{"id":8671,"date":"2025-07-18T15:47:20","date_gmt":"2025-07-18T07:47:20","guid":{"rendered":"https:\/\/www.wehopower.com\/?post_type=product&#038;p=8671"},"modified":"2026-11-13T17:52:45","modified_gmt":"2026-11-13T09:52:45","slug":"silm-size-hdr-150-150w-din-rail-switching-power-supply","status":"publish","type":"product","link":"https:\/\/www.wehopower.com\/ur\/product\/silm-size-hdr-150-150w-din-rail-switching-power-supply\/","title":{"rendered":"\u0633\u0644\u0645 \u0633\u0627\u0626\u0632 HDR-150 150W \u062f\u06cc\u0646 \u0631\u06cc\u0644 \u0633\u0648\u0626\u0686\u0646\u06af \u067e\u0627\u0648\u0631 \u0633\u067e\u0644\u0627\u0626\u06cc"},"content":{"rendered":"<p><strong>\u062e\u0644\u0627\u0635\u06c1<\/strong><\/p>\n<p>Single output: power 150W<\/p>\n<p>Input voltage: 85\uff5e264VAC\/120\uff5e370VDC<\/p>\n<p>&nbsp;<\/p>\n<p><strong>\u0639\u0645\u0648\u0645\u06cc \u062a\u0641\u0635\u06cc\u0644\u0627\u062a<\/strong><\/p>\n<table style=\"width: 100%;\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td width=\"202\" height=\"19\">\u062a\u0641\u0635\u06cc\u0644\u0627\u062a<\/td>\n<td width=\"102\">\u0645\u0627\u0688\u0644<\/td>\n<td width=\"159\">HDR-150-12<\/td>\n<td width=\"161\">HDR-150-15<\/td>\n<td width=\"161\">HDR-150-24<\/td>\n<td width=\"159\">HDR-150-48<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"202\" height=\"38\">DC output voltage, current<\/td>\n<td width=\"102\">115VAC<\/td>\n<td width=\"159\">12V 0\uff5e10.2A<\/td>\n<td width=\"161\">15V 0\uff5e8.55A<\/td>\n<td width=\"161\">24V 0\uff5e5.31A<\/td>\n<td width=\"159\">48V 0\uff5e2.72A<\/td>\n<\/tr>\n<tr>\n<td width=\"102\">230VAC<\/td>\n<td width=\"159\">12V 0\uff5e11.3A<\/td>\n<td width=\"161\">15V 0\uff5e9.5A<\/td>\n<td width=\"161\">24V 0\uff5e6.25A<\/td>\n<td width=\"159\">48V 0\uff5e3.2A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0644\u06c1\u0631 \u0627\u0648\u0631 \u0634\u0648\u0631<\/td>\n<td width=\"159\">100mVp-p<\/td>\n<td width=\"161\">120mVp-p<\/td>\n<td width=\"161\">150mVp-p<\/td>\n<td width=\"159\">200mVp-p<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">inlet \u062a\u0627\u0631 \u0627\u0633\u062a\u062d\u06a9\u0627\u0645<\/td>\n<td width=\"159\">\u00b11%<\/td>\n<td width=\"161\">\u00b11%<\/td>\n<td width=\"161\">\u00b11%<\/td>\n<td width=\"159\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0644\u0648\u0688 \u0627\u0633\u062a\u062d\u06a9\u0627\u0645<\/td>\n<td width=\"159\">\u00b11%<\/td>\n<td width=\"161\">\u00b11%<\/td>\n<td width=\"161\">\u00b11%<\/td>\n<td width=\"159\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u06a9\u0627\u0631\u06a9\u0631\u062f\u06af\u06cc<\/td>\n<td width=\"159\">87%<\/td>\n<td width=\"161\">88%<\/td>\n<td width=\"161\">89%<\/td>\n<td width=\"159\">89%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0688\u06cc \u0633\u06cc \u0648\u0648\u0644\u0679\u06cc\u062c \u06a9\u06d2 \u0644\u06cc\u06d2 \u0633\u0627\u06cc\u0688\u0633\u062a \u0631\u06cc\u0646\u062c<\/td>\n<td width=\"159\">\u00b110%<\/td>\n<td width=\"161\">\u00b110%<\/td>\n<td width=\"161\">\u00b110%<\/td>\n<td width=\"159\">\u00b110%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0627\u0646 \u067e\u0679 \u0648\u0648\u0644\u0679\u06cc\u062c \u06a9\u06cc \u062d\u062f<\/td>\n<td colspan=\"4\" width=\"641\">85\uff5e264VAC\/120\uff5e370VDC; 47\uff5e63Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0627\u062b\u0631 \u06a9\u0631\u0646\u0679<\/td>\n<td colspan=\"4\" width=\"641\">Cold start current: 35A\/115VAC; 70A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0627\u0648\u0648\u0631\u0644\u0648\u0688 \u062a\u062d\u0641\u0638<\/td>\n<td colspan=\"4\" width=\"641\">105%\uff5e150% cut off the output, automatic recovery<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">Overvoltage protection<\/td>\n<td colspan=\"4\" width=\"641\">115%\uff5e140% rated output power. Protection type: Hiccup mode, recovers automatically after fault condition is removed<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0633\u06cc\u0679 \u0627\u067e\u060c \u0627\u0679\u06be\u0646\u0627\u060c \u06c1\u0648\u0644\u0688 \u0627\u067e \u0679\u0627\u0626\u0645<\/td>\n<td colspan=\"4\" width=\"641\">1500ms, 80ms\/230VAC; 1500ms, 80ms\/115VAC (at full load)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0648\u0648\u0644\u0679\u06cc\u062c \u06a9\u0627 \u0645\u0642\u0627\u0628\u0644\u06c1 \u06a9\u0631\u06cc\u06ba\u06d4<\/td>\n<td colspan=\"4\" width=\"641\">I\/P-O\/P: 1.5kV; I\/P-FG: 1.5kV; O\/P-FG: 0.5kV; 1 minute<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u062a\u0646\u06c1\u0627\u0626\u06cc \u06a9\u06cc \u0645\u0632\u0627\u062d\u0645\u062a<\/td>\n<td colspan=\"4\" width=\"641\">I\/P-O\/P, I\/P-FG, O\/P-FG: 100M\u03a9 \/ 500VDC \/ 25\u2103 \/ 70%RH<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u06a9\u0627\u0645 \u06a9\u0631\u0646\u06d2 \u06a9\u0627 \u062f\u0631\u062c\u06c1 \u062d\u0631\u0627\u0631\u062a<\/td>\n<td colspan=\"4\" width=\"641\">-20\u2103\uff5e+70\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0637\u0648\u0644 \u0648 \u0639\u0631\u0636<\/td>\n<td colspan=\"4\" width=\"641\">105\u00d790\u00d754.5mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u0648\u0632\u0646<\/td>\n<td colspan=\"4\" width=\"641\">0.3 \u06a9\u0644\u0648\u06af\u0631\u0627\u0645<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"304\" height=\"19\">\u067e\u06cc\u06a9\u0646\u06af<\/td>\n<td colspan=\"4\" width=\"641\">\/<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why choose HDR-150?<\/h2>\n<h3>Defined mechanical envelope<\/h3>\n<p>The stated body dimensions are 105\u00d790\u00d754.5mm. Use these dimensions to allocate panel space, then check the complete drawing, terminal access and nearby equipment.<\/p>\n<h3>Distinct single-output versions<\/h3>\n<p>The listed versions are HDR-150-12, HDR-150-15, HDR-150-24, HDR-150-48. Each is a single-output model, not a simultaneous multi-voltage supply. Match the selected version to the equipment input.<\/p>\n<h3>Documented input coverage<\/h3>\n<p>The specified input ranges are 85\u2013264VAC and 120\u2013370VDC, with an AC frequency range of 47\u201363Hz. Confirm the actual source, wiring requirements and supplied revision.<\/p>\n<h3>Defined overload recovery<\/h3>\n<p>Overload protection is listed at 105%\uff5e150% with output cut-off and automatic recovery. Coordinate the supply and downstream load so a fault response is not treated as normal continuous operation.<\/p>\n<h2>Features and selection benefits<\/h2>\n<h3>Model-specific output information<\/h3>\n<p>At 115VAC: HDR-150-12: 12V 0\uff5e10.2A; HDR-150-15: 15V 0\uff5e8.55A; HDR-150-24: 24V 0\uff5e5.31A; HDR-150-48: 48V 0\uff5e2.72A. At 230VAC: HDR-150-12: 12V 0\uff5e11.3A; HDR-150-15: 15V 0\uff5e9.5A; HDR-150-24: 24V 0\uff5e6.25A; HDR-150-48: 48V 0\uff5e3.2A. Keep each current range with its stated model and input-voltage condition; the family designation does not establish one continuous-power rating for every output option.<\/p>\n<h3>Regulation and adjustment<\/h3>\n<p>Line regulation and load regulation are each listed as \u00b11%. The DC voltage adjustment range is \u00b110%; confirm the connected electronics input limits before adjusting the setting.<\/p>\n<h3>Noise and efficiency data for selection<\/h3>\n<p>Ripple\/noise: HDR-150-12: 100mVp-p; HDR-150-15: 120mVp-p; HDR-150-24: 150mVp-p; HDR-150-48: 200mVp-p. Efficiency: HDR-150-12: 87%; HDR-150-15: 88%; HDR-150-24: 89%; HDR-150-48: 89%. Use the selected model figures in the load noise and power-budget assessment.<\/p>\n<h3>Model-specific terminal information<\/h3>\n<p>Pin 1: AC\/N; pin 2: AC\/L; pins 3 and 4: -V; pins 5 and 6: +V. Check rail fit and terminal access against the exact mechanical drawing. Follow the complete drawing and the installation electrical-safety requirements.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>\u0645\u062c\u0645\u0648\u0639\u06cc \u0637\u0648\u0644 \u0648 \u0639\u0631\u0636 (\u0645\u0644\u06cc \u0645\u06cc\u0679\u0631)<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-8674 size-full\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2025\/07\/Overall-dimension-hdr-150.jpg\" alt=\"\" width=\"1237\" height=\"327\" title=\"\" srcset=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2025\/07\/Overall-dimension-hdr-150.jpg 1237w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2025\/07\/Overall-dimension-hdr-150-300x79.jpg 300w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2025\/07\/Overall-dimension-hdr-150-1024x271.jpg 1024w, https:\/\/www.wehopower.com\/wp-content\/uploads\/2025\/07\/Overall-dimension-hdr-150-768x203.jpg 768w\" sizes=\"(max-width: 1237px) 100vw, 1237px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2>Typical service conditions<\/h2>\n<h3>Panel space and mechanical fit<\/h3>\n<p>Plan around the 105\u00d790\u00d754.5mm body and 0.3kg stated weight. Check rail fit and terminal access against the exact mechanical drawing. Allow for wiring and the surrounding equipment; the body dimensions are not a universal clearance specification.<\/p>\n<h3>Input and terminal checks<\/h3>\n<p>Check the actual supply against 85\u2013264VAC or 120\u2013370VDC and the 47\u201363Hz AC range. Pin 1: AC\/N; pin 2: AC\/L; pins 3 and 4: -V; pins 5 and 6: +V. Confirm DC-input wiring for the selected revision rather than assuming AC labels alone define every DC installation.<\/p>\n<h3>Temperature and load planning<\/h3>\n<p>The working-temperature range is -20\u00b0C to +70\u00b0C. Assess the real enclosure, airflow and selected output load; the stated temperature range alone does not establish full output at every ambient temperature.<\/p>\n<h3>Start-up and fault coordination<\/h3>\n<p>Timing information is listed as 1500ms, 80ms\/230VAC; 1500ms, 80ms\/115VAC (at full load). Cold-start current is 35A\/115VAC; 70A\/230VAC. Keep these figures with their stated input conditions when coordinating upstream protection and downstream start-up.<\/p>\n<h2>Application guidance<\/h2>\n<p>These are potential integration roles, not customer-installation claims. Match the selected voltage, steady-state current, start-up demand and environment before selection.<\/p>\n<h3>Access-control electronics<\/h3>\n<p>Use a voltage-compatible HDR-150 version for reader, controller or interface electronics inside a protected access-control panel. Assess door strikes, motors and pulsed loads separately; a matching nominal voltage alone does not establish suitability.<\/p>\n<h3>Process sensing and monitoring<\/h3>\n<p>Provide local DC power to compatible sensor interfaces, monitoring modules or indication electronics with the selected HDR-150 voltage. Check steady-state and start-up demand and compare ripple\/noise with the measurement-system requirements.<\/p>\n<h3>Building-automation interfaces<\/h3>\n<p>Supply compatible zone-controller or building-management interface electronics in a protected panel. Check the HDR-150 mechanical envelope, panel temperature and load input limits; the supply alone does not establish outdoor or system-level approval.<\/p>\n<h3>Industrial communications equipment<\/h3>\n<p>Power compatible gateways, serial-interface modules or local communications electronics that accept the selected HDR-150 DC input. Verify the whole load budget and start-up conditions; this selection does not add PoE, backup or UPS functions.<\/p>\n<h2>HDR-150 technical FAQs<\/h2>\n<h3>Which DC output models are listed for HDR-150?<\/h3>\n<p>The listed models are HDR-150-12, HDR-150-15, HDR-150-24, HDR-150-48, with nominal outputs of 12V, 15V, 24V, 48V respectively. Each is a single-output version.<\/p>\n<h3>What current ratings are listed for HDR-150?<\/h3>\n<p>At 115VAC: HDR-150-12: 12V 0\uff5e10.2A; HDR-150-15: 15V 0\uff5e8.55A; HDR-150-24: 24V 0\uff5e5.31A; HDR-150-48: 48V 0\uff5e2.72A. At 230VAC: HDR-150-12: 12V 0\uff5e11.3A; HDR-150-15: 15V 0\uff5e9.5A; HDR-150-24: 24V 0\uff5e6.25A; HDR-150-48: 48V 0\uff5e3.2A. Preserve both input-qualified rows; the higher 230VAC values are not unconditional ratings over the whole input range.<\/p>\n<h3>What input-voltage and frequency ranges are specified?<\/h3>\n<p>The input-voltage ranges are 85\u2013264VAC and 120\u2013370VDC. The AC frequency range is 47\u201363Hz. Check the selected unit and installation requirements before connection.<\/p>\n<h3>What line-regulation and load-regulation figures are listed?<\/h3>\n<p>Line regulation and load regulation are each listed as \u00b11% for every output version in this family.<\/p>\n<h3>What DC voltage adjustment range is listed?<\/h3>\n<p>The listed DC voltage adjustment range is \u00b110% for each version. Verify the connected equipment input limits before changing the setting.<\/p>\n<h3>What ripple\/noise values are listed for HDR-150?<\/h3>\n<p>HDR-150-12: 100mVp-p; HDR-150-15: 120mVp-p; HDR-150-24: 150mVp-p; HDR-150-48: 200mVp-p. Confirm any application-specific measurement conditions separately.<\/p>\n<h3>What efficiency values are listed for HDR-150?<\/h3>\n<p>HDR-150-12: 87%; HDR-150-15: 88%; HDR-150-24: 89%; HDR-150-48: 89%. Use the figure for the selected voltage version.<\/p>\n<h3>What cold-start current is specified?<\/h3>\n<p>The listed cold-start current is 35A\/115VAC; 70A\/230VAC. Keep each value tied to its stated AC input when assessing upstream protection.<\/p>\n<h3>How is overload recovery specified?<\/h3>\n<p>The overload range is 105%\uff5e150%, with output cut-off and automatic recovery. Do not treat the protection threshold as a normal continuous operating rating.<\/p>\n<h3>What timing information is provided?<\/h3>\n<p>The timing row lists 1500ms, 80ms\/230VAC; 1500ms, 80ms\/115VAC (at full load). A separate third hold-up-time value is not printed in that row.<\/p>\n<h3>What working-temperature range and dimensions are stated for HDR-150?<\/h3>\n<p>The stated working-temperature range is -20\u00b0C to +70\u00b0C. Body dimensions are 105\u00d790\u00d754.5mm and weight is 0.3kg. Verify thermal performance with the actual load and enclosure rather than assuming full output at every temperature.<\/p>\n<h3>Which terminal assignments are shown for HDR-150?<\/h3>\n<p>Pin 1: AC\/N; pin 2: AC\/L; pins 3 and 4: -V; pins 5 and 6: +V. Check rail fit and terminal access against the exact mechanical drawing. Use the complete drawing and applicable installation instructions for final integration.<\/p>","protected":false},"excerpt":{"rendered":"<p>The HDR-100 can operate on an input voltage range of 86-264VAC and provides an output voltage line of 5V,12V, 24V, and 48V.<\/p>","protected":false},"author":1,"featured_media":21072,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product_category":[80],"product_categories_new":[116],"class_list":["post-8671","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product_category-hdr-series-din-rail-power-supply","product_categories_new-hdr-series","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product\/8671","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/comments?post=8671"}],"version-history":[{"count":2,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product\/8671\/revisions"}],"predecessor-version":[{"id":21688,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product\/8671\/revisions\/21688"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/media\/21072"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/media?parent=8671"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product_category?post=8671"},{"taxonomy":"product_categories_new","embeddable":true,"href":"https:\/\/www.wehopower.com\/ur\/wp-json\/wp\/v2\/product_categories_new?post=8671"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}