHO packaging qualification. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/363d19c9b5380a70-carton-stack-load-versus-peak.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>No carton strength or time-to-failure is predicted here. A loading fixture can distribute force differently from the real upper carton or pallet, and the package may change during conditioning. The packaging engineer and laboratory should resolve those differences before declaring that the test covers the route.<\/p>\n<h2 id=\"preserve-the-filled-package-configuration\"><span class=\"ez-toc-section\" id=\"Preserve_the_filled-package_configuration\"><\/span>Preserve the filled-package configuration<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Document the box construction, dimensions, closure, dividers, cushioning and product placement. Record whether the contents are intended to share compressive load or remain isolated from it. Packaging tested empty can answer another question from the same outer carton tested with its actual contents and internal supports.<\/p>\n<p>The <a href=\"https:\/\/ista.org\/getting_started_with_design.php\" target=\"_blank\" rel=\"noopener\">ISTA guide to selecting distribution tests<\/a> starts with understanding how packages are shipped, handled and stored. Its distinction between screening and prediction helps keep the requested conclusion proportional to the selected evidence. Do not describe a convenient screening test as a complete reproduction of an unmeasured distribution system.<\/p>\n<figure class=\"article-figure product\" data-asset=\"K18-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/ur\/product\/lrs-series-400w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"LRS-400-24 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/0f29ed8b4c6b5ff9-lrs-400-24-product-reference.avif\" alt=\"LRS-400-24 product reference preserving the original housing, visible label and connection features.\" width=\"1000\" height=\"1000\" decoding=\"async\" title=\"\"><\/a><figcaption>Product appearance reference for LRS-400-24, preserving the source housing, visible label and connections. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/44622179442b7304-product-original.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<p>Agree which changes require reassessment. A revised divider, product count, closure tape, packing orientation or pallet arrangement can change the tested configuration. Keep the bill of packaging materials and photographs tied to the report so a lower-cost substitution is not silently included in an earlier result.<\/p>\n<h2 id=\"define-acceptance-before-seeing-the-result\"><span class=\"ez-toc-section\" id=\"Define_acceptance_before_seeing_the_result\"><\/span>Define acceptance before seeing the result<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Package acceptance should identify meaningful conditions, not only whether the carton collapses. The intended decision may require limits on deformation, loss of stack stability, protective separation or damage to the product and terminals. Use the project&#39;s actual requirements; this article supplies no universal allowable crush dimension or electrical post-test criterion.<\/p>\n<p>Plan how and when observations will be made. A package may support load throughout a test but reveal damage only after opening, while an exterior mark may have no functional consequence under the agreed criteria. Preserve both observations and their disposition without changing the criteria after a preferred sample has passed.<\/p>\n<p>The existing <a href=\"https:\/\/www.wehopower.com\/ur\/news\/power-supply-shipping-packaging-oem-shipment-evidence\/\">OEM shipping-packaging guide<\/a> addresses physical protection and shipment identity. Add the compression and sustained-load evidence where the route requires it. The records should describe one controlled packing configuration while keeping the different test questions identifiable.<\/p>\n<h2 id=\"build-a-laboratory-ready-compression-brief\"><span class=\"ez-toc-section\" id=\"Build_a_laboratory-ready_compression_brief\"><\/span>Build a laboratory-ready compression brief<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Map the route.<\/strong> Record stack arrangements, handling stages, storage duration and relevant environments. Verify that the brief includes changes after the first dispatch pallet is broken down.<\/li>\n<li><strong>Freeze the package.<\/strong> Record the product count and exact packaging materials, dimensions, closures and support. Verify that submitted samples represent the configuration proposed for shipment.<\/li>\n<li><strong>Define the load boundary.<\/strong> Record masses, load-bearing interfaces and any additional upper load. Verify the arithmetic and label every assumption, including where distribution evidence is missing.<\/li>\n<li><strong>Select the test with the laboratory.<\/strong> Record method, edition, orientation, conditioning, loading history and observations. Verify that the chosen scope addresses the brief rather than merely producing a peak number.<\/li>\n<li><strong>Apply the agreed criteria.<\/strong> Record package and contents results, deviations and decision owner. Verify that any release covers only the evaluated configuration and that relevant changes trigger review.<\/li>\n<\/ol>\n<h2 id=\"prepare-a-shipment-specific-enquiry\"><span class=\"ez-toc-section\" id=\"Prepare_a_shipment-specific_enquiry\"><\/span>Prepare a shipment-specific enquiry<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send WEHO the <a href=\"https:\/\/www.wehopower.com\/ur\/product\/lrs-series-400w-ac-to-dc-single-output-switching-power-supply\/\">LRS-400-24 ordered-product identity<\/a>, quantity per carton, proposed packing drawing and route information. Ask what packaging information is available for the supplied configuration. Keep the laboratory&#39;s test selection and your project&#39;s acceptance requirements explicit.<\/p>\n<p>Before approving a stack, record the load above the package, the time it must remain there and the complete filled configuration. Those three inputs give the packaging team a specific decision to support instead of treating a brief force maximum as a warehouse-life guarantee.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"does-a-high-compression-peak-prove-a-safe-long-duration-stack\"><span class=\"ez-toc-section\" id=\"Does_a_high_compression_peak_prove_a_safe_long-duration_stack\"><\/span>Does a high compression peak prove a safe long-duration stack?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. A peak result applies to its specimen and loading method. Sustained loading introduces a time-dependent question that needs appropriate evidence under the defined environment and package configuration.<\/p>\n<h3 id=\"should-the-contents-be-included-in-the-test\"><span class=\"ez-toc-section\" id=\"Should_the_contents_be_included_in_the_test\"><\/span>Should the contents be included in the test?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The specimen must match the question and selected method. Record whether the container is empty or filled and how its contents and supports carry load; do not transfer a result between configurations without an accepted basis.<\/p>\n<h3 id=\"is-617-4-n-a-weho-carton-rating\"><span class=\"ez-toc-section\" id=\"Is_6174_N_a_WEHO_carton_rating\"><\/span>Is 617.4 N a WEHO carton rating?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. It is the calculated static load from seven fictional 9.0 kg upper cartons. No actual package construction, permitted stack height or qualified duration is established by that calculation.<\/p>\n<h3 id=\"can-the-same-approval-cover-a-different-divider-or-product-count\"><span class=\"ez-toc-section\" id=\"Can_the_same_approval_cover_a_different_divider_or_product_count\"><\/span>Can the same approval cover a different divider or product count?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Only when the responsible review establishes that the approval covers the change. Identify the revised packing configuration and reassess affected evidence rather than assuming that an unchanged outer carton preserves the complete result.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Define carton compression and sustained-stack evidence, calculate the assumed upper load, and send WEHO your LRS-400-24 shipping configuration.<\/p>","protected":false},"author":2,"featured_media":22243,"parent":0,"menu_order":0,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-24014","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/news\/24014","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/comments?post=24014"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/news\/24014\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/media\/22243"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/media?parent=24014"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/news_category?post=24014"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}