{"id":20999,"date":"2026-11-07T10:07:38","date_gmt":"2026-11-07T02:07:38","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/dc-backup-output-does-not-prove-mains-present\/"},"modified":"2026-11-07T10:07:38","modified_gmt":"2026-11-07T02:07:38","slug":"dc-backup-output-does-not-prove-mains-present","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/vi\/news\/dc-backup-output-does-not-prove-mains-present\/","title":{"rendered":"A DC Backup Output Can Stay Healthy After Mains Fails: Define Separate Status Evidence"},"content":{"rendered":"<figure class=\"hero\"><a href=\"https:\/\/www.wehopower.com\/vi\/product\/ups-35w-ac-to-dc-single-output-power-supply-for-battery-charge\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/hero-27.webp\" alt=\"A DC Backup Output Can Stay Healthy After Mains Fails: Define Separate Status Evidence  title=\" fetchpriority=\"high\" a dc backup output can stay healthy after mains fails: define separate status evidence title=\"\"><\/a><figcaption>Backup-status requirements review using the original SC-35-12 component and factory harness. The board separates mains availability, DC receiver condition and battery readiness. The component is disconnected; no operating backup test or alarm interface is shown. AI-assisted illustration.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-20.jpg\">View original product image<\/a><\/figure>\n<p><strong>A healthy DC output is not proof that AC mains is present when a battery can continue supplying the load.<\/strong> Define mains, output and battery observations separately before choosing the controller\u2019s alarm logic. A green output indicator alone cannot identify which energy source is carrying the circuit.<\/p>\n<p>This guide helps an OEM prepare the status requirements for an SC-35 family candidate. The available page describes AC\/battery backup, but it is not sufficient evidence to assign an undocumented alarm contact or exact switching time.<\/p>\n<nav class=\"toc\" aria-label=\"On this page\">\n<ol>\n<li><a href=\"#state-the-three-questions\">State three different questions before naming an alarm<\/a><\/li>\n<li><a href=\"#write-status-matrix\">Write the required status matrix before selecting interfaces<\/a><\/li>\n<li><a href=\"#verify-interface-type\">Verify what any proposed status interface actually reports<\/a><\/li>\n<li><a href=\"#define-timing\">Define alarm timing independently from backup continuity<\/a><\/li>\n<li><a href=\"#test-and-handoff\">Test each required state and preserve the observation point<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"state-the-three-questions\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">M\u1ee5c l\u1ee5c<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Chuy\u1ec3n \u0111\u1ed5i<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/vi\/news\/dc-backup-output-does-not-prove-mains-present\/#State_three_different_questions_before_naming_an_alarm\" >State three different questions before naming an alarm<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/vi\/news\/dc-backup-output-does-not-prove-mains-present\/#Write_the_required_status_matrix_before_selecting_interfaces\" >Write the required status matrix before selecting interfaces<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/vi\/news\/dc-backup-output-does-not-prove-mains-present\/#Verify_what_any_proposed_status_interface_actually_reports\" >Verify what any proposed status interface actually reports<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/vi\/news\/dc-backup-output-does-not-prove-mains-present\/#Define_alarm_timing_independently_from_backup_continuity\" >Define alarm timing independently from backup continuity<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/vi\/news\/dc-backup-output-does-not-prove-mains-present\/#Test_each_required_state_and_preserve_the_observation_point\" >Test each required state and preserve the observation point<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/vi\/news\/dc-backup-output-does-not-prove-mains-present\/#Backup_status_acceptance_record\" >Backup status acceptance record<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/vi\/news\/dc-backup-output-does-not-prove-mains-present\/#Sources_and_further_reading\" >Sources and further reading<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"State_three_different_questions_before_naming_an_alarm\"><\/span>State three different questions before naming an alarm<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>First: is the intended AC source available at the monitored point? Second: is the DC output within the receiver\u2019s required limits? Third: is the battery connected and able to support the required duty? These conditions can differ. A system can have acceptable output with failed mains, or present mains with an output problem.<\/p>\n<p>c\u00e1c <a href=\"https:\/\/www.wehopower.com\/vi\/product\/ups-35w-ac-to-dc-single-output-power-supply-for-battery-charge\/\">WEHO SC-35 page<\/a> lists battery backup behavior and two output variants. Its table contains a duplicated channel label in the 12 V column. Do not repair that text by assumption, or use a family photograph to infer the exact variant and all status functions.<\/p>\n<figure id=\"fig-original\" class=\"product-original\"><a href=\"https:\/\/www.wehopower.com\/vi\/product\/ups-35w-ac-to-dc-single-output-power-supply-for-battery-charge\/\"><img decoding=\"async\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-20.jpg\" alt=\"A DC Backup Output Can Stay Healthy After Mains Fails: Define Separate Status Evidence  title=\" loading=\"lazy\" a dc backup output can stay healthy after mains fails: define separate status evidence title=\"\"><\/a><figcaption>Manufacturer photograph with an SC-35-12 label and supplied leads. The image does not identify an alarm interface or prove backup readiness.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/original-20.jpg\">View original image<\/a><\/figure>\n<\/section>\n<section id=\"write-status-matrix\">\n<h2><span class=\"ez-toc-section\" id=\"Write_the_required_status_matrix_before_selecting_interfaces\"><\/span>Write the required status matrix before selecting interfaces<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Defined state<\/th>\n<th scope=\"col\">AC observation<\/th>\n<th scope=\"col\">DC observation<\/th>\n<th scope=\"col\">What must remain distinct<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Normal supplied operation<\/td>\n<td>Source available at chosen point<\/td>\n<td>Within receiver limits<\/td>\n<td>Battery readiness still needs evidence<\/td>\n<\/tr>\n<tr>\n<td>Mains absent, battery supporting<\/td>\n<td>Source absent<\/td>\n<td>May remain within limits<\/td>\n<td>Report AC loss without declaring DC failure<\/td>\n<\/tr>\n<tr>\n<td>Output fault with mains present<\/td>\n<td>Source may be available<\/td>\n<td>Outside receiver limits<\/td>\n<td>Investigate output\/load path<\/td>\n<\/tr>\n<tr>\n<td>Battery disconnected<\/td>\n<td>May be available<\/td>\n<td>May appear normal while mains is present<\/td>\n<td>Normal DC does not prove backup readiness<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>This is a requirement matrix. It does not assert that the SC-35 has a separate hardware output for each row. Obtain the supplied revision\u2019s actual signal definitions and decide what additional approved monitoring is needed.<\/p>\n<figure id=\"fig-diagram\" class=\"diagram\"><img decoding=\"async\" class=\"technical-desktop\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-27.svg\" alt=\"A DC Backup Output Can Stay Healthy After Mains Fails: Define Separate Status Evidence  title=\" loading=\"lazy\" a dc backup output can stay healthy after mains fails: define separate status evidence title=\"\"><img decoding=\"async\" class=\"technical-mobile\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-mobile-27.svg\" alt=\"A DC Backup Output Can Stay Healthy After Mains Fails: Define Separate Status Evidence  title=\" loading=\"lazy\" a dc backup output can stay healthy after mains fails: define separate status evidence title=\"\"><figcaption>Functional status requirements; no SC-35 alarm interface or transfer-time claim is assigned.<\/figcaption><a class=\"original-link\" href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/diagram-27.svg\">Open full-size technical illustration<\/a><\/figure>\n<\/section>\n<section id=\"verify-interface-type\">\n<h2><span class=\"ez-toc-section\" id=\"Verify_what_any_proposed_status_interface_actually_reports\"><\/span>Verify what any proposed status interface actually reports<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Ask for the signal\u2019s reference point, electrical type, active state, thresholds, hysteresis, timing and behavior when the supply or monitoring controller loses power. An active voltage output, an open collector and a floating relay contact are different interfaces. Their names cannot be exchanged in the drawing.<\/p>\n<p>As an external example, <a href=\"https:\/\/www.meanwell.com\/Upload\/PDF\/DRC-40\/DRC-40-SPEC.PDF\" target=\"_blank\" rel=\"noopener\">Mean Well\u2019s DRC-40 specification<\/a> separately documents AC OK and battery-low signaling. That document illustrates the evidence needed for that product; its pins, levels and thresholds do not apply to the WEHO SC-35.<\/p>\n<p>If an external mains monitor is proposed, define which point it observes. Voltage present upstream of a branch protective device may not establish AC at the supply input. Select and install any mains interface through the qualified equipment design, not an improvised connection to a controller input.<\/p>\n<\/section>\n<section id=\"define-timing\">\n<h2><span class=\"ez-toc-section\" id=\"Define_alarm_timing_independently_from_backup_continuity\"><\/span>Define alarm timing independently from backup continuity<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A load may ride through an AC interruption while the alarm is intentionally delayed. Conversely, the alarm may arrive after the receiver has already reset. Record the required detection time, nuisance-alarm filtering and controller reaction separately from the DC output interruption criterion.<\/p>\n<p>For an illustrative requirement, a project might permit an AC-loss alarm after a 200 ms persistence interval but require a different receiver continuity limit. These are project-defined requirements, not SC-35 timing specifications. The validation plan must measure the actual alarm and receiver behavior rather than infer either from a marketing phrase.<\/p>\n<\/section>\n<section id=\"test-and-handoff\">\n<h2><span class=\"ez-toc-section\" id=\"Test_each_required_state_and_preserve_the_observation_point\"><\/span>Test each required state and preserve the observation point<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use an authorized sequence to exercise the defined states and recovery. Record AC at the intended observation point, receiver voltage and each actual status interface using suitable isolated measurement methods. Do not use the article as a live-wiring or battery-disconnection procedure.<\/p>\n<p>Give operations a record that explains each displayed alarm and its limitation. For example, \u201cDC within limit\u201d should not be renamed \u201cmains healthy\u201d or \u201cbattery ready.\u201d Recheck the matrix when a controller, status module, supply variant or battery arrangement changes, so a reassuring display continues to mean exactly what the evidence supports.<\/p>\n<\/section>\n<section class=\"cta\">\n<p>Send WEHO the proposed <a href=\"https:\/\/www.wehopower.com\/vi\/product\/ups-35w-ac-to-dc-single-output-power-supply-for-battery-charge\/\">SC-35-12 backup application<\/a> with the required AC\/DC\/battery state matrix, observation points, alarm timing and actual controller interfaces. Request the supplied revision\u2019s status-signal definitions and channel identification; select any additional monitoring only after those capabilities are established.<\/p>\n<\/section>\n<section id=\"worksheet\" class=\"sheet\">\n<h2><span class=\"ez-toc-section\" id=\"Backup_status_acceptance_record\"><\/span>Backup status acceptance record<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"sheet-row\"><label>Supply revision and variant<input aria-label=\"Supply revision and variant\"><\/label><label>Monitoring observation points<input aria-label=\"Monitoring observation points\"><\/label><label>Controller revision<input aria-label=\"Controller revision\"><\/label><label>Approved test sequence<input aria-label=\"Approved test sequence\"><\/label><\/div>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Required state<\/th>\n<th scope=\"col\">Actual measured evidence<\/th>\n<th scope=\"col\">Interface definition<\/th>\n<th scope=\"col\">Timing requirement\/result<\/th>\n<th scope=\"col\">Meaning shown to operator<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<\/tr>\n<tr>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<td contenteditable=\"true\" aria-label=\"Worksheet cell\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Blank project worksheet. Enter verified project data; example calculations above are not measurements.<\/p>\n<\/section>\n<section class=\"source-list\">\n<h2><span class=\"ez-toc-section\" id=\"Sources_and_further_reading\"><\/span>Sources and further reading<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><a href=\"https:\/\/www.wehopower.com\/vi\/product\/ups-35w-ac-to-dc-single-output-power-supply-for-battery-charge\/\">WEHO SC-35 product information<\/a><\/li>\n<li><a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2021\/11\/SC-35ok.pdf\">WEHO SC-35 specification<\/a><\/li>\n<li><a href=\"https:\/\/www.meanwell.com\/Upload\/PDF\/DRC-40\/DRC-40-SPEC.PDF\" target=\"_blank\" rel=\"noopener\">Mean Well DRC-40 model-specific status documentation<\/a><\/li>\n<\/ol>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Design a status matrix that separates mains presence, DC output and battery condition for a candidate SC-35 backup supply without inventing an alarm interface.<\/p>","protected":false},"author":2,"featured_media":20971,"parent":0,"menu_order":86,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-20999","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news\/20999","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/comments?post=20999"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news\/20999\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/media\/20971"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/media?parent=20999"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news_category?post=20999"}],"curies":[{"name":"wp c\u1ee7a t\u00f4i","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}