Check a transformer current monitor's droop and pulse limits before interpreting a falling pulse plateau as load-current decay. These monitors respond to changing current and cannot measure steady DC. A fast rise-time rating does not establish accurate reproduction of a long flat pulse.
- Match the full pulse duration to the monitor's droop data.
- Check current-time and DC-bias limits separately.
- Preserve termination and repetition conditions.
- Compare an independent current method before assigning the decline to the source.

Define the current event and the monitor technology
An OEM can observe a current pulse rise correctly and then slope downward during the intended plateau. That trace may represent a changing load, source response or the measurement chain. Identifying the current sensor technology is therefore part of diagnosing the waveform, not an administrative detail.
For a setup involving the WEHO MDR-60-12 source reference, retain the source model and operating condition alongside the exact monitor identity. The calculations below describe a hypothetical current monitor and pulse. They are not a claim about the supply's current, protection response or measured performance.
A transformer current monitor differs from a DC-capable Hall or fluxgate probe. The relevant low-frequency limitations, offset behavior and saturation mechanisms are not interchangeable. Record the actual sensor, cable, termination and scaling rather than labeling every device simply as a current probe.
Separate leading-edge bandwidth from plateau fidelity
A monitor may reproduce a rapid edge while gradually losing the level associated with a constant current. Its low-frequency response determines this plateau behavior. A bandwidth specification focused on the high-frequency end does not close the low-frequency error budget.
Pearson's droop note explains that a transformer monitor output decays toward zero during a constant-current plateau and that the quoted droop is a first-order approximation to that exponential response. Use the actual model's conditions rather than treating a convenient percentage as universal.
Current-time capability introduces another boundary. The integrated current during a pulse and any DC component can affect core flux. The Pearson application notes discuss model-specific pulse limits and bias effects. A monitor that is satisfactory for a short pulse may not remain satisfactory when its plateau or repetition changes.
The falling trace can contain both real circuit behavior and monitor error. Correcting it requires an applicable response model and adequate evidence; simply drawing a horizontal line through the end points is not a measurement correction. Keep the original trace before any processing.
Calculate a hypothetical small-droop example
Assume a hypothetical monitor specifies a droop rate of 0.20% per millisecond under the relevant conditions. The intended current pulse has an 8 ms plateau. The first-order estimated decline is 0.20 × 8 = 1.6% of the plateau indication.
If the actual current were a constant 20 A, the indicated end value would be approximately 20 × (1 − 0.016) = 19.68 A. A 0.32 A apparent decline could therefore arise from the assumed monitor response without any real current change. No particular monitor or WEHO product is represented by these inputs.
The pulse current-time product is 20 A × 0.008 s = 0.160 A·s. Compare that value, along with peak current, repetition and bias, against the actual monitor's applicable limits. The product alone cannot approve the sensor because its starting flux and reset conditions can matter.
Swipe to view the complete diagram, or open full size.
Do not extend the simple percentage multiplication to arbitrarily long pulses. The note's underlying response is exponential, and the quoted linear droop approximation has an applicable range. For larger errors, use the supplier's transfer behavior or a different measurement method appropriate to the required plateau accuracy.
An acceptance budget should allow for other contributions: sensitivity accuracy, termination, instrument range, offset in downstream electronics and noise. Avoid using the droop estimate as though it were the only uncertainty or a guaranteed correction at every current level.
Match the monitor to the complete pulse record
Ο Pearson selection guide treats pulse duration and droop separately from rise time and states that these monitors do not measure steady DC. That distinction supports a task-based selection record: peak, edge and plateau all need evidence.
Swipe table horizontally when needed.
| Event property | Monitor evidence | Question to close |
|---|---|---|
| Leading edge | Usable rise time and connection response | Is the edge shape adequately reproduced? |
| Plateau duration | Applicable droop behavior | Is level error small enough for the task? |
| Pulse area and bias | Current-time and DC-bias conditions | Is core saturation avoided? |
| Repetition and recovery | Reset and operating conditions | Does every event begin in a valid state? |
A pulse train can have a nonzero average even when current returns to zero between pulses. Keep duty cycle and the full sequence in the brief. Selecting a monitor from one isolated event can miss the operating state created by repeated pulses.
Output termination also matters. Follow the monitor manufacturer's cable and instrument input guidance, and preserve the calibration scaling associated with that arrangement. Changing a termination can alter sensitivity or waveform quality; it should not be treated as a harmless display adjustment.
Validate the indicated decline before diagnosing the supply
- Identify the sensor technology and exact model. Obtain the applicable droop, peak, current-time, bias and output-connection information.
- Record the full pulse sequence, including baseline and recovery between events. Save the actual duration and repetition instead of only a cropped plateau.
- Estimate the expected measurement-chain contribution within the method's valid range. Compare it with the size of the decline being investigated.
- Repeat using an independently suitable current method or a qualified reference pulse. Keep the same circuit conditions and document any changed burden or connection.
- Compare current with synchronized source and receiver voltage. Assign a circuit explanation only after measurement-chain effects are adequately resolved.

A shunt comparison can be useful, but its insertion changes the circuit and requires suitable power, bandwidth and electrical isolation arrangements. A DC clamp can provide a plateau comparison while having different edge limitations. Choose the reference method for the specific question and account for its own limitations.
Do not assume that increasing the scope's averaging removes droop. Averaging repeated copies can make a systematic slope look smoother without making it correct. Similarly, AC coupling or baseline adjustment elsewhere in the chain can add another low-frequency response that needs separate evaluation.
Retain observations that distinguish repeatability from validity. A stable 1.6% decline on every pulse may be reproducible, yet still describe the monitor rather than the current. Conversely, a decline that varies with pulse width may be consistent with monitor behavior but remains a hypothesis until checked against the model and reference evidence.
Record which conductor passes through the monitor opening. Including both outgoing and returning current paths can cancel the net linked current and answer a different question. Follow the monitor's application instructions and preserve the physical arrangement rather than inferring it from the plotted amplitude.
Keep the scope input range and monitor sensitivity in the same review. An unclipped monitor does not guarantee an unclipped receiving channel. Conversely, a channel with ample voltage range cannot prevent core saturation. The two limits act at different points in the chain and require separate evidence.
Submit the complete current-measurement context
For the WEHO MDR-60-12 pulse-test source, send the current and voltage records, load timing, monitor model, termination, scaling and relevant pulse limits. Explain whether the review concerns edge shape, plateau level or source recovery so the evidence can be assessed against the right question.
A useful conclusion identifies the observed decline and its remaining measurement contribution. If the monitor cannot meet the required plateau fidelity, change the method before rejecting the source. The resulting record should state which part of the event is trustworthy and which additional comparison closes the diagnosis.
Engineering FAQ
Can a transformer current monitor measure steady DC?
A transformer current monitor cannot measure steady DC. It can reproduce suitable changing currents and pulses within its model-specific limits. Use an appropriately DC-capable method when the steady level is the required quantity.
Does excellent rise time guarantee a flat pulse plateau?
Rise time describes a different part of the response from plateau droop. Check both the high-frequency edge behavior and low-frequency level error for the actual pulse duration.
Can I subtract the calculated droop from every measured pulse?
A correction needs an applicable model, conditions and uncertainty assessment. The simple duration-times-rate estimate is limited and may not represent saturation, low-current behavior or the whole chain. Preserve the raw trace and validate any correction.
Why does repetition matter if each pulse is unchanged?
Repetition changes the average current and recovery history. Those conditions can affect a transformer monitor's starting state and applicable limits. Evaluate the complete pulse train rather than one cropped event.