...

Product Categories

WEHO HDR-15W Bộ nguồn AC DC 5V 12V 24V 48V Slim DIN Rail

WEHO’s HDR-15 is a compact, single-output DIN-rail power-supply family for panel-mounted control, sensing and communications electronics. Separate 5V, 12V, 24V, 48V versions support voltage-specific selection, while the 17.5×90×54.5mm body gives a defined mechanical envelope. Match the selected model’s current rating and actual installation conditions before ordering.

Nếu bạn có bất kỳ câu hỏi nào, xin vui lòng liên hệ với chúng tôi tại E-mail: [email protected]

WEHO's HDR-15 is a compact, single-output DIN-rail power-supply family for panel-mounted control, sensing and communications electronics. Separate 5V, 12V, 24V, 48V versions support voltage-specific selection, while the 17.5×90×54.5mm body gives a defined mechanical envelope. Match the selected model's current rating and actual installation conditions before ordering.

Người mẫu HDR-15-5 HDR-15-12 HDR-15-24 HDR-15-48
DC output voltage, current 5V 0~2.4A 12V 0~1.25A 24V 0~0.63A 48V 0~0.32A
Sóng Và Tiếng Ồn 80mVp-p 120mVp-p 150mVp-p 240mVp-p
Độ ổn định của dây đầu vào ±1% ±1% ±1% ±1%
Ổn định tải ±1% ±1% ±1% ±1%
Hiệu quả 78% 83% 84% 85%
Phạm vi điều chỉnh cho điện áp DC ±10% ±10% ±10% ±10%
Dải điện áp đầu vào 85~264VAC/120~370VDC; 47~63Hz
Tác động hiện tại Cold start current: 25A/115VAC; 45A/230VAC
Bảo vệ quá tải 110%~150% cut off the output, automatic recovery
Bảo vệ quá áp 115%~140% rated output power. Protection type: Hiccups mode, recovers automatically after fault condition is removed
Thiết lập, tăng, giữ thời gian 2000ms, 80ms/230VAC; 2000ms, 80ms/115VAC (at full load)
Chịu được điện áp I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute
Điện trở cách ly I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC / 25℃ / 70%RH
Nhiệt độ làm việc -20℃~+70℃
Kích thước 17.5×90×54.5mm
Cân nặng 0.08kg
đóng gói 42.5×34×19.5CM/140PCS/12kg

Why choose HDR-15?

Defined mechanical envelope

The stated body dimensions are 17.5×90×54.5mm. Use these dimensions to allocate panel space, then check the complete drawing, terminal access and nearby equipment.

Distinct single-output versions

The listed versions are HDR-15-5, HDR-15-12, HDR-15-24, HDR-15-48. Each is a single-output model, not a simultaneous multi-voltage supply. Match the selected version to the equipment input.

Documented input coverage

The specified input ranges are 85–264VAC and 120–370VDC, with an AC frequency range of 47–63Hz. Confirm the actual source, wiring requirements and supplied revision.

Defined overload recovery

Overload protection is listed at 110%~150% with output cut-off and automatic recovery. Coordinate the supply and downstream load so a fault response is not treated as normal continuous operation.

Key Features of the WEHO HDR-15W Industrial Slim DIN Rail Power Supply

  • Model-specific output information: HDR-15-5: 5V 0~2.4A; HDR-15-12: 12V 0~1.25A; HDR-15-24: 24V 0~0.63A; HDR-15-48: 48V 0~0.32A. Keep each current range with its stated model; the family designation does not establish one continuous-power rating for every output option.
  • Regulation and adjustment: Line regulation and load regulation are each listed as ±1%. The DC voltage adjustment range is ±10%; confirm the connected electronics input limits before adjusting the setting.
  • Noise and efficiency data for selection: Ripple/noise: HDR-15-5: 80mVp-p; HDR-15-12: 120mVp-p; HDR-15-24: 150mVp-p; HDR-15-48: 240mVp-p. Efficiency: HDR-15-5: 78%; HDR-15-12: 83%; HDR-15-24: 84%; HDR-15-48: 85%. Use the selected model figures in the load noise and power-budget assessment.
  • Model-specific terminal information: Pin 1: +V; pin 2: -V; pin 3: AC/N; pin 4: AC/L. The drawing specifies TS35/7.5 or TS35/15 DIN rails. Follow the complete drawing and the installation electrical-safety requirements.

Ứng dụng công nghiệp

These are potential integration roles, not customer-installation claims. Match the selected voltage, steady-state current, start-up demand and environment before selection.

Access-control electronics

Use a voltage-compatible HDR-15 version for reader, controller or interface electronics inside a protected access-control panel. Assess door strikes, motors and pulsed loads separately; a matching nominal voltage alone does not establish suitability.

Process sensing and monitoring

Provide local DC power to compatible sensor interfaces, monitoring modules or indication electronics with the selected HDR-15 voltage. Check steady-state and start-up demand and compare ripple/noise with the measurement-system requirements.

Building-automation interfaces

Supply compatible zone-controller or building-management interface electronics in a protected panel. Check the HDR-15 mechanical envelope, panel temperature and load input limits; the supply alone does not establish outdoor or system-level approval.

Industrial communications equipment

Power compatible gateways, serial-interface modules or local communications electronics that accept the selected HDR-15 DC input. Verify the whole load budget and start-up conditions; this selection does not add PoE, backup or UPS functions.

Model Selection & Specifications (HDR-15 Series)

  • HDR-15-5: 5V 0~2.4A
  • HDR-15-12: 12V 0~1.25A
  • HDR-15-24: 24V 0~0.63A
  • HDR-15-48: 48V 0~0.32A

WEHO HDR-15W Industrial AC DC 5V 12V 24V 48V Slim DIN Rail Power Supply  title=

Typical service conditions

Panel space and mechanical fit

Plan around the 17.5×90×54.5mm body and 0.08kg stated weight. The drawing specifies TS35/7.5 or TS35/15 DIN rails. Allow for wiring and the surrounding equipment; the body dimensions are not a universal clearance specification.

Input and terminal checks

Check the actual supply against 85–264VAC or 120–370VDC and the 47–63Hz AC range. Pin 1: +V; pin 2: -V; pin 3: AC/N; pin 4: AC/L. Confirm DC-input wiring for the selected revision rather than assuming AC labels alone define every DC installation.

Temperature and load planning

The working-temperature range is -20°C to +70°C. Assess the real enclosure, airflow and selected output load; the stated temperature range alone does not establish full output at every ambient temperature.

Start-up and fault coordination

Timing information is listed as 2000ms, 80ms/230VAC; 2000ms, 80ms/115VAC (at full load). Cold-start current is 25A/115VAC; 45A/230VAC. Keep these figures with their stated input conditions when coordinating upstream protection and downstream start-up.

HDR-15 technical FAQs

Which DC output models are listed for HDR-15?

The listed models are HDR-15-5, HDR-15-12, HDR-15-24, HDR-15-48, with nominal outputs of 5V, 12V, 24V, 48V respectively. Each is a single-output version.

What current ratings are listed for HDR-15?

HDR-15-5: 5V 0~2.4A; HDR-15-12: 12V 0~1.25A; HDR-15-24: 24V 0~0.63A; HDR-15-48: 48V 0~0.32A. Keep each current range with its exact output model and assess the actual load and operating conditions.

What input-voltage and frequency ranges are specified?

The input-voltage ranges are 85–264VAC and 120–370VDC. The AC frequency range is 47–63Hz. Check the selected unit and installation requirements before connection.

What line-regulation and load-regulation figures are listed?

Line regulation and load regulation are each listed as ±1% for every output version in this family.

What DC voltage adjustment range is listed?

The listed DC voltage adjustment range is ±10% for each version. Verify the connected equipment input limits before changing the setting.

What ripple/noise values are listed for HDR-15?

HDR-15-5: 80mVp-p; HDR-15-12: 120mVp-p; HDR-15-24: 150mVp-p; HDR-15-48: 240mVp-p. Confirm any application-specific measurement conditions separately.

What efficiency values are listed for HDR-15?

HDR-15-5: 78%; HDR-15-12: 83%; HDR-15-24: 84%; HDR-15-48: 85%. Use the figure for the selected voltage version.

What cold-start current is specified?

The listed cold-start current is 25A/115VAC; 45A/230VAC. Keep each value tied to its stated AC input when assessing upstream protection.

How is overload recovery specified?

The overload range is 110%~150%, with output cut-off and automatic recovery. Do not treat the protection threshold as a normal continuous operating rating.

What timing information is provided?

The timing row lists 2000ms, 80ms/230VAC; 2000ms, 80ms/115VAC (at full load). A separate third hold-up-time value is not printed in that row.

What working-temperature range and dimensions are stated for HDR-15?

The stated working-temperature range is -20°C to +70°C. Body dimensions are 17.5×90×54.5mm and weight is 0.08kg. Verify thermal performance with the actual load and enclosure rather than assuming full output at every temperature.

Which terminal assignments are shown for HDR-15?

Pin 1: +V; pin 2: -V; pin 3: AC/N; pin 4: AC/L. The drawing specifies TS35/7.5 or TS35/15 DIN rails. Use the complete drawing and applicable installation instructions for final integration.

Sản phẩm Power Supply nào tốt nhất cho doanh nghiệp của bạn?

Thúc đẩy hoạt động kinh doanh của bạn với các sản phẩm bộ nguồn chất lượng WEHO.

Hỏi chuyên gia
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.