15.000 W PID-Akkuladegerät mit einstellbarer Spannung für Blei-Säure- und Lithium-Akkus mit PFC

Ultimate Charging Hub for 13.8V – 58.4V Systems: The pinnacle of power delivery for ESS and large-scale AGV fleets. Engineered to hit 13.8V, 14.6V, 27.6V, 29.2V, 55.2V, and 58.4V with uncompromising precision across multiple rated voltage models.

Programmable Massive Power: Unleashes up to 18kW of energy with full Modbus control. Features dedicated dry-contact alarm signals for “Power Good” status monitoring in critical infrastructure.

Grid-Level Safety Protocol: Advanced protection logic allows users to set specific overvoltage shutdown points. The system manages temperature-controlled recovery and short-circuit lockouts automatically.

High-Density Engineering: Reaches up to 93% efficiency with a professional 455x345x251mm design. Ideal for high-vibration and high-temperature industrial settings.

Modell HPS-15000-30 HPS-15000-36 HPS-15000-48 HPS-15000-60 HPS-15000-110 HPS-15000-220
Gleichspannung 30V 36V 48V 60V 110V 220V
Nennstrom 400A 333,3A 250A 200A 109.1A 54.5A
Aktueller Bereich 0-400A 0-333,3A 0-250A 0-200A 0-109.1A 0-54.5A
Nennleistung 15000W
Welligkeit 500 mV 500 mV 600 mV 600 mV 1000 mV 1500 mV
Optimaler Konstantstrombereich 15-30V 18-36V 24-48V 30-60V 55-110V 110–220 V
Genauigkeit der Nennspannung    ± 1,0%
Linienregulierung    ± 1,0%
Lastregulierung    ± 1,0%
Start- und Anstiegszeit    1500mS,700mS/230VAC(Fully loaded)
Spannungsbereich    95–190 VAC (Ausgangsstrom 50%), 195–265 VAC (Ausgangsstrom 100%)
Frequenzbereich    45Hz-65Hz
Leistungsfaktor    PF≥0.99/230VAC(Fully loaded)
Effizienz (MAX) 91% 91.5% 92% 92% 92.5% 93%
ACCurent    <110A
Leckstrom    <3,0 mA/240 VAC
Kurzschluss Enter the constant curent and the voltage is less than 10%of therated voltage,turn off and lockthe output after 1 second,and resume after restart
Überstrom The user can set a delay of 5 seconds after the current value is turned off,and the output can be restored after restart.
Überdruck The user can set the overvoltage value to turn off the output voltage,and resume after restart.
Übertemperatur Turn off the output and automatically recover or restart after the temperature drops
Einstellung der Ausgangsspannung 0-33V 0-39,6 V 0-52,8 V 0-66V 0-121V 0-242V
Einstellung des Ausgangskonstantenstroms 0-400A 0-333,3A 0-250A 0-200A 0-109.1A 0-54.5A
485Communications    MODBUS-Kommunikationsprotokoll
solated auxiliary power supply    12V0.5A(Need customization)
Ausgangsfernschalter Standardmäßiges Einschalten, hohes Ausschalten (5V-12V) (Anpassung erforderlich)
Alarmsignaloutput Power Good Signal (Dry Contact≤36V,0.1A)  (Need customization)
Betriebstemperatur    -20-+60℃
Betriebsfeuchtigkeit -20-90%RHnon-condensing
Storage temperatureandhumidity -40-+85℃,10-95%RH non-condensation
Vibrationsfestigkeit i0-500Hz,2G 10mins/T,X、Y、Zaxis 60 minutes each
insulation resistance Eingang zu Ausgang: 100 Mhms/500 VDC/25 °C/70%RH
Druckfestigkeit    /P-O/P:2KVAC IP-FG:2KVAC O/P-FG:0.5KVAC
size    455×345×251mm
net weight    22 kg