By WEHO
An inductive sensor's axial sensing distance does not directly specify where a laterally moving target edge will switch. Map the actual approach path at its working gap, with target geometry and direction retained. Use that path record to release a machine position, then verify the receiving signal chain separately.
- Separate axial gap from lateral position.
- Define a physical travel datum.
- Test both required travel directions.

Define the position that the machine needs to detect
A machine builder may know that a metal target passes within a nominal sensing distance yet still obtain a switching point in the wrong place. The target enters a three-dimensional sensing region along a particular path. Its axial gap and lateral coordinate are different quantities, and both can affect the operating point.
Der LJA18 inductive-sensor family reference identifies the cylindrical sensor family shown here. Select the complete suffix and mounting type from applicable documentation. The photograph does not distinguish every output logic or prove a switching envelope for the proposed target.
The purchasing decision is whether a documented sensor and mechanical arrangement can identify the required position across its allowed gap and travel variation. A path map, tied to the machine datum, provides a more useful acceptance output than a single nominal distance copied into a drawing.
Read axial distance and the operating-point path separately
OMRON's proximity-sensor terminology distinguishes approach perpendicular to the sensing face from movement parallel to it. For lateral motion, the operating point depends on the transit position relative to the reference surface. An axial rating is therefore not a lateral trigger coordinate.
Choose a coordinate system before collecting data. For example, define z as the target-to-sensing-face gap and x as edge travel along the machine axis, with x = 0 at a named mechanical datum. State the target orientation and which edge establishes x. A photograph without these definitions cannot recreate the measurement reliably.
The target's material, dimensions and surrounding metal remain part of the condition. OMRON's proximity-sensor selection overview identifies target and installation factors affecting sensing distance. Use those factors to define the test coverage; do not transfer another manufacturer's curve or a standard-target result to LJA18.
An operating-point path also differs from repeatability. Repeating one approach at one fixed gap assesses scatter there. Changing the gap changes the condition and may move the mean trigger position. Keep those effects separate when deciding whether mechanical tolerance or sensor variation dominates the acceptance problem.
Work a hypothetical lateral position record
Assume a fictional linear machine has a fixed sensor and one specified steel target. Define x = 0 at a fixture datum. The target moves in the positive x direction for the ON approach. At gaps z of 1, 2 and 3 mm, assume recorded ON positions of x = 8.0, 9.2 and 11.0 mm respectively.
These chosen numbers represent three hypothetical conditions, not LJA18 specifications or measured switching points. Across the 1–3 mm gap interval, the ON position changes by 11.0 − 8.0 = 3.0 mm. That condition-induced shift cannot be described as the repeatability of a single fixed setup.
Assume the project's acceptable ON window is x = 8.5 to 10.0 mm for this fictional machine. The 2 mm gap condition is inside that window, while the 1 mm and 3 mm conditions are outside it. The result would require review of the allowed gap range or sensing arrangement; it does not supply a universal preferred gap.
Swipe to view the complete diagram, or open full size.
Swipe table horizontally when needed.
| Assumed axial gap z | Assumed ON position x | Project ON window | Example decision |
|---|---|---|---|
| 1.0 mm | 8.0 mm | 8.5–10.0 mm | Outside this requirement |
| 2.0 mm | 9.2 mm | 8.5–10.0 mm | Within this condition |
| 3.0 mm | 11.0 mm | 8.5–10.0 mm | Outside this requirement |
Do not linearly interpolate an untested sensor curve merely because the three values form a convenient trend. Collect the conditions required by the mechanical tolerance and acceptance plan. Include uncertainty and repeated observations where their magnitude could change the decision at a boundary.

Map the actual approach with a repeatable procedure
- Identify the complete sensor suffix, mounting arrangement and intended target. Record material, dimensions, orientation and nearby metal. Verify the proposed installation against the applicable sensor instructions before using it as a test baseline.
- Define the face reference, axial gap and lateral datum. Record the edge or feature used to measure position. Verify that another operator can reproduce the same coordinates without using a bracket slot or photograph as an undefined zero.
- Select the allowed gaps and travel directions from the machine requirement. Record the required ON and OFF windows separately. Verify that all conditions come from the actual tolerance envelope rather than a convenient nominal position alone.
- Move the target through each permitted path and record sensor transitions with position. Retain direction, speed and acquisition method. Verify that the recorded event represents the sensor's switching state and identify any additional position shift from electrical delay.
- Repeat the relevant conditions to distinguish fixed-condition scatter from changes caused by gap, direction or target orientation. Preserve the individual results. Verify the project window using the agreed uncertainty and acceptance approach.
- Check the complete receiving input at the required production speed. Record sensor output and controller recognition separately. Verify that acceptable mechanical switching positions are not lost through filtering, sampling or an incompatible electrical interface.
Use the equipment's approved positioning and commissioning procedures. A process sensor is not automatically a safety device, and this path test does not establish a protective function. Keep access, movement permission and independent safeguards under the machine design.
Separate geometric switching from time-related displacement
A target moving at speed v travels an additional distance v × Δt during a downstream delay Δt. For an explicitly hypothetical example, v = 0.40 m/s and Δt = 5 ms give 0.40 × 0.005 = 0.002 m, or 2.0 mm. That displacement belongs to the specified timing boundary.
The 2 mm calculation does not identify a LJA18 response time or PLC delay. It explains why a machine's recognized position can differ from the sensor's physical operating point. Record the actual signal chain and speed before attributing the entire position difference to the magnetic sensing region.
A reverse travel can add another distinction. The sensor's OFF point may differ from its ON point because of switching hysteresis, and the target may enter from the opposite edge. Keep the edge identity and direction explicit; subtracting two unsigned positions can conceal which physical features were compared.
A replacement bracket can change more than nominal gap. It may rotate the sensor face or alter the target's lateral track. Compare the actual coordinate relationship after maintenance. A repeated cable signal at one stationary target position does not establish the complete moving-path acceptance.
If the machine cannot maintain the assumed gap, identify the required detection window before choosing a remedy. Mechanical control of the path, a different sensing arrangement or another documented sensor candidate may be appropriate. The evidence should guide that decision rather than treating a longer nominal sensing distance as an automatic solution.
Send the path drawing with the sensor enquiry
Use the LJA18 family configuration documentation entry to identify candidate suffixes, then send WEHO the application record with the target drawing, mounting metal, axial-gap range and lateral switching window. Include required travel directions, speed and the receiving input. Ask which exact variant and supporting data apply to that path.
Keep the family photograph as an identity reference, while the ordered suffix and tested arrangement control the release. A coordinate drawing with a few clearly identified conditions gives the supplier a more answerable question than requesting a sensor with a nominal distance that happens to exceed the gap.
Engineering FAQ
Can an axial sensing distance specify a lateral ON position?
Not by itself. The lateral operating point depends on the target path and gap, along with the actual target and installation. Obtain applicable path information or qualify the required arrangement.
Is a gap-dependent position shift a repeatability error?
It is a change of condition. Fixed-condition repeatability and the change caused by a different gap should be evaluated and recorded separately.
Can increasing nominal sensing distance solve the position problem?
It does not automatically solve it. The required lateral window and allowed mechanical envelope determine the decision. Compare the actual candidate's documented or qualified path behavior.
Why record production speed after a static path test?
Signal and receiving delays can translate into additional travel at speed. A static geometric result does not establish the position where the complete control system recognizes the event.