{"id":20729,"date":"2026-11-03T10:08:18","date_gmt":"2026-11-03T02:08:18","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/tx4w-panel-retrofit-cutout-service-envelope\/"},"modified":"2026-11-03T10:08:18","modified_gmt":"2026-11-03T02:08:18","slug":"tx4w-panel-retrofit-cutout-service-envelope","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/vi\/news\/tx4w-panel-retrofit-cutout-service-envelope\/","title":{"rendered":"TX4-W Panel Retrofit: Separate the Front Size, Cutout and Service Envelope"},"content":{"rendered":"<figure class=\"hero\"><a href=\"https:\/\/www.wehopower.com\/vi\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/hero-4.webp\" alt=\"Empty sample-panel opening beside an installed TX4-W front, with a caliper resting on the workbench.\" fetchpriority=\"high\" title=\"\"><\/a><figcaption>A separate sample opening and the installed TX4-W front are evaluated as different interfaces. The caliper is ready on the workbench; no measurement or rear fit is demonstrated. AI-assisted illustration.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-1.png\">View original product image<\/a><\/figure>\n<p><strong>The 96 \u00d748 mm front size of a TX4-W is not the size of the panel opening.<\/strong> The current product table and TX4 manual give a 92 \u00d745 mm cutout for this horizontal form. A retrofit must also allow the rear body, retention arrangement, terminals and maintenance access; matching the front outline alone is insufficient.<\/p>\n<p>This guide helps an OEM panel designer decide whether a proposed existing opening and enclosure layout can proceed to a mechanical trial. It keeps a documented dimension separate from an unverified installation assumption.<\/p>\n<nav class=\"toc\" aria-label=\"On this page\">\n<ol>\n<li><a href=\"#three-envelopes\">List three different envelopes on the drawing<\/a><\/li>\n<li><a href=\"#opening-check\">Measure the existing opening before cutting metal<\/a><\/li>\n<li><a href=\"#front-coverage\">Front overlap is a geometric check, not a seal rating<\/a><\/li>\n<li><a href=\"#depth-conflict\">Resolve the depth source conflict before mechanical release<\/a><\/li>\n<li><a href=\"#door-and-service\">Check the enclosure in operating and service positions<\/a><\/li>\n<li><a href=\"#release-package\">Release a drawing that the next fabricator can repeat<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"three-envelopes\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">M\u1ee5c l\u1ee5c<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Chuy\u1ec3n \u0111\u1ed5i<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/vi\/news\/tx4w-panel-retrofit-cutout-service-envelope\/#List_three_different_envelopes_on_the_drawing\" >List three different envelopes on the drawing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/vi\/news\/tx4w-panel-retrofit-cutout-service-envelope\/#Measure_the_existing_opening_before_cutting_metal\" >Measure the existing opening before cutting metal<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/vi\/news\/tx4w-panel-retrofit-cutout-service-envelope\/#Front_overlap_is_a_geometric_check_not_a_seal_rating\" >Front overlap is a geometric check, not a seal rating<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/vi\/news\/tx4w-panel-retrofit-cutout-service-envelope\/#Resolve_the_depth_source_conflict_before_mechanical_release\" >Resolve the depth source conflict before mechanical release<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/vi\/news\/tx4w-panel-retrofit-cutout-service-envelope\/#Check_the_enclosure_in_operating_and_service_positions\" >Check the enclosure in operating and service positions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/vi\/news\/tx4w-panel-retrofit-cutout-service-envelope\/#Release_a_drawing_that_the_next_fabricator_can_repeat\" >Release a drawing that the next fabricator can repeat<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/vi\/news\/tx4w-panel-retrofit-cutout-service-envelope\/#TX4-W_retrofit_fit_record\" >TX4-W retrofit fit record<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/vi\/news\/tx4w-panel-retrofit-cutout-service-envelope\/#Sources_and_further_reading\" >Sources and further reading<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"List_three_different_envelopes_on_the_drawing\"><\/span>List three different envelopes on the drawing<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>c\u00e1c <a href=\"https:\/\/www.wehopower.com\/vi\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\">WEHO TX4-W page<\/a> identifies the horizontal 96 \u00d748 mm front and 92 \u00d745 mm opening. The <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/11\/TX4.pdf\">TX4 230808EN manual<\/a> repeats those opening dimensions in its size table. They describe different parts of the installation: the visible front covers the panel; the body passes through the opening; rear connections occupy additional space inside.<\/p>\n<p>Draw the front footprint, actual cutout and rear service envelope as separate layers. Do not rotate a tall TX4-H outline and assume the retention or terminal arrangement is unchanged. The W size is a distinct documented form, and the applicable complete model and revision must remain attached to the drawing.<\/p>\n<\/section>\n<section id=\"opening-check\">\n<h2><span class=\"ez-toc-section\" id=\"Measure_the_existing_opening_before_cutting_metal\"><\/span>Measure the existing opening before cutting metal<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Record width and height at multiple positions, corner geometry, burrs, panel thickness and the location of adjacent controls. The nominal 92 \u00d745 mm statement is not a complete tolerance specification for every fabrication process. Obtain the applicable installation drawing and panel-thickness\/retention requirements before releasing the cutout.<\/p>\n<p>For a hypothetical existing opening of 90.0 \u00d744.0 mm, reaching the nominal 92 \u00d745 mm sizes requires 2.0 mm additional total width and 1.0 mm additional total height. If centered perfectly, that is 1.0 mm per vertical side and 0.5 mm per horizontal side. This simple arithmetic does not establish acceptable edge tolerances or authorize field machining near live equipment.<\/p>\n<\/section>\n<section id=\"front-coverage\">\n<h2><span class=\"ez-toc-section\" id=\"Front_overlap_is_a_geometric_check_not_a_seal_rating\"><\/span>Front overlap is a geometric check, not a seal rating<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"fig-diagram\" class=\"diagram\"><img decoding=\"async\" class=\"technical-desktop\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-4.svg\" alt=\"TX4-W front and cutout dimensions separated from the unresolved rear service envelope\" loading=\"lazy\" title=\"\"><img decoding=\"async\" class=\"technical-mobile\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-mobile-4.svg\" alt=\"TX4-W front and cutout dimensions separated from the unresolved rear service envelope\" loading=\"lazy\" title=\"\"><figcaption>Nominal source dimensions and calculated overlap;not a fabrication or mounting drawing.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-4.svg\">Open full-size technical illustration<\/a><\/figure>\n<p>For the listed 96 \u00d748 mm front over a nominal 92 \u00d745 mm opening, centered arithmetic overlap is <strong>(96\u221292)\/2=2 mm<\/strong> on each left\/right side and <strong>(48\u221245)\/2=1.5 mm<\/strong> at top\/bottom. An off-center or oversize opening consumes that coverage unevenly.<\/p>\n<p>Do not infer sealing, structural retention or a permissible hole tolerance from those overlap numbers. A gasket and clamp arrangement, if applicable, must be supported by the exact model&#8217;s documentation. The front photograph can identify the W layout but cannot prove an unseen clip is engaged.<\/p>\n<\/section>\n<section id=\"depth-conflict\">\n<h2><span class=\"ez-toc-section\" id=\"Resolve_the_depth_source_conflict_before_mechanical_release\"><\/span>Resolve the depth source conflict before mechanical release<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The TX4 product-page features state 75 mm depth, while the TX4 manual dimension table shows D=50 mm for the W form and the broader catalog also describes 50 mm depth. These inspected sources do not establish which revision or dimension convention accounts for the difference. Do not choose 50 mm because it fits the enclosure better, or add 25 mm to an invented connector dimension and declare the conflict solved.<\/p>\n<p>Request the current exact-model outline and identify the dimension reference surfaces. Then add the documented terminal projection, connector access, wire bend and maintenance withdrawal needs for the actual configuration. A body-depth number is not the full required distance to a closed rear panel or cable duct.<\/p>\n<\/section>\n<section id=\"door-and-service\">\n<h2><span class=\"ez-toc-section\" id=\"Check_the_enclosure_in_operating_and_service_positions\"><\/span>Check the enclosure in operating and service positions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Model the door closed, open and at the intended service angle. Internal conductors should not pull terminals as the door moves, cross sharp edges or block adjacent devices. Reserve space for the actual terminal access and for removal using the approved method. Do not treat an empty enclosure rendering as proof of serviceability after all wiring is installed.<\/p>\n<p>Check whether adjacent controls or latches obstruct the bezel or retention access. The manual includes panel spacing information, which should be read with its figure and applicable revision rather than converted into a universal gap from a text extraction alone. Use a physical sample or accurately documented model for the final fit comparison.<\/p>\n<\/section>\n<section id=\"release-package\">\n<h2><span class=\"ez-toc-section\" id=\"Release_a_drawing_that_the_next_fabricator_can_repeat\"><\/span>Release a drawing that the next fabricator can repeat<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"fig-original\" class=\"product-original\"><a href=\"https:\/\/www.wehopower.com\/vi\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-1.png\" alt=\"WEHO TX4-W front form with dual display and base model marking\" loading=\"lazy\" title=\"\"><\/a><figcaption>Official TX4-W front-form illustration. The complete order code and rear connection option must be confirmed separately.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-1.png\">View original image<\/a><\/figure>\n<p>Retain the exact TX4-W code, approved outline revision, measured panel condition and verified opening\/retention method. Include any adapter plate as its own engineered part with defined material and attachment. Do not hide an oversize hole behind a decorative product frame and describe it as the original installation.<\/p>\n<p>The fit record should state whether only the front appearance, a sample installation or the complete wired enclosure has been checked. Those are different levels of evidence. Final release requires the actual retention and service envelope to be verified, including the unresolved depth question.<\/p>\n<\/section>\n<section class=\"cta\">\n<p>Send <a href=\"https:\/\/www.wehopower.com\/vi\/contact\/\">WEHO<\/a> the full TX4-W requirement, existing cutout measurements, panel thickness, enclosure drawing and rear-space limit. Ask for the current matching outline and installation requirements before freezing the retrofit drawing.<\/p>\n<\/section>\n<section id=\"worksheet\" class=\"sheet\">\n<h2><span class=\"ez-toc-section\" id=\"TX4-W_retrofit_fit_record\"><\/span>TX4-W retrofit fit record<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"sheet-row\"><label>Full code<input aria-label=\"Full code\"><\/label><label>Outline revision<input aria-label=\"Outline revision\"><\/label><label>Panel thickness<input aria-label=\"Panel thickness\"><\/label><label>Existing opening<input aria-label=\"Existing opening\"><\/label><label>Adjacent components<input aria-label=\"Adjacent components\"><\/label><\/div>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Front<\/th>\n<th scope=\"col\">Footprint<\/th>\n<th scope=\"col\">Coverage<\/th>\n<th scope=\"col\">Alignment<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Cutout<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Width\/height\/corners<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Applicable tolerance<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Fabrication result<\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Rear<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Verified body reference<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Terminal\/wire\/service envelope<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Closed\/open door<\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Retention<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Documented method<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Sample fit<\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\">Release<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Blank project worksheet. Enter verified project data; example calculations above are not measurements.<\/p>\n<\/section>\n<section class=\"source-list\">\n<h2><span class=\"ez-toc-section\" id=\"Sources_and_further_reading\"><\/span>Sources and further reading<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><a href=\"https:\/\/www.wehopower.com\/vi\/product\/tx4-series-tx4-w-economic-dual-display-pid-temperature-controller\/\">WEHO TX4-W size table<\/a><\/li>\n<li><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2023\/11\/TX4.pdf\">TX4 230808EN dimensions<\/a><\/li>\n<\/ol>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Check TX4-W front dimensions, panel cutout and rear service space separately. Build a retrofit drawing instead of selecting an opening from bezel size.<\/p>","protected":false},"author":2,"featured_media":20701,"parent":0,"menu_order":176,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-20729","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news\/20729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/comments?post=20729"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news\/20729\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/media\/20701"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/media?parent=20729"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news_category?post=20729"}],"curies":[{"name":"wp c\u1ee7a t\u00f4i","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}