S-35W series normal single switching power supply

WEHO S-35 is a compact 35W-designated single-output family with 5V, 12V, 15V and 24V options for compatible machine-interface and instrument electronics. It provides manual AC range selection at 90~132VAC/180~264VAC, with 254~370VDC also specified. The 129×98×38mm outline and 0.4kg mass support installation planning. Evaluate the selected output’s current range, ripple and startup demand for the actual equipment.

Εάν έχετε οποιεσδήποτε ερωτήσεις, μη διστάσετε να επικοινωνήσετε μαζί μας στο email: [email protected]

Προσδιορισμός S-35-5 S-35-12 S-35-15 S-35-24
DC τάση εξόδου, ρεύμα 5V 0~7A 12V 0~3A 15V 0~2.4A 24V 0~1.5A
Κύμα και θόρυβος 70mVp-p 100mVp-p 100mVp-p 100mVp-p
Σταθερότητα καλωδίου εισόδου ±0,5% ±0,5% ±0,5% ±0,5%
Σταθερότητα φορτίου ±1% ±0,5% ±0,5% ±0,5%
Αποδοτικότητα 70% 76% 78% 78%
Ρυθμιζόμενο εύρος για τάση DC ±10% ±10% ±10% ±10%
Εύρος τάσης εισόδου 90~132VAC/180~264VAC by switch 254~370VDC 47~63Hz
Ρεύμα κρούσης Cold start current 18A/115VAC 36A/230VAC
Προστασία υπερφόρτωσης 105%~150% διακόπτει την έξοδο, αυτόματη ανάκτηση
Προστασία από υπέρταση 115% ~ 135% shut down O/P voltage, re-power on to recover
Ρύθμιση, άνοδος, χρόνος αναμονής 200ms,100ms,30ms/230VAC at full load
Αντοχή στην τάση I/P-O/P:1,5kV I/P-FG:1,5kV O/P-FG:0,5kV 1 λεπτό
Αντοχή στην απομόνωση I/P-O/P I/P-FG O/P-FG:500VDC/100MΩ
Θερμοκρασία εργασίας -10℃~+50℃
Διάσταση 129×98×38mm
Βάρος 0.4kg
Συσκευασία 43×32.5×24CM/45PCS/18kg

Why Choose the S-35?

Select the exact electronic supply requirement

The options range from S-35-5 at 5V 0~7A to S-35-24 at 24V 0~1.5A, with separate 12V and 15V variants. Match the board voltage first, then assess startup and continuous demand. The four columns are not simultaneous outputs or a selectable multi-voltage unit.

Include the stated inrush pair in upstream design

The S-35 cold-start row gives 18A/115VAC and 36A/230VAC. Assess upstream switching at the stated input-voltage conditions. Verify switch, protective-device and equipment-startup behavior for the real installation.

Check sensitive 5V loads against their own figures

S-35-5 lists 70mVp-p ripple, ±0.5% line stability and ±1% load stability. The other outputs list 100mVp-p ripple and ±0.5% load stability. A counter or communication board needs the figures for its ordered suffix, not a family-wide best case.

Evaluate service access around the 129mm outline

Use the 129×98×38mm outline to plan mounting, terminal access and service space. Establish the required barriers and thermal clearance for the complete equipment. A related family name or similar photograph does not establish drop-in replacement compatibility.

S-35 Features

Model-bound output current ranges

S-35-5 lists 5V 0~7A; S-35-12 lists 12V 0~3A; S-35-15 lists 15V 0~2.4A; S-35-24 lists 24V 0~1.5A. The 35W family designation and printed current ranges do not define the complete continuous operating envelope.

Voltage adjustment is not current control

All four variants list ±10% DC-voltage adjustment and ±0.5% line stability. Set the voltage only within the connected board’s limits and the accepted model duty. The entry does not establish constant-current operation, dimming or battery charging.

Manual input selection with conditioned timing

The AC bands are 90~132VAC/180~264VAC by switch, with 254~370VDC and 47~63Hz also listed. Setup, rise and hold-up are 200ms, 100ms and 30ms at 230VAC and full load. Neither entry removes the need to verify the delivered unit’s setting and connection instructions.

Different recovery paths for different faults

The overload range is 105%~150%, cutting off output with automatic recovery. Overvoltage is 115%~135%, shutting down output and requiring re-powering. These protective responses do not approve sustained overload or replace a complete equipment protection design.

Typical Service Conditions

Keep textile dust outside an edge-guide display bay

An edge-guide display bay may evaluate a qualified S-35 output for compatible indication and interface electronics. Keep fibres away from the electrical compartment and assess its actual temperature. Web-guiding actuators, drives and alignment accuracy remain separate system functions.

Control wiring around a resistance-weld monitoring console

A weld-monitoring console needs segregation from high-current weld conductors and verification of noise at its electronic loads. S-35 would be assessed only for accepted local monitor electronics. It is not the weld source and does not establish welding performance or immunity of the finished monitor.

Protect a vacuum-leak instrument rack from process exposure

A vacuum-leak instrument rack should keep the supply in a dry, protected electrical section. Validate thermal conditions and the exact output’s demand. Vacuum pumps, gauges requiring special excitation and calibrated leak-rate measurement need separately accepted equipment.

Assess startup in a sachet-seal controller compartment

A sachet-seal controller may change its electronic demand during startup and diagnostics. Test the selected S-35 output with the real control boards and safe reset policy. Seal heaters, feed motors and cutting actuators are not covered by this local electronic-load concept.

Potential S-35 Applications

Industrial punch-counting panel

A punch-counting panel may assess a selected output for compatible counter, display and communication boards. Confirm actual duty and signal-interface noise. Press actuation, clutch power and operator protection must remain independently supplied and qualified.

Bearing-temperature acquisition station

Evaluate an exact S-35 model for compatible local data-acquisition electronics after checking voltage and ripple tolerance. Temperature-sensor excitation, channel isolation, calibration and any machine trip are separate requirements. The supply alone does not establish measurement accuracy.

Carton dimension indicator

A carton dimension indicator may consider an accepted output for compatible display and interface electronics in a protected cabinet. Confirm the actual boards and interruption response. Optical emitters, conveyor motors and dimensional measurement performance require independent validation.

Air-filter differential-pressure logger

Consider a qualified S-35 version for compatible logger and communication electronics. Keep the electrical compartment away from moisture and contamination, and verify the selected voltage. Pressure sensing, channel isolation and a protective filter alarm are not established by the supply specification.

S-35 Technical FAQs

Which exact output models and current ranges are listed?

S-35-5 lists 5V 0~7A; S-35-12 lists 12V 0~3A; S-35-15 lists 15V 0~2.4A; S-35-24 lists 24V 0~1.5A. They are alternative single-output models, not four simultaneous rails.

Does the 35W designation approve every continuous operating point?

The family designation and printed current ranges are separate entries. Do not calculate a replacement continuous wattage from their endpoints or assume maximum output at every input and temperature. Confirm the ordered suffix’s continuous and startup duty; the printed zero lower bounds do not independently establish minimum-load or no-load acceptance.

Is the AC input automatically selected?

The sheet states 90~132VAC/180~264VAC by switch, plus 254~370VDC and 47~63Hz. Select the correct AC band before energizing; this is not automatic range selection. Confirm separate DC-input connection instructions before DC use.

What does the voltage-adjustment entry establish?

Each model lists ±10% DC-voltage adjustment. It does not establish regulated-current output, dimming, arbitrary programmable operation or battery charging. Confirm the adjustment procedure, connected load voltage limits and accepted operating envelope before using a changed setting.

What ripple and line/load stability apply to each output?

S-35-5: 70mVp-p; S-35-12: 100mVp-p; S-35-15: 100mVp-p; S-35-24: 100mVp-p. All four list ±0.5% line stability; the 5V version lists ±1% load stability and the other outputs ±0.5%. No ripple measurement bandwidth or wiring method is specified by these entries.

Which efficiencies and cold-start values belong to this model?

Efficiencies in S-35-5, S-35-12, S-35-15, S-35-24 order are 70%, 76%, 78%, 78%. Cold-start current is 18A/115VAC and 36A/230VAC. Efficiency depends on the selected output; each cold-start value applies to its stated input voltage and is not a continuous input-current rating.

How does overload protection recover?

The overload entry is 105%~150%, cutting off the output with automatic recovery. This is not a continuous overload allowance or a replacement for cable and branch protection. Evaluate the connected electronics’ behavior during repeated power loss and recovery as part of the equipment design.

Does overvoltage shutdown recover automatically?

The overvoltage entry is 115%~135%, shutting down the output voltage and requiring re-powering to recover. Keep this separate from automatic overload recovery. Safe restart and downstream protection need their own equipment-level verification.

Which setup, rise and hold-up values and conditions are specified?

Setup, rise and hold-up are 200ms, 100ms and 30ms at 230VAC and full load. The stated input and full-load conditions apply to this timing entry. Full-load timing does not establish full load throughout the temperature range or identical response at every input and load.

What working temperature, dimensions and mass are listed?

The values are -10°C~+50°C, 129×98×38mm and 0.4kg. Check actual mounting, terminal access, service clearance and local thermal conditions. These entries do not provide an ingress rating, humidity specification or complete full-load derating curve.

What withstand and isolation-resistance entries are printed?

The withstand row lists I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute, without an AC/DC qualifier. Isolation resistance is listed as 500VDC/100MΩ for the named input/output/frame-ground pairs. These component test entries do not establish certification scope or finished-equipment approval.

What terminal order is shown, and can it be transferred between models?

The S-35 legend labels pins 1 and 2 as AC input, pin 3 as GND, pin 4 as DC output-V and pin 5 as DC output+V. Confirm the exact delivered unit, terminal markings and connection instructions before wiring, including a proposed DC-input application. Similar enclosures do not authorize transferring another model’s wiring.