HDR-30 Series 30W Ultra Slim Step Shape DIN Rail Power Supply (HDR-30-12 / HDR-30-24)

WEHO’s HDR-30 is a compact, single-output DIN-rail power-supply family for low-voltage control, sensing and communications equipment. Separate 5V, 12V, 24V and 48V versions help match the supply to the equipment input, while the 35 × 90 × 54.5mm body supports space-conscious panel layouts. Select the exact voltage/current version and check the load and cabinet conditions before ordering.

إذا كان لديك أي أسئلة، فلا تتردد في الاتصال بنا على بريد إلكتروني: [email protected]

 

نموذج تقرير التنمية البشرية-30-5 تقرير التنمية البشرية-30-12 تقرير التنمية البشرية-30-24 تقرير التنمية البشرية-30-48
DC output voltage, current 5 فولت 0 ~ 3 أمبير 12 فولت 0 ~ 2 أمبير 24 فولت 0 ~ 1.5 أمبير 48 فولت 0 ~ 0.75 أمبير
الموجة والضوضاء 80mVp-p 120mVp-p 150mVp-p 240mVp-p
استقرار سلك المدخل ±1% ±1% ±1% ±1%
استقرار التحميل ±1% ±1% ±1% ±1%
كفاءة 80% 86% 87% 87%
Adjustable Range for DC Voltage ±10% ±10% ±10% ±10%
نطاق جهد الإدخال 85 ~ 264VAC. 120 ~ 370VDC. 47 ~ 63 هرتز
تأثير الحالي Cold start current: 25A/115VAC; 45A/230VAC
حماية الزائد 105%~150% cut off the output, automatic recovery
حماية الجهد الزائد 115%~140% rated output power. Protection type: Hiccups mode, recovers automatically after fault condition is removed
الإعداد، الارتفاع، الانتظار 1500ms, 80ms/230VAC; 1500ms, 80ms/115VAC (at full load)
تحمل الجهد I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute
مقاومة العزلة I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC / 25℃ / 70%RH
درجة حرارة العمل -20℃~+70℃
البعد 35×90×54.5mm
وزن 0.12 كجم

Why choose the HDR-30 DIN-rail power supply?

Compact panel integration

The documented 35 × 90 × 54.5mm dimensions provide a concrete starting point for allocating DIN-rail space. Check the complete mechanical drawing and the space required by wiring and nearby equipment.

Four distinct DC voltage choices

HDR-30-5, HDR-30-12, HDR-30-24 and HDR-30-48 are separate single-output versions. Choose the version that matches the connected electronics rather than treating the four voltages as simultaneous outputs.

Broad documented input ranges

The specified input ranges are 85–264VAC and 120–370VDC, with an AC frequency range of 47–63Hz. Confirm the actual installation supply and the requirements of the selected revision.

Defined overload recovery

The specified overload range is 105%–150%, with output cut-off and automatic recovery. Coordinate the load and fault response so an overloaded circuit is not treated as normal continuous operation.

ميزة 30 واط DIN السكك الحديدية الصناعية مصدر الطاقة الناتج واحد

Model-specific output selection

The output table lists 5V 0–3A, 12V 0–2A, 24V 0–1.5A and 48V 0–0.75A for the respective models. Use the exact variant's voltage and current data for load selection; the family name is not a uniform continuous-power rating for every output option.

Documented regulation and adjustment

Line regulation and load regulation are each listed as ±1% for all four models. The DC voltage adjustment range is ±10%; confirm the connected equipment's allowable input before adjustment.

Variant-specific ripple and efficiency

The respective ripple/noise values are 80, 120, 150 and 240mVp-p; the respective efficiency values are 80%, 86%, 87% and 87%. Compare the exact model's figures with the application's noise and power-budget requirements.

Published electrical and mechanical interfaces

The terminal drawing identifies pin 1 as +V, pin 2 as −V, pin 3 as AC/L and pin 4 as AC/N. Admissible DIN rails are TS35/7.5 or TS35/15. Follow the mechanical drawing and the installation's electrical-safety requirements.

HDR-30 size

Typical service conditions

Cabinet layout and rail fit

Plan around the 35 × 90 × 54.5mm body and the specified TS35/7.5 or TS35/15 rail. Allow for terminal access, wire routing and the surrounding equipment; the dimensional drawing is not a universal clearance requirement.

Input supply and output polarity

Check the 85–264VAC or 120–370VDC input range against the actual source. The terminal drawing labels AC/L and AC/N separately from +V and −V. Confirm DC-input wiring for the selected unit rather than assuming that AC terminal labels alone define every DC installation.

Temperature and continuous-load planning

The stated working-temperature range is −20°C to +70°C. Evaluate the selected voltage/current version in the real enclosure and airflow conditions; this temperature range alone does not establish full-output operation at every ambient temperature.

Noise, start-up and fault coordination

Check the selected model's ripple/noise against the electronics being powered. The timing row lists 1500ms and 80ms at 230VAC and again at 115VAC, with a full-load condition. Coordinate downstream start-up and fault protection with the actual equipment.

Application guidance

The following are potential integration roles, not customer-installation claims. Match the exact DC voltage, steady-state current, start-up demand and environmental requirements of the equipment before selection.

Access-control electronics

Supply compatible reader, controller or interface electronics inside a protected access-control panel. Check the exact electronics input; door strikes, motors and other pulsed loads require their own load and protection assessment.

Process sensing and monitoring

Provide local DC power to compatible sensor interfaces, monitoring modules or compact indication electronics. Confirm the required supply voltage and current and compare the model's ripple/noise with the measurement-system requirements.

Building-automation control panels

Support compatible zone-controller or building-management interface electronics in a protected panel. Check panel temperature, available rail space and the connected devices' input limits; the supply alone does not establish outdoor or system-level approval.

Industrial communications interfaces

Power compatible gateways, serial-interface modules or local communications electronics with a matching DC input. Verify the complete load budget and start-up demand; selecting HDR-30 does not add PoE, backup or UPS functions.

HDR-30 technical FAQs

Which DC output versions are listed for HDR-30?

The listed models are HDR-30-5, HDR-30-12, HDR-30-24 and HDR-30-48, providing nominal 5V, 12V, 24V and 48V outputs respectively. Each is a single-output version.

What output-current ranges are specified for the four versions?

The table specifies 0–3A at 5V, 0–2A at 12V, 0–1.5A at 24V and 0–0.75A at 48V. Keep each current range with its own model; do not substitute a common current or power limit across the four versions.

What input-voltage and frequency ranges are specified?

The input-voltage ranges are 85–264VAC and 120–370VDC. The AC frequency range is 47–63Hz. Confirm the selected unit and the installation requirements before connection.

What line-regulation and load-regulation figures are listed?

Line regulation and load regulation are each listed as ±1% for every HDR-30 output version.

What DC voltage adjustment range is listed?

The table lists a ±10% DC voltage adjustment range for each version. Check the load's allowable input range before changing the output setting.

What ripple/noise values are listed?

The values are 80mVp-p for HDR-30-5, 120mVp-p for HDR-30-12, 150mVp-p for HDR-30-24 and 240mVp-p for HDR-30-48. Confirm any application-specific measurement conditions separately.

What efficiency values are listed?

The listed efficiency values are 80% for HDR-30-5, 86% for HDR-30-12, and 87% for both HDR-30-24 and HDR-30-48. Use the figure for the selected voltage version.

What cold-start inrush-current figures are specified?

Cold-start current is listed as 25A at 115VAC and 45A at 230VAC. Keep the two values tied to their stated input voltages when assessing upstream protection.

How is overload recovery specified?

Overload protection is listed at 105%–150%, with the output cut off and automatic recovery. Verify the response with the actual load and do not use the protection range as a normal continuous operating rating.

What timing information is provided for HDR-30?

The timing row prints 1500ms and 80ms at 230VAC, and 1500ms and 80ms at 115VAC, with a full-load condition. It does not print a separate third hold-up-time value.

What temperature range and body dimensions are stated?

The working-temperature range is −20°C to +70°C. Body dimensions are 35 × 90 × 54.5mm and weight is 0.12kg. Confirm thermal performance for the actual load and enclosure rather than assuming full output at every temperature.

Which terminal assignments and DIN rails are shown?

The drawing identifies pin 1 as +V, pin 2 as −V, pin 3 as AC/L and pin 4 as AC/N. The admissible DIN rails are TS35/7.5 and TS35/15. Use the complete drawing and installation instructions for final integration.