{"id":23269,"date":"2026-11-20T10:04:17","date_gmt":"2026-11-20T02:04:17","guid":{"rendered":"https:\/\/www.wehopower.com\/news\/emi-detector-quasi-peak-average-limits\/"},"modified":"2026-11-20T10:04:17","modified_gmt":"2026-11-20T02:04:17","slug":"emi-detector-quasi-peak-average-limits","status":"publish","type":"news","link":"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/","title":{"rendered":"EMI Quasi-Peak and Average Detectors: Compare the Right Limits"},"content":{"rendered":"<div class=\"weho-blog\">\n<p>An EMI level is interpretable only with its detector, bandwidth, measurement conditions and applicable limit. A lower average-detector reading can still exceed its own limit while a higher quasi-peak reading remains below a different limit at the same frequency.<\/p>\n<p><strong>Key engineering takeaways<\/strong><\/p>\n<ul>\n<li>Associate every reported level with its detector.<\/li>\n<li>Compare quasi-peak and average results to their respective limits.<\/li>\n<li>Preserve timing, bandwidth and operating-state evidence.<\/li>\n<li>Treat a pre-scan as evidence within its actual scope.<\/li>\n<\/ul>\n<figure class=\"article-figure hero\" data-asset=\"H11-hero\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/vi\/product\/ndr-dinrail-120w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"NDR-120-24 details\"><img fetchpriority=\"high\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/5c902365198df58f-ndr-120-24-application.webp\" alt=\"NDR-120-24 product installed in an industrial application scene with original housing and label details.\" width=\"1200\" height=\"675\" loading=\"eager\" decoding=\"async\" title=\"\"><\/a><figcaption>NDR-120-24 in an application illustration, not a customer installation photo. Scene created with AI assistance. The image does not establish EMI emissions or compliance with any limit. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/c098f4405daa5c57-ndr-120-24-application-master.webp\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<nav class=\"table-of-contents\" aria-label=\"Article contents\">\n<details open>\n<summary>On this page<\/summary>\n<ol>\n<li><a href=\"#what-should-the-oem-learn-from-a-detector-comparison\">What should the OEM learn from a detector comparison?<\/a><\/li>\n<li><a href=\"#why-can-the-same-signal-produce-several-reported-levels\">Why can the same signal produce several reported levels?<\/a><\/li>\n<li><a href=\"#a-hypothetical-report-with-opposite-comparison-outcomes\">A hypothetical report with opposite comparison outcomes<\/a><\/li>\n<li><a href=\"#what-can-a-peak-pre-scan-tell-the-reviewer\">What can a peak pre-scan tell the reviewer?<\/a><\/li>\n<li><a href=\"#why-do-time-and-operating-state-matter\">Why do time and operating state matter?<\/a><\/li>\n<li><a href=\"#build-a-detector-specific-review-record\">Build a detector-specific review record<\/a><\/li>\n<li><a href=\"#prepare-an-ndr-120-24-emc-evidence-enquiry\">Prepare an NDR-120-24 EMC evidence enquiry<\/a><\/li>\n<li><a href=\"#engineering-faq\">Engineering FAQ<\/a><\/li>\n<\/ol>\n<\/details>\n<\/nav>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">M\u1ee5c l\u1ee5c<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Chuy\u1ec3n \u0111\u1ed5i<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#What_should_the_OEM_learn_from_a_detector_comparison\" >What should the OEM learn from a detector comparison?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#Why_can_the_same_signal_produce_several_reported_levels\" >Why can the same signal produce several reported levels?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#A_hypothetical_report_with_opposite_comparison_outcomes\" >A hypothetical report with opposite comparison outcomes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#What_can_a_peak_pre-scan_tell_the_reviewer\" >What can a peak pre-scan tell the reviewer?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#Why_do_time_and_operating_state_matter\" >Why do time and operating state matter?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#Build_a_detector-specific_review_record\" >Build a detector-specific review record<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#Prepare_an_NDR-120-24_EMC_evidence_enquiry\" >Prepare an NDR-120-24 EMC evidence enquiry<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#Engineering_FAQ\" >Engineering FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#Can_an_average_result_be_lower_yet_fail_its_comparison\" >Can an average result be lower yet fail its comparison?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#Is_an_average_of_displayed_dB_values_an_EMI_average_result\" >Is an average of displayed dB values an EMI average result?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#Does_a_peak_pre-scan_crossing_automatically_prove_quasi-peak_failure\" >Does a peak pre-scan crossing automatically prove quasi-peak failure?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.wehopower.com\/vi\/news\/emi-detector-quasi-peak-average-limits\/#Are_the_60_and_50_dB%C2%B5V_example_lines_legal_limits_for_this_supply\" >Are the 60 and 50 dB\u00b5V example lines legal limits for this supply?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 id=\"what-should-the-oem-learn-from-a-detector-comparison\"><span class=\"ez-toc-section\" id=\"What_should_the_OEM_learn_from_a_detector_comparison\"><\/span>What should the OEM learn from a detector comparison?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The useful engineering decision is whether the report contains the required measurement and correct comparison for the intended equipment assessment. A screenshot showing one trace below one line cannot answer every conducted-emission question. The receiver configuration and the selected requirement must remain identifiable.<\/p>\n<p>For an <a href=\"https:\/\/www.wehopower.com\/vi\/product\/ndr-dinrail-120w-ac-to-dc-single-output-switching-power-supply\/\">NDR-120-24 equipment review<\/a>, identify the actual supply, host equipment, load and tested ports. A component photograph does not establish an equipment emission result. Neither an article example nor a family description proves that the complete assembly satisfies a particular standard.<\/p>\n<p>The existing <a href=\"https:\/\/www.wehopower.com\/vi\/news\/emc-class-a-vs-class-b-audit-the-conducted-emission-report-not-the-label\/\">conducted-emission report review<\/a> addresses report scope and classification evidence. This article examines the narrower detector-to-limit relationship. Keep the applicable standard, edition and laboratory decision rule with the real assessment instead of selecting a convenient limit from an unrelated example.<\/p>\n<h2 id=\"why-can-the-same-signal-produce-several-reported-levels\"><span class=\"ez-toc-section\" id=\"Why_can_the_same_signal_produce_several_reported_levels\"><\/span>Why can the same signal produce several reported levels?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An EMI receiver processes the incoming signal through a defined measurement chain. The detector determines how that signal is weighted over time. Peak, quasi-peak and average labels therefore describe different measurement operations rather than interchangeable names for one numerical result.<\/p>\n<p><a href=\"https:\/\/cdn.rohde-schwarz.com\/pws\/campaigns\/rsa\/Rohde_Schwarz_Precompliance_EMI_Debug_AppNote_V1.pdf\" target=\"_blank\" rel=\"noopener\">Rohde &amp; Schwarz&#39;s precompliance application note<\/a> describes detector modes and defined bandwidths as part of EMI measurement. Record the actual settings used for each result. Do not compare two numbers as if detector selection were the only change when their bandwidth, observation time or equipment state also differs.<\/p>\n<p>Quasi-peak weighting responds to pulse behavior through defined charging and discharging characteristics. An EMI average measurement addresses a different weighting operation. Neither can be reconstructed reliably by reading a peak marker and subtracting a generic fixed number of decibels.<\/p>\n<p>An ordinary arithmetic average of displayed decibel samples is also not automatically the specified EMI average detector. Preserve the exact receiver mode and its applicable documentation. A software trace labeled \u201caverage\u201d needs enough configuration detail to establish which averaging operation actually produced it.<\/p>\n<h2 id=\"a-hypothetical-report-with-opposite-comparison-outcomes\"><span class=\"ez-toc-section\" id=\"A_hypothetical_report_with_opposite_comparison_outcomes\"><\/span>A hypothetical report with opposite comparison outcomes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Assume an engineering worksheet evaluates one frequency at 400 kHz using two <strong>invented illustrative limits<\/strong>: 60 dB\u00b5V for a quasi-peak result and 50 dB\u00b5V for an EMI average result. These are not quoted standard limits, WEHO results or a declaration of compliance. Ignore measurement uncertainty for this arithmetic demonstration only.<\/p>\n<p>Define worksheet margin as applicable limit minus reported level, so a positive number means the assumed level is below that assumed line. In case A, suppose the quasi-peak entry is 57 dB\u00b5V and the average entry is 52 dB\u00b5V. Their separate margins are 60 \u2212 57 = +3 dB and 50 \u2212 52 = \u22122 dB.<\/p>\n<p>The average level is numerically lower than the quasi-peak level, yet its comparison is unfavorable. Comparing 52 dB\u00b5V with the 60 dB\u00b5V quasi-peak line would incorrectly report an 8 dB margin. The correct hypothetical average comparison is 2 dB above its own 50 dB\u00b5V line.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Hypothetical record at 400 kHz<\/th>\n<th scope=\"col\">Quasi-peak: level \/ margin<\/th>\n<th scope=\"col\">Average: level \/ margin<\/th>\n<th scope=\"col\">Worksheet interpretation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Case A<\/td>\n<td>57 dB\u00b5V \/ +3 dB<\/td>\n<td>52 dB\u00b5V \/ \u22122 dB<\/td>\n<td>Average comparison exceeds its assumed line<\/td>\n<\/tr>\n<tr>\n<td>Case B<\/td>\n<td>59 dB\u00b5V \/ +1 dB<\/td>\n<td>48 dB\u00b5V \/ +2 dB<\/td>\n<td>Both assumed comparisons are below their lines<\/td>\n<\/tr>\n<tr>\n<td>Peak-only pre-scan<\/td>\n<td>No quasi-peak result supplied<\/td>\n<td>No average result supplied<\/td>\n<td>Do not invent the missing detector results<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure class=\"article-figure technical\" data-asset=\"H11-technical\">\n<div class=\"diagram-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering diagram\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/7ed5464c39bdf97b-emi-detector-limit-margins.svg\" alt=\"Hypothetical detector example compares quasi-peak and average levels with their separate limits and calculated margins.\" width=\"1200\" height=\"675\" decoding=\"async\" title=\"\"><\/div><figcaption>Conceptual Engineering Diagram. Invented levels and limits at 400 kHz illustrate separate comparisons; not standard limits, WEHO results or certification. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/7ed5464c39bdf97b-emi-detector-limit-margins.svg\" target=\"_blank\" rel=\"noopener\">Open full-size diagram<\/a><\/figcaption><p class=\"figure-help\">Swipe horizontally on a small screen, or open the full-size diagram.<\/p>\n<\/figure>\n<p>For a unit check, dB\u00b5V = 20 \u00d7 log10(V\/1 \u00b5V). The assumed 60 dB\u00b5V line corresponds to 1,000 \u00b5V, while 50 dB\u00b5V corresponds to about 316.2 \u00b5V. This conversion reinforces that the two lines represent different voltage levels; a single convenient threshold cannot be substituted for both.<\/p>\n<p>The table makes only the stated arithmetic comparisons. A real laboratory&#39;s uncertainty treatment and decision rule can affect its reported conclusion, particularly near a limit. A +1 dB worksheet margin is not by itself a certification result, nor proof that another configuration or operating mode will remain below a required line.<\/p>\n<h2 id=\"what-can-a-peak-pre-scan-tell-the-reviewer\"><span class=\"ez-toc-section\" id=\"What_can_a_peak_pre-scan_tell_the_reviewer\"><\/span>What can a peak pre-scan tell the reviewer?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A peak scan can help locate candidate frequencies for further evaluation. Its interpretation depends on the measurement method, bandwidth, signal behavior and the comparison being made. A peak crossing does not automatically establish the corresponding quasi-peak or average outcome.<\/p>\n<p><a href=\"https:\/\/www.keysight.com\/blogs\/en\/tech\/rfmw\/2018\/09\/21\/complete-your-emc-conducted-emissions-testing-in-just-7-steps\" target=\"_blank\" rel=\"noopener\">Keysight&#39;s conducted-emission example<\/a> explicitly pairs quasi-peak and average results with their respective lines. Its historical standard names and setup example are not adopted here as current requirements. Use the applicable method for the actual product and market, with a competent laboratory determining the required assessment.<\/p>\n<p>Conversely, a favorable preliminary trace cannot fill missing documentation. If a method permits a conservative detector substitution, record the basis, bandwidth and conditions that make it valid. Do not turn that conditional possibility into an unrestricted claim that any peak-only screen completes every EMI requirement.<\/p>\n<p>Retain scan and final-measurement states separately. A later measurement may use another detector or dwell time, while a development change may alter the equipment itself. A comparison is useful only when the record shows which differences were intentional and which quantities remain comparable.<\/p>\n<h2 id=\"why-do-time-and-operating-state-matter\"><span class=\"ez-toc-section\" id=\"Why_do_time_and_operating_state_matter\"><\/span>Why do time and operating state matter?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>An emission associated with a repeating machine action can be missed or weighted differently when observation does not capture the relevant behavior. Record the operating mode, load cycle and acquisition duration. A low reading from an idle state does not establish the result during the intended activity.<\/p>\n<p>c\u00e1c <a href=\"https:\/\/scdn.rohde-schwarz.com\/ur\/pws\/dl_downloads\/dl_common_library\/dl_manuals\/dl_user_manual\/ESPI_OperatingManual_en_02~1.pdf\" target=\"_blank\" rel=\"noopener\">Rohde &amp; Schwarz ESPI operating manual<\/a> distinguishes measurement time from settling behavior and explains detector-dependent timing. Those instructions are instrument-specific. They support checking the actual receiver and method rather than copying a universal dwell time into an OEM requirement.<\/p>\n<p>Also retain correction factors, connection configuration and overload checks required by the chosen method. A detector comparison does not repair an invalid input chain. Qualified personnel should manage mains-connected test equipment and its protective arrangements under the laboratory&#39;s procedures; this guide is a report-interpretation method, not a LISN wiring instruction.<\/p>\n<div class=\"table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable engineering table\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Record field<\/th>\n<th scope=\"col\">Required relationship<\/th>\n<th scope=\"col\">Useful verification<\/th>\n<th scope=\"col\">Unresolved shortcut<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Detector and result<\/td>\n<td>Each numerical entry names its exact detector<\/td>\n<td>Match report row to receiver configuration<\/td>\n<td>Unlabeled screenshot peak<\/td>\n<\/tr>\n<tr>\n<td>Limit and method<\/td>\n<td>Line matches detector, port and applicable assessment<\/td>\n<td>Check controlled method and edition<\/td>\n<td>One imported line used for every trace<\/td>\n<\/tr>\n<tr>\n<td>Bandwidth and timing<\/td>\n<td>Settings support the detector and signal behavior<\/td>\n<td>Review actual setup and observation interval<\/td>\n<td>Default settings accepted without scope<\/td>\n<\/tr>\n<tr>\n<td>Equipment state<\/td>\n<td>Result covers the identified configuration and activity<\/td>\n<td>Trace model, load, mode and revision<\/td>\n<td>Component label presented as system evidence<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"build-a-detector-specific-review-record\"><span class=\"ez-toc-section\" id=\"Build_a_detector-specific_review_record\"><\/span>Build a detector-specific review record<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li><strong>Identify the assessment.<\/strong> Record equipment, revision, tested port and applicable method. Verify that the requested evidence concerns this actual assembly rather than a different component or configuration.<\/li>\n<li><strong>Map each result.<\/strong> Record frequency, detector, level, units and associated limit. Verify that the correct line is selected before calculating any margin or copying a pass label.<\/li>\n<li><strong>Check the measurement conditions.<\/strong> Record bandwidth, timing, operating cycle and correction configuration. Verify that the relevant event was observed using the actual instrument&#39;s documented method.<\/li>\n<li><strong>Separate preliminary and final evidence.<\/strong> Record pre-scan findings and subsequent detector measurements distinctly. Verify any permitted substitution from its applicable basis; do not fabricate missing results.<\/li>\n<li><strong>Apply the declared decision rule.<\/strong> Record uncertainty handling, exceptions and the scope of the conclusion. Accept the report only when the required comparisons are supported, leaving unrelated system or market claims outside that result.<\/li>\n<\/ol>\n<figure class=\"article-figure product\" data-asset=\"H11-product\"><a class=\"product-image-link\" href=\"https:\/\/www.wehopower.com\/vi\/product\/ndr-dinrail-120w-ac-to-dc-single-output-switching-power-supply\/\" aria-label=\"NDR-120-24 details\"><img loading=\"lazy\" src=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/c1d1da3932e864b9-ndr-120-24-product-reference.webp\" alt=\"NDR-120-24 product reference preserving original housing, model marking and visible connection details for comparison.\" width=\"800\" height=\"800\" decoding=\"async\" title=\"\"><\/a><figcaption>WEHO NDR-120-24 product identification reference, retaining the source image&#8217;s visible identity. The photograph does not establish EMI emissions or compliance with any limit. <a href=\"https:\/\/www.wehopower.com\/wp-content\/uploads\/2026\/11\/e03f11f17a629a7f-ndr-120-24-product-original.jpg\" target=\"_blank\" rel=\"noopener\">View original-resolution image<\/a><\/figcaption><\/figure>\n<h2 id=\"prepare-an-ndr-120-24-emc-evidence-enquiry\"><span class=\"ez-toc-section\" id=\"Prepare_an_NDR-120-24_EMC_evidence_enquiry\"><\/span>Prepare an NDR-120-24 EMC evidence enquiry<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Send WEHO the <a href=\"https:\/\/www.wehopower.com\/vi\/product\/ndr-dinrail-120w-ac-to-dc-single-output-switching-power-supply\/\">NDR-120-24 candidate reference<\/a>, host configuration, load, intended market and the exact documentation question. Include the detector-specific report rows if interpreting an existing test. Request applicable model evidence without presenting that evidence as automatic approval of the complete equipment.<\/p>\n<p>Before the next review, label the detector, attach its correct comparison line and retain the operating conditions. Those actions make the reported margin traceable while keeping precompliance observations, formal laboratory conclusions and product photographs in their proper roles.<\/p>\n<h2 id=\"engineering-faq\"><span class=\"ez-toc-section\" id=\"Engineering_FAQ\"><\/span>Engineering FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"can-an-average-result-be-lower-yet-fail-its-comparison\"><span class=\"ez-toc-section\" id=\"Can_an_average_result_be_lower_yet_fail_its_comparison\"><\/span>Can an average result be lower yet fail its comparison?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes. An average result can exceed its own lower applicable limit while a higher quasi-peak result remains below another limit. Compare each detector&#39;s result to its associated line rather than ranking the levels alone.<\/p>\n<h3 id=\"is-an-average-of-displayed-db-values-an-emi-average-result\"><span class=\"ez-toc-section\" id=\"Is_an_average_of_displayed_dB_values_an_EMI_average_result\"><\/span>Is an average of displayed dB values an EMI average result?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. The specified detector operation and an arithmetic average of decibel readings are different procedures. Identify the actual instrument mode, weighting and method before treating a software average as the required EMI quantity.<\/p>\n<h3 id=\"does-a-peak-pre-scan-crossing-automatically-prove-quasi-peak-failure\"><span class=\"ez-toc-section\" id=\"Does_a_peak_pre-scan_crossing_automatically_prove_quasi-peak_failure\"><\/span>Does a peak pre-scan crossing automatically prove quasi-peak failure?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. It identifies a condition requiring interpretation or further measurement within the applicable method. The quasi-peak and average outcomes must be supported by their measurements or an explicitly valid substitution, not assumed from the peak label alone.<\/p>\n<h3 id=\"are-the-60-and-50-db-v-example-lines-legal-limits-for-this-supply\"><span class=\"ez-toc-section\" id=\"Are_the_60_and_50_dB%C2%B5V_example_lines_legal_limits_for_this_supply\"><\/span>Are the 60 and 50 dB\u00b5V example lines legal limits for this supply?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. They are invented worksheet inputs used to explain detector-specific comparisons. The actual product, installation, port, market and applicable assessment determine which documented requirements and decision rule must be used.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Map each EMI detector result to its own limit before judging a report. Send WEHO the NDR-120-24 equipment scope, operating state and test evidence.<\/p>","protected":false},"author":2,"featured_media":22647,"parent":0,"menu_order":39,"comment_status":"","ping_status":"","template":"","format":"standard","meta":{"_acf_changed":false,"_joinchat":[],"footnotes":""},"news_category":[284],"class_list":["post-23269","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-product-articles","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news\/23269","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/comments?post=23269"}],"version-history":[{"count":0,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news\/23269\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/media\/22647"}],"wp:attachment":[{"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/media?parent=23269"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.wehopower.com\/vi\/wp-json\/wp\/v2\/news_category?post=23269"}],"curies":[{"name":"wp c\u1ee7a t\u00f4i","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}