| Especificación | S-1200-12 | S-1200-24 | S-1200-36 | S-1200-48 |
| Tensión de salida CC, corriente | 12V 0 ~ 100A | 24V 0 ~ 50A | 36V 0 ~ 33A | 48V 0 ~ 25A |
| Ola y ruido | 150mVp-p | 180mVp-p | 180mVp-p | 240mVp-p |
| Estabilidad del cable de entrada | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Estabilidad de carga | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Eficiencia | 80% | 85% | 85% | 87% |
| Rango ajustable para voltaje CC | ±10% | ±10% | ±10% | ±10% |
| Rango de voltaje de entrada | 100 ~ 132VAC/200 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz | |||
| Corriente de impacto | Corriente de arranque en frío 45A/230VAC | |||
| Protección contra sobrecarga | 105% ~ 135% cut off the output, automatic recovery | |||
| Otra protección | Not specified in this datasheet (overvoltage threshold and short-circuit recovery mode are not stated). | |||
| Preparar, levantarse, esperar el tiempo | 2000ms, 50ms, 20ms/230VAC at full load | |||
| Voltaje de soporte | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||
| Resistencia de aislamiento | I/P-O/P, I/P-FG, O/P-FG: 500 VCC/100 MΩ | |||
| Temperatura de trabajo | -10°C ~ +50°C | |||
| Dimensión | 291 × 132 × 68mm | |||
| Peso | 2,65 kilos | |||
| Embalaje | 37.5 × 31 × 25.5CM/6PCS/16kg | |||
Serie S-1200W fuente de alimentación de conmutación simple normal
WEHO S-1200 is a single-output switching power supply with separate 12V, 24V, 36V and 48V variants. The output table supports a voltage-specific comparison for electronic bays in production equipment, rather than a blanket power allocation to every machine load. Provide the electronics specification and thermal arrangement so the proposed variant can be assessed for the actual duty.
Si tiene alguna pregunta, no dude en contactarnos en Correo electrónico: [email protected]
- Descripción
Why Choose S-1200
Select the required output, not just the family label
The S-1200-12 column lists 12V with a 0 ~ 100A current range. The output-specific entries let a buyer compare the required rail rather than transfer a current figure from another voltage. The family label is not approval for continuous operation at an arbitrary voltage/current combination.
Plan selectable input at the equipment site
AC input is 100 ~ 132VAC or 200 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. The explicit input bands help procurement distinguish a switch-selected unit from an automatically ranging supply. Confirm the delivered selector instructions and site supply before energizing; the printed DC range is not a DC wiring procedure.
Reserve an identifiable equipment envelope
The listed body dimensions are 291 × 132 × 68mm and the listed weight is 2.65kg. These entries support an initial cabinet-envelope and handling review. Allow separate room for studs, cable bends, ventilation and servicing; the body size alone does not establish mounting fit or terminal clearance.
Evaluate adjustment against the real electronics tolerance
The DC-voltage adjustment entry is ±10% for every listed output. This provides a defined adjustment entry for a matched rail, but the connected boards must tolerate the final setting and transients. Adjustment is not an additional current rating or a substitute for load qualification.
S-1200 Features and Selection Benefits
Separate line and load stability entries
Inlet-wire stability and load stability are each ±0.5% for every listed output. These figures help compare steady-state regulation requirements. They do not describe output accuracy over every temperature or dynamic step-load performance.
Output-specific wave-and-noise figures
The wave-and-noise entries are S-1200-12: 150mVp-p; S-1200-24: 180mVp-p; S-1200-36: 180mVp-p; S-1200-48: 240mVp-p. Compare the selected column with the electronics noise allowance. Sensitive measurement or communication circuits still need application-level evaluation; no unprinted bandwidth or test fixture is assumed.
Efficiency values tied to each suffix
The efficiency entries are S-1200-12: 80%; S-1200-24: 85%; S-1200-36: 85%; S-1200-48: 87%. Use the relevant entry for a preliminary power-loss discussion, not as a measured result for the finished cabinet. The actual input, load, duty cycle and internal temperature govern the thermal review.
A stated overload response, without extra protection promises
Overload protection is listed at 105% ~ 135% with output cutoff and automatic recovery. No separate overvoltage threshold or short-circuit recovery mode is specified on this sheet. Automatic recovery must be considered in the machine restart strategy; it does not qualify the supply as a protective control or eliminate independent branch protection.
Typical S-1200 Service Conditions
Check heat accumulation through palletizing cycles
The printed working-temperature range is -10°C ~ +50°C. At a bag-palletizing robot cell, assess compatible pallet-pattern and production-status electronics at the actual cabinet hot spot and duty cycle. Keep packaging dust controlled while maintaining the required ventilation. Robot motion, gripping and protective controls are independent systems; no continuous-duty curve is supplied by the temperature entry.
Match input during die-press installation
AC input is 100 ~ 132VAC or 200 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. For a flatbed die-cutting press, verify the incoming supply and manual selector before energizing compatible job-selection and maintenance-record electronics. Support cables away from platen motion and prevent scrap from entering the electrical bay. Press actuation, sheet drives and guarding circuits remain separately engineered.
Assess electronic switch-on at drum handling
The only printed cold-start entry is 45A at 230VAC; no 115VAC cold-start value is given. At a cable-drum rewinding station, review the input branch when cable-job and production-record electronics restart with adjacent equipment. Do not invent a lower-input cold-start value from the stated test point. Support wiring clear of rotating drums; drum power, traverse and tension functions are not assigned to this supply.
Separate powder handling and restart decisions
Setup, rise and hold-up times are 2000ms, 50ms and 20ms, respectively, at 230VAC at full load. For an industrial ribbon-blender line, protect compatible batch-recipe and maintenance-display electronics from process material and confirm the real thermal conditions. Evaluate input interruption and overload recovery without relying on the timing entry for process continuity. Mixer and dosing power and protective functions require independent engineering, including the process-area environment.
Potential S-1200 Equipment Applications
Automatic pallet-strapping arch
An automatic pallet-strapping arch may evaluate a qualified S-1200 variant for compatible 24V-input package-recipe and cycle-record electronics, not strap motors, sealing heaters or pallet drives. Confirm the interface voltage, restart behavior and branch load over repeated packages. Strapping tension, sealing heat and pallet movement require independently selected systems. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.
Ceramic-part polishing carousel
A ceramic-part polishing carousel may evaluate a qualified S-1200 variant for compatible 24V-input recipe-index and part-count electronics, not polishing motors, slurry pumps or protective controls. Check electronics demand, noise tolerance and a dry protected compartment away from abrasive slurry. Surface finish, motor torque and slurry handling are not established by this proposal. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.
Tyre inspection rig
A tyre inspection rig may evaluate a qualified S-1200 variant for compatible 24V-input product-record and non-measurement display electronics, not calibrated measurement, clamping actuation or wheel drives. Select the electronics rail only after checking its input tolerance and noise limits. The supply is not a calibrated reference and does not establish inspection accuracy, clamping force or wheel-drive capability. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.
Industrial book-sewing line
An industrial book-sewing line may evaluate a qualified S-1200 variant for compatible 12V-input job-file and operator-display electronics, not sewing drives, clamp actuators or protective functions. Match the display and file-interface voltage, startup demand and local cabinet conditions. Sewing accuracy, clamp force and transport motion are outside the proposed DC role. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.
S-1200 Technical FAQs
Which S-1200 variants are printed, and what does its power-class label mean?
S-1200-12: 12V, 0 ~ 100A; S-1200-24: 24V, 0 ~ 50A; S-1200-36: 36V, 0 ~ 33A; S-1200-48: 48V, 0 ~ 25A. The summary uses the 1200W single-output power-class label. A printed current range is not independently approved rated continuous current. Do not infer a minimum-load rule, a full-temperature continuous power rating or parallel capability from the range or from voltage multiplied by its upper bound.
How is the S-1200 input selected?
AC input is 100 ~ 132VAC or 200 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. The AC bands are not one uninterrupted automatic-ranging input. Verify selector position with power isolated using the delivered instructions. Confirm any intended DC-input connection and polarity separately; the listed DC range does not establish those instructions.
What cold-start input condition is stated for S-1200?
The only printed cold-start entry is 45A at 230VAC; no 115VAC cold-start value is given. Use that input association for upstream switch-on assessment and check aggregate inrush with other cabinet loads. It is not the normal input current, a fuse recommendation or proof of behavior on the other AC band.
What setup, rise and hold-up conditions are stated for S-1200?
Setup, rise and hold-up times are 2000ms, 50ms and 20ms, respectively, at 230VAC at full load. The three values have distinct functions and belong to that printed input/full-load condition. They do not establish stored-data retention, uninterrupted process operation or full-temperature full-load duty; verify the equipment response to loss and return of input.
How do S-1200 wave-and-noise entries vary by output?
S-1200-12: 150mVp-p; S-1200-24: 180mVp-p; S-1200-36: 180mVp-p; S-1200-48: 240mVp-p. Assess sensitive electronic loads against the figures for the selected model. The page does not give a bandwidth, probe arrangement or separate dynamic-noise test condition; qualify the actual electronics and routing rather than inventing those conditions.
How should S-1200 stability and adjustment figures be used?
Inlet-wire stability and load stability are each ±0.5% for every listed output. The DC-voltage adjustment entry is ±10% for every listed output. Line stability, load stability and adjustment describe different attributes. Neither the stability values nor the available adjustment proves an arbitrary electronics tolerance, output accuracy over temperature or permissible extra current after voltage adjustment.
Which efficiency figures belong to the S-1200 suffixes?
S-1200-12: 80%; S-1200-24: 85%; S-1200-36: 85%; S-1200-48: 87%. These are output-column entries, not measured cabinet efficiency under the proposed load. Confirm the operating input, output, loading and thermal arrangement before using the figure in a final thermal or energy calculation.
What protection response is specified for S-1200?
Overload protection is listed at 105% ~ 135% with output cutoff and automatic recovery. No separate overvoltage threshold or short-circuit recovery mode is specified on this sheet. The sheet does not explicitly define the percentage reference or a separate fault-current duty. Do not treat automatic recovery as a safety function, permission for unattended restart or a replacement for correctly engineered branch protection.
What environment does the S-1200 sheet describe?
The printed working-temperature range is -10°C ~ +50°C. Storage temperature, working humidity and storage humidity are not specified on this sheet. Confirm the enclosure hot spot, ventilation, contamination and actual electronic load. The working-temperature entry is not a derating curve or approval for full load across that range, and it supplies no ingress rating or process-area approval.
What mechanical and shipping entries are listed for S-1200?
The listed body dimensions are 291 × 132 × 68mm and the listed weight is 2.65kg. Packing is listed as 37.5 × 31 × 25.5CM/6PCS/16kg. The drawing separately marks body and hole references; do not combine them into an unprinted overall cable or stud clearance. Confirm the delivered unit, mounting details and current shipping configuration before final enclosure or logistics design.
What can be taken from the S-1200 terminal drawing?
The front drawing labels the two output studs POS(+) and NEG(-), with a 2-M6 callout; the input view labels FG, N and L beside AC INPUT. No numbered pin legend is printed. The drawing also marks the LED and voltage-adjustment point. The input-strip view shows five screw-like circular positions, but only the inner FG, N and L positions are labelled; the two unlabelled end positions are not assigned an electrical function here. Confirm the delivered variant and terminal arrangement before wiring. FG and output signs alone do not establish the system bonding scheme, output-isolation approval or permitted interconnection.
What withstand and isolation entries are printed for S-1200?
Withstand entries are I/P-O/P: 1.5kV, I/P-FG: 1.5kV and O/P-FG: 0.5kV for 1minute, without a printed AC/DC test qualifier. Isolation resistance is listed as 500VDC/100MΩ for I/P-O/P, I/P-FG and O/P-FG. No AC/DC test-voltage qualifier is stated for these kV entries. These entries are not a certificate, an instruction to perform a field high-voltage test, a touch-safety classification or approval of an equipment grounding arrangement.