| Especificación | C-100 - 105 años | N º 100 - 12 | S-100-18 | N º 100 - 24 | S-100-36 | N º 100 - 48 |
| Tensión de salida CC, corriente | 5V 0 ~ 20A | 12V 0 ~ 8.5A | 18V 0 ~ 5.5A | 24V 0 ~ 4.5A | 36V 0 ~ 3A | 48V 0 ~ 2.1A |
| Ola y ruido | 75 mVp-P | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Estabilidad del cable de entrada | ±0,5% | ±0,3% | ± 0.2% | ± 0.2% | ± 0.2% | ± 0.2% |
| Estabilidad de carga | ±0,5% | ±0,3% | ± 0.2% | ± 0.2% | ± 0.2% | ± 0.2% |
| Eficiencia | 78% | 81% | 84% | 84% | 84% | 84% |
| Rango ajustable para voltaje CC | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
| Rango de voltaje de entrada | 90 ~ 132VAC/180 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz | |||||
| Corriente de impacto | Corriente de arranque en frío 30A/115VAC 60A/230VAC | |||||
| Protección contra sobrecarga | 105% ~ 150% cut off the output, automatic recovery | |||||
| Protección contra sobretensión | 115% ~ 135% shut down O/P voltage, re-power on to recover | |||||
| Configurar, levantarse, mantener el tiempo de actividad | 200ms, 50ms, 20ms/230VAC at full load | |||||
| Voltaje de soporte | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||||
| Resistencia de aislamiento | I/P-O/P, I/P-FG, O/P-FG: 500 VCC/100 MΩ | |||||
| Temperatura de trabajo | -10°C ~ +50°C | |||||
| Dimensión | 199 × 98 × 38mm | |||||
| Peso | 0.6kg | |||||
| Embalaje | 43 × 32.5 × 24CM/30PCS/18kg | |||||
Fuente de alimentación conmutada única normal serie S-100W
WEHO S-100 is a 100W-designated single-output family with six documented alternatives: 5V, 12V, 18V, 24V, 36V and 48V. Its 199×98×38mm outline gives equipment builders a defined form to assess for compatible supervisory and communication electronics. Input is 90~132VAC/180~264VAC by switch, with 254~370VDC also listed. The 18V option and output-dependent stability figures are important selection distinctions. Match one exact suffix to the electronic load, then verify startup, continuous duty, thermal conditions and terminal connections for the assembly.
Si tiene alguna pregunta, no dude en contactarnos en Correo electrónico: [email protected]
- Descripción
Why Choose the S-100?
Use the documented 18V alternative when the board requires it
S-100-18 lists 18V 0~5.5A alongside the 5V, 12V, 24V, 36V and 48V models. This gives an explicit 18V selection path for a compatible electronic assembly. It is not evidence of a 15V model or permission to adjust another version to an undocumented operating point.
Compare regulation by the exact output suffix
S-100-5 lists ±0.5% line and load stability, S-100-12 lists ±0.3% for each, and the 18V, 24V, 36V and 48V models list ±0.2% for each. These differences help screen voltage-sensitive boards. They do not justify assigning the best figure to the entire family.
Include the S-100 inrush pair in upstream assessment
Cold-start current is 30A/115VAC and 60A/230VAC. Use those input-qualified transients when reviewing switches and the equipment startup sequence. These are input-qualified cold-start transients, not continuous input-current ratings.
Keep seven-terminal access in the mechanical review
The 199×98×38mm outline and drawing with duplicated signed output terminals affect service access and conductor planning. Check the delivered markings and connection instructions. Two terminals carrying the same sign do not create extra independently regulated outputs or establish permitted strapping and current allocation.
S-100 Features
Six separately ordered voltage alternatives
S-100-5 lists 5V 0~20A; S-100-12 lists 12V 0~8.5A; S-100-18 lists 18V 0~5.5A; S-100-24 lists 24V 0~4.5A; S-100-36 lists 36V 0~3A; S-100-48 lists 48V 0~2.1A. The 100W designation and these model-specific current ranges do not define the complete continuous operating envelope.
Output-specific noise and efficiency
The 5V version lists 75mVp-p ripple and 78% efficiency. The 12V version lists 100mVp-p and 81%; the 18V, 24V, 36V and 48V versions each list 100mVp-p and 84%. Evaluate each version’s board-noise tolerance and thermal contribution using its own values.
Manual AC selection and three timing figures
The input entry is 90~132VAC/180~264VAC by switch, plus 254~370VDC and 47~63Hz. Setup, rise and hold-up are 200ms, 50ms and 20ms at 230VAC and full load. These conditions belong in the equipment startup review, not a universal-input or interruption-free promise.
Voltage trim with separate fault recovery
Each version lists ±10% DC-voltage adjustment. Overload at 105%~150% cuts off output with automatic recovery, while overvoltage at 115%~135% requires re-powering after shutdown. Voltage adjustment does not establish current regulation, dimming, battery charging or programmable operation.
Typical Service Conditions
Keep a tool-presetter readout stable through startup
A CNC tool-presetter readout station may evaluate an exact S-100 output for compatible readout and communication boards. Measure the actual boot demand and verify reset behavior after interruptions. Optical illumination, probe excitation, calibrated references and positioning axes need separate supplies and qualification.
Exclude dust from a hopper-level annunciator
A hopper-level annunciator mast needs a protected electronics compartment with verified thermal conditions and contamination control. A suitable S-100 version would supply only compatible local annunciator and interface boards. Level-sensor excitation, material gates and hazardous-dust suitability are independent requirements.
Segregate supply wiring at an RF shield-box bench
An RF shield-box test bench should segregate mains conductors from signal paths and verify noise at its local electronics. Consider S-100 only for compatible status and interface boards after load checks. Radio-frequency generation, measurement references and shielding performance are not provided by the power supply.
Assess heat around a hydraulic diagnostic desk
A hydraulic power-pack diagnostic desk needs separation from hot oil lines and verification of enclosure temperature. Evaluate the selected S-100 with its actual monitoring and communication electronics. Pump motors, valves, pressure excitation and protective shutdown remain independently engineered functions.
Potential S-100 Applications
Automatic screw-feeder supervisory station
An automatic screw-feeder supervisory station may assess a qualified S-100 suffix for compatible supervisory logic and display boards. Check voltage, electronic-load demand and interruption response. Screw-driving tools, feeder motors, pneumatic valves and fastening quality require separate power and process validation.
Tube end-former operator interface
Evaluate an exact S-100 model for compatible operator-interface and communication electronics beside a tube end-forming machine. Verify the electrical compartment and board requirements. Forming drives, hydraulic power, clamping and safeguarding remain separately designed functions.
Warehouse pick-to-light controller
A warehouse pick-to-light controller may consider a selected S-100 output for compatible local controller and network-interface boards. Verify the individual boards, branch protection and thermal environment. This does not approve direct connection of arbitrary lamps or LED strips, distributed wiring lengths or a complete warehouse installation.
Industrial audio-announcement rack
An industrial audio-announcement rack may evaluate a qualified S-100 version for compatible routing, status and communication electronics. Confirm the exact board voltage and startup demand. Audio power amplifiers, speaker-line voltage, emergency communication and acoustic performance need separately qualified systems.
S-100 Technical FAQs
Which exact output models and current ranges are listed?
S-100-5 lists 5V 0~20A; S-100-12 lists 12V 0~8.5A; S-100-18 lists 18V 0~5.5A; S-100-24 lists 24V 0~4.5A; S-100-36 lists 36V 0~3A; S-100-48 lists 48V 0~2.1A. These are separate single-output models, not simultaneous rails. Select one exact suffix for the connected board.
Does the 100W designation establish every continuous operating point?
The family designation and the printed current ranges are separate entries. Do not calculate a replacement continuous wattage from their endpoints or assume maximum output at every input and temperature. Confirm the ordered suffix’s continuous and startup duty. The printed zero lower bounds do not independently establish minimum-load or no-load acceptance.
Is the AC input automatically selected?
The input entry is 90~132VAC/180~264VAC by switch, with 254~370VDC and 47~63Hz also listed. This requires manual AC selection, not an automatic universal-input assumption. Confirm the actual switch setting and connection instructions before energizing, including any proposed DC-input use.
What does the DC-voltage adjustment range establish?
All listed versions have ±10% DC-voltage adjustment. Check the connected board’s voltage limits and the exact model’s accepted duty before adjusting. This entry does not establish regulated-current output, dimming, battery charging or arbitrary programmable operation.
What ripple and line/load stability apply to each suffix?
S-100-5: 75mVp-p, line stability ±0.5%, load stability ±0.5%; S-100-12: 100mVp-p, line stability ±0.3%, load stability ±0.3%; S-100-18: 100mVp-p, line stability ±0.2%, load stability ±0.2%; S-100-24: 100mVp-p, line stability ±0.2%, load stability ±0.2%; S-100-36: 100mVp-p, line stability ±0.2%, load stability ±0.2%; S-100-48: 100mVp-p, line stability ±0.2%, load stability ±0.2%. Line stability and load stability are separate parameters. These entries do not specify a ripple measurement bandwidth or cable method.
Which efficiency and cold-start entries apply to this family?
S-100-5: 78%; S-100-12: 81%; S-100-18: 84%; S-100-24: 84%; S-100-36: 84%; S-100-48: 84%. Cold-start current is 30A/115VAC and 60A/230VAC. These transients apply at their stated input voltages; they are not continuous input current. Efficiency measurement conditions beyond the printed entries need confirmation.
How does overload protection recover?
The overload entry is 105%~150%, cutting off output with automatic recovery. It is not a continuous overload allowance or a replacement for branch and cable protection. Evaluate the electronics’ restart behavior and repeated-fault response in the completed equipment.
Does overvoltage shutdown require re-powering?
The overvoltage entry is 115%~135%, shutting down output voltage and requiring re-powering to recover. This differs from automatic overload recovery. Downstream protection and safe equipment restart require their own verification.
Which setup, rise and hold-up times and test conditions are stated?
Setup, rise and hold-up are 200ms, 50ms and 20ms at 230VAC and full load. The stated input and full-load conditions apply to this timing entry. Full-load timing does not establish full-temperature full-load operation, an uninterrupted supply or the same response at all input voltages and loads.
What working temperature, dimensions and mass are listed?
The entries are -10°C~+50°C, 199×98×38mm and 0.6kg. Check the actual compartment temperature, mounting, terminal access and cooling arrangement. These entries do not provide an ingress rating, humidity limit or complete full-load derating curve.
What withstand and isolation-resistance entries are printed?
Withstand entries are I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute, without a printed AC/DC qualifier. Isolation resistance is I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ. These component test entries do not establish certification scope or finished-equipment approval.
What terminal order does the drawing show?
The drawing labels pins 1 and 2: AC input; pin 3: GND; pins 4 and 5: DC output-V; pins 6 and 7: DC output+V. Confirm the delivered terminal markings, connection instructions, conductor ratings and protective bonding before wiring. The AC labels do not establish DC-input terminal assignments. The duplicated signed output terminals do not establish independent rails, permitted strapping or conductor current allocation.
¿Cuáles son los mejores productos de fuentes de alimentación para su empresa?
Impulsa tu negocio con productos de suministro de energía de calidad WEHO.