{"id":1113,"date":"2021-11-02T02:51:00","date_gmt":"2021-11-02T02:51:00","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=product&#038;p=1113"},"modified":"2026-11-12T15:44:28","modified_gmt":"2026-11-12T07:44:28","slug":"s-350w-series-normal-single-switching-power-supply","status":"publish","type":"product","link":"https:\/\/www.wehopower.com\/ur\/product\/s-350w-series-normal-single-switching-power-supply\/","title":{"rendered":"S-350W series normal single switching power supply"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_tta-container\" data-vc-action=\"collapse\"><div class=\"vc_general vc_tta vc_tta-accordion vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-o-shape-group vc_tta-controls-align-default\"><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel vc_active\" id=\"1636701172155-32719f5d-02c1\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-right\"><a href=\"#1636701172155-32719f5d-02c1\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u0646\u0631\u062f\u062c\u06cc\u06a9\u0631\u0646 \u0627\u0648\u0631 \u0645\u0627\u0688\u0644<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<table width=\"100%\">\n<tbody>\n<tr>\n<td colspan=\"2\">\u0645\u0627\u0688\u0644<\/td>\n<td>S-350-5<\/td>\n<td>S-350-9<\/td>\n<td>S-350-12<\/td>\n<td>S-350-15<\/td>\n<td>S-350-18<\/td>\n<td>S-350-24<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\u0622\u0624\u0679 \u067e\u0679<\/td>\n<td>\u0688\u06cc \u0633\u06cc \u0622\u0624\u0679 \u067e\u0679 \u0648\u0648\u0644\u0679\u06cc\u062c\u060c \u06a9\u0631\u0646\u0679<\/td>\n<td>5V 0 ~ 50A<\/td>\n<td>9V 0 ~ 38A<\/td>\n<td>12V 0 ~ 29A<\/td>\n<td>15V 0 ~ 23.3A<\/td>\n<td>18V 0 ~ 19.4A<\/td>\n<td>24V 0 ~ 14.6A<\/td>\n<\/tr>\n<tr>\n<td>\u0644\u06c1\u0631 \u0627\u0648\u0631 \u0634\u0648\u0631<\/td>\n<td>150mVp-p<\/td>\n<td>150mVp-p<\/td>\n<td>150mVp-p<\/td>\n<td>150mVp-p<\/td>\n<td>150mVp-p<\/td>\n<td>150mVp-p<\/td>\n<\/tr>\n<tr>\n<td>inlet \u062a\u0627\u0631 \u0627\u0633\u062a\u062d\u06a9\u0627\u0645<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<\/tr>\n<tr>\n<td>\u0644\u0648\u0688 \u0627\u0633\u062a\u062d\u06a9\u0627\u0645<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b10.5%<\/td>\n<\/tr>\n<tr>\n<td>\u06a9\u0627\u0631\u06a9\u0631\u062f\u06af\u06cc<\/td>\n<td>73%<\/td>\n<td>78%<\/td>\n<td>83%<\/td>\n<td>83%<\/td>\n<td>84%<\/td>\n<td>85%<\/td>\n<\/tr>\n<tr>\n<td>\u0688\u06cc \u0633\u06cc \u0648\u0648\u0644\u0679\u06cc\u062c \u06a9\u06d2 \u0644\u06cc\u06d2 \u0633\u0627\u06cc\u0688\u0633\u062a \u0631\u06cc\u0646\u062c<\/td>\n<td>\u00b110%<\/td>\n<td>\u00b110%<\/td>\n<td>\u00b110%<\/td>\n<td>\u00b110%<\/td>\n<td>\u00b110%<\/td>\n<td>\u00b110%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\u0627\u0646 \u067e\u0679<\/td>\n<td>\u0627\u0646 \u067e\u0679 \u0648\u0648\u0644\u0679\u06cc\u062c \u06a9\u06cc \u062d\u062f<\/td>\n<td colspan=\"6\">90 ~ 132VAC\/180 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u062b\u0631 \u06a9\u0631\u0646\u0679<\/td>\n<td colspan=\"6\">Cold start current 25A\/115VAC 50A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\u062a\u062d\u0641\u0638<\/td>\n<td>\u0627\u0648\u0648\u0631\u0644\u0648\u0688 \u062a\u062d\u0641\u0638<\/td>\n<td colspan=\"6\">105% ~ 135% cut off the output, automatic recovery<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0648\u0648\u0631 \u0648\u0648\u0644\u0679\u06cc\u062c \u062a\u062d\u0641\u0638<\/td>\n<td colspan=\"6\">115% ~ 150% shut down O\/P voltage, re-power on to recover<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Operating and test conditions<\/td>\n<td>\u0633\u06cc\u0679 \u0627\u067e\u060c \u0627\u0679\u06be\u0646\u0627\u060c \u06c1\u0648\u0644\u0688 \u0627\u067e \u0679\u0627\u0626\u0645<\/td>\n<td colspan=\"6\">200ms, 50ms, 20ms\/230VAC at full load<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0648\u0644\u0679\u06cc\u062c \u06a9\u0627 \u0645\u0642\u0627\u0628\u0644\u06c1 \u06a9\u0631\u06cc\u06ba\u06d4<\/td>\n<td colspan=\"6\">I\/P-O\/P: 1.5kV; I\/P-FG: 1.5kV; O\/P-FG: 0.5kV; 1 minute<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0646\u06c1\u0627\u0626\u06cc \u06a9\u06cc \u0645\u0632\u0627\u062d\u0645\u062a<\/td>\n<td colspan=\"6\">I\/P-O\/P, I\/P-FG, O\/P-FG: 500VDC\/100M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>\u06a9\u0627\u0645 \u06a9\u0631\u0646\u06d2 \u06a9\u0627 \u062f\u0631\u062c\u06c1 \u062d\u0631\u0627\u0631\u062a<\/td>\n<td colspan=\"6\">-10\u00b0C ~ +50\u00b0C<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Others<\/td>\n<td>\u0637\u0648\u0644 \u0648 \u0639\u0631\u0636<\/td>\n<td colspan=\"6\">215 \u00d7 115 \u00d7 50mm<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0632\u0646<\/td>\n<td colspan=\"6\">1kg<\/td>\n<\/tr>\n<tr>\n<td>\u067e\u06cc\u06a9\u0646\u06af<\/td>\n<td colspan=\"6\">45.5 \u00d7 31.5 \u00d7 26CM\/20PCS\/20kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1636701110045-2231239d-d5c7\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-right\"><a href=\"#1636701110045-2231239d-d5c7\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u0688\u06cc\u0632\u0627\u0626\u0646<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left wpb_content_element\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/S-350-1024x284.png\" target=\"_self\" class=\"vc_single_image-wrapper   vc_box_border_grey\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1127\" height=\"313\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/S-350.png\" class=\"vc_single_image-img attachment-full\" alt=\"S 350\" title=\"S 350\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/S-350.png 1127w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/S-350-300x83.png 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/S-350-1024x284.png 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/S-350-768x213.png 768w\" sizes=\"(max-width: 1127px) 100vw, 1127px\" style=\"width:100%;height:27.77%;max-width:1127px;\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1636701110038-e7dfe23b-653a\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-right\"><a href=\"#1636701110038-e7dfe23b-653a\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u062e\u0635\u0648\u0635\u06cc\u0627\u062a<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Why Choose S-350?<\/h2>\n<h3>Specify the intermediate rail deliberately<\/h3>\n<p>S-350 has separate 5V, 9V, 12V, 15V, 18V and 24V output variants. This helps an equipment builder distinguish different pattern-interface or job-memory board requirements without assuming every family offers the same outputs.<\/p>\n<h3>Assess the machine-bay envelope<\/h3>\n<p>The listed body dimensions are 215\u00d7115\u00d750mm. The listed weight is 1kg. Start the layout of a tool-presetting or winding station with these body figures, then separately provide conductor support, terminal access and heat-removal space.<\/p>\n<h3>Resolve the incoming supply before connection<\/h3>\n<p>AC input is 90~132VAC\/180~264VAC by switch; the same input row also lists 254~370VDC and 47~63Hz. A coil-impregnation chamber needs a correctly selected input arrangement independently of its electronics rail. The separate DC listing is not evidence of automatic AC switching.<\/p>\n<h3>Differentiate recovery behavior for local electronics<\/h3>\n<p>Overload protection is listed at 105%~135% with output cutoff and automatic recovery. Overvoltage protection is listed at 115%~150%; the output shuts down and requires re-powering to recover. A wrapper or cleaning-line interface must handle both a recovering overload and an overvoltage shutdown. These supply-protection functions are not a substitute for independent machine protection.<\/p>\n<h2>S-350 Features and Selection Details<\/h2>\n<h3>Six documented output alternatives<\/h3>\n<p>The output table lists S-350-5: 5V, 0~50A; S-350-9: 9V, 0~38A; S-350-12: 12V, 0~29A; S-350-15: 15V, 0~23.3A; S-350-18: 18V, 0~19.4A; S-350-24: 24V, 0~14.6A. These columns define the documented choices in this sheet. Select one of these documented models and confirm its continuous duty; the 350W family summary is not a universal output guarantee.<\/p>\n<h3>A shared printed wave-and-noise entry<\/h3>\n<p>The wave-and-noise entries are S-350-5: 150mVp-p; S-350-9: 150mVp-p; S-350-12: 150mVp-p; S-350-15: 150mVp-p; S-350-18: 150mVp-p; S-350-24: 150mVp-p. Assess the selected board tolerance against its own column. The sheet does not state the measurement bandwidth, and the figure is not a precision reference or sensor-accuracy specification.<\/p>\n<h3>Model-bound line and load stability<\/h3>\n<p>The line\/load-stability entries are S-350-5: line \u00b10.5%, load \u00b10.5%; S-350-9: line \u00b10.5%, load \u00b10.5%; S-350-12: line \u00b10.5%, load \u00b10.5%; S-350-15: line \u00b10.5%, load \u00b10.5%; S-350-18: line \u00b10.5%, load \u00b10.5%; S-350-24: line \u00b10.5%, load \u00b10.5%. These entries support a voltage-budget comparison for compatible interface boards, not a claim about embroidery motion, winding tension or process accuracy.<\/p>\n<h3>Output setting with qualified efficiency use<\/h3>\n<p>Each S-350 output column lists a \u00b110% DC-voltage adjustment range. The efficiency entries are S-350-5: 73%; S-350-9: 78%; S-350-12: 83%; S-350-15: 83%; S-350-18: 84%; S-350-24: 85%. The adjustment changes the DC rail within its stated setting range; it is not current regulation. The efficiency row does not specify typical or full-load conditions and does not establish the installed thermal duty.<\/p>\n<h2>Typical S-350 Service Conditions<\/h2>\n<h3>Temperature at a CNC tool-presetting station<\/h3>\n<p>A CNC tool-presetting station may assess S-350 for compatible local menu and data-interface electronics. The listed working-temperature range is -10\u00b0C~+50\u00b0C. Measure actual bay temperature and keep optics and calibrated sensing separately qualified. The working range does not establish full-load operation throughout the range or machining capability.<\/p>\n<h3>Input selection at a coil-impregnation chamber<\/h3>\n<p>A coil-impregnation chamber may evaluate an exact S-350 variant for compatible recipe-memory and status boards. AC input is 90~132VAC\/180~264VAC by switch; the same input row also lists 254~370VDC and 47~63Hz. Verify the incoming supply and selector before energizing, with the electrical bay isolated from resin and cleaning exposure. Vacuum pumps and process heating remain separate.<\/p>\n<h3>Restart duty on a pallet stretch wrapper<\/h3>\n<p>A pallet stretch wrapper may consider S-350 for compatible recipe-entry and communication electronics. Cold-start current is listed as 25A at 115VAC; 50A at 230VAC. Check repeated-start demand and upstream protection without assigning turntable, carriage or film-tension drives to this rail. Protective controls remain independently designed.<\/p>\n<h3>Power interruption on an ultrasonic cleaning line<\/h3>\n<p>An ultrasonic cleaning line may evaluate S-350 for compatible cycle-display and network-interface boards. Setup, rise and hold-up times are 200ms, 50ms and 20ms, respectively, at 230VAC and full load. Test state recovery under the actual cycle and isolate electronics from liquid and condensation. Ultrasonic generators, heaters and lifting mechanisms need independent power systems.<\/p>\n<h2>Potential S-350 Equipment Applications<\/h2>\n<h3>Multihead embroidery machine<\/h3>\n<p>A multihead embroidery machine may assess an exact S-350 variant for compatible pattern-interface and job-memory boards. Confirm rail voltage, electronic demand and reset behavior. Needle drives, hoop motion, thread-tension control and protective functions remain separately powered and validated; no stitch performance is established.<\/p>\n<h3>Ceramic tile sorting line<\/h3>\n<p>A ceramic tile sorting line may evaluate a selected S-350 output for compatible count-display and communication electronics in a protected bay. Check dust isolation, local temperature and startup demand. Conveyor drives, diverters, machine vision and grading accuracy need separate power and engineering.<\/p>\n<h3>Hydraulic hose crimping press<\/h3>\n<p>A hydraulic hose crimping press may consider an exact S-350 suffix for compatible job-memory and local interface boards. Match the output to those electronics and support the wiring against machine vibration. Hydraulic generation, valve actuation, calibrated crimp measurement and press protection are independent requirements.<\/p>\n<h3>Spool traverse winding station<\/h3>\n<p>A spool traverse winding station may evaluate S-350 for compatible recipe-display and communication boards. Verify the selected electronic rail, restart response and enclosure cooling. Winding and traverse motors, tension regulation and finished-coil quality are outside the proposed supply role.<\/p>\n<h2>S-350 Technical FAQs<\/h2>\n<h3>Which output variants and current ranges are documented for S-350?<\/h3>\n<p>The output table lists S-350-5: 5V, 0~50A; S-350-9: 9V, 0~38A; S-350-12: 12V, 0~29A; S-350-15: 15V, 0~23.3A; S-350-18: 18V, 0~19.4A; S-350-24: 24V, 0~14.6A. The summary states 350W, while S-350-5 is listed at 5V with a 0~50A current range. These are alternative single-output models in this sheet, not simultaneous rails. The zero current lower bounds are not no-load regulation evidence, and the summary must not replace suffix-specific continuous-duty confirmation.<\/p>\n<h3>Which input ranges and selection method are stated for S-350?<\/h3>\n<p>AC input is 90~132VAC\/180~264VAC by switch; the same input row also lists 254~370VDC and 47~63Hz. The AC bands require switch selection. Confirm the separate DC operating case for the delivered version; no automatic AC range switching is stated.<\/p>\n<h3>Which cold-start currents are listed for S-350, and under what inputs?<\/h3>\n<p>Cold-start current is listed as 25A at 115VAC; 50A at 230VAC. Cold-start input current is not normal output current or a continuous input rating. Repeated start duty and protection coordination require an installation assessment.<\/p>\n<h3>How do the wave-and-noise entries vary across S-350 outputs?<\/h3>\n<p>The wave-and-noise entries are S-350-5: 150mVp-p; S-350-9: 150mVp-p; S-350-12: 150mVp-p; S-350-15: 150mVp-p; S-350-18: 150mVp-p; S-350-24: 150mVp-p. All listed columns carry the same printed entry, without a stated measurement bandwidth or test fixture. It does not establish calibrated-reference or precision-sensing performance.<\/p>\n<h3>Which line and load stability values belong to each S-350 suffix?<\/h3>\n<p>The line\/load-stability entries are S-350-5: line \u00b10.5%, load \u00b10.5%; S-350-9: line \u00b10.5%, load \u00b10.5%; S-350-12: line \u00b10.5%, load \u00b10.5%; S-350-15: line \u00b10.5%, load \u00b10.5%; S-350-18: line \u00b10.5%, load \u00b10.5%; S-350-24: line \u00b10.5%, load \u00b10.5%. These percentages describe the printed line and load entries, not an adjustment range or the accuracy of a machine process. The actual board voltage budget remains a separate check.<\/p>\n<h3>What do the DC adjustment and efficiency entries establish for S-350?<\/h3>\n<p>Each S-350 output column lists a \u00b110% DC-voltage adjustment range. The efficiency entries are S-350-5: 73%; S-350-9: 78%; S-350-12: 83%; S-350-15: 83%; S-350-18: 84%; S-350-24: 85%. Efficiency is listed without a typical\/full-load qualifier. The adjustment entry does not establish constant-current operation, a charger or a dimming interface.<\/p>\n<h3>How does the documented S-350 overload response recover?<\/h3>\n<p>Overload protection is listed at 105%~135% with output cutoff and automatic recovery. This is an overload fault response, not a normal current-control mode. The electronic load must tolerate output loss and restart; machine protective functions need their own design.<\/p>\n<h3>How does the documented S-350 overvoltage response recover?<\/h3>\n<p>Overvoltage protection is listed at 115%~150%; the output shuts down and requires re-powering to recover. The re-powering requirement differs from overload automatic recovery. It is not evidence of a safety-rated shutdown or uninterrupted control rail.<\/p>\n<h3>What are the S-350 setup, rise and hold-up times and test condition?<\/h3>\n<p>Setup, rise and hold-up times are 200ms, 50ms and 20ms, respectively, at 230VAC and full load. The setup, rise and hold-up entries apply at the stated 230VAC\/full-load condition. These timings do not qualify every line voltage, temperature or board reset behavior.<\/p>\n<h3>Which working temperature, body dimensions and weight are listed for S-350?<\/h3>\n<p>The listed working-temperature range is -10\u00b0C~+50\u00b0C. The listed body dimensions are 215\u00d7115\u00d750mm. The listed weight is 1kg. Treat the dimensions as a body envelope, not installation clearance. The sheet supplies no full-load-throughout-temperature guarantee or installed-system cooling result.<\/p>\n<h3>Which isolation and withstand test entries are stated for S-350?<\/h3>\n<p>The isolation-resistance row lists 500VDC\/100M\u03a9 for I\/P-O\/P, I\/P-FG and O\/P-FG. Withstand entries are I\/P-O\/P 1.5kV, I\/P-FG 1.5kV and O\/P-FG 0.5kV for 1 minute, without a printed AC\/DC qualifier. The withstand entries contain no AC\/DC test qualifier. These component test statements do not establish certification, an ingress rating or permission to omit a system insulation review.<\/p>\n<h3>What does the S-350 terminal legend establish before wiring?<\/h3>\n<p>The 9-pin drawing legend identifies pins 8,9 AC input; pins 7 GND; pins 4,5,6 DC output-V; pins 1,2,3 DC output+V. The drawing is a generic legend, not proof of exact delivered-suffix wiring. Verify the actual unit markings, polarity, bonding, supported conductors and upstream protection.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"Specifications&amp;Model Model S-350-5 S-350-9 S-350-12 S-350-15 S-350-18 S-350-24 Output DC output voltage,current 5V 0 ~ 50A 9V 0 ~ 38A 12V 0 ~ 29A 15V 0 ~ 23.3A 18V 0 ~ 19.4A 24V 0 ~ 14.6A Wave and noise 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p Inlet wire stability \u00b10.5% \u00b10.5% \u00b10.5% \u00b10.5% \u00b10.5% \u00b10.5% Load&hellip; <a class=\"more-link\" href=\"https:\/\/www.wehopower.com\/ur\/product\/s-350w-series-normal-single-switching-power-supply\/\">\u067e\u0691\u06be\u0646\u0627 \u062c\u0627\u0631\u06cc \u0631\u06a9\u06be\u06cc\u06ba <span class=\"screen-reader-text\">S-350W series normal single switching power supply<\/span><\/a>","protected":false},"author":1,"featured_media":21159,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[35,36],"product_categories_new":[126],"class_list":["post-1113","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-enclosed-switching-power-supply","product_category-s-series-single-output-power-supply","product_categories_new-s-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product\/1113","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/comments?post=1113"}],"version-history":[{"count":2,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product\/1113\/revisions"}],"predecessor-version":[{"id":21746,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product\/1113\/revisions\/21746"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/media\/21159"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/media?parent=1113"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product_category?post=1113"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product_categories_new?post=1113"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}