Fuente de alimentación conmutada de 120 W de CA a CC de 12 V

Single-Output Family: LRS-120 is a 120W-class family with 12V, 15V, 24V and 48V versions; listed current ranges are 0~10A, 0~8A, 0~5A and 0~2.5A respectively.
Input Range: 85~264VAC or 120~373VDC, 47~63Hz.
Adjustment and Stability: DC output-voltage adjustment is ±10%; line and load stability are both ±0.5%.
Protection: Overload protection at 110%~150%, cutting off the output with automatic recovery; overcurrent and short-circuit protection.
Compact Dimensions: 129×97×30mm, with a 30mm profile. Listed working temperature is -20℃ to +70℃.

Overview

The LRS-120 is a single-output AC/DC power supply. Its proposed role is a local DC branch for compact equipment interfaces, sensors and media-control electronics. The specified overall dimensions are 129 × 97 × 30 mm. The shallow body gives designers a defined starting footprint for tabletop and enclosed equipment bases. Specify the load input and operating cycle when selecting the output model.

Why Choose LRS-120?

Fit compact workcells

The specified overall dimensions are 129 × 97 × 30 mm. This footprint can be assessed early in a benchtop base, avoiding a late clash between electronics, pneumatic hardware and service access.

Choose a defined electronics branch

The LRS-120 offers separate 12 V, 15 V, 24 V and 48 V models: LRS-120-12, LRS-120-15, LRS-120-24 and LRS-120-48, respectively. A dedicated variant makes the load voltage explicit rather than treating the product as a multi-rail output module.

Screen the upstream source

The input specification lists 85–264 VAC / 120–373 VDC and 47–63 Hz. The specified window lets the designer screen an AC mains or suitable DC source before upstream protection is selected.

Budget steady-state regulation

Line regulation and load regulation are each listed as ±0.5%. Separate line and load figures support an initial voltage budget that still includes distribution drop and load transients.

Features, Benefits & Advantages

Característica Benefit in equipment design
Model-specific output ranges The printed output-current ranges are 0–10 A, 0–8 A, 0–5 A and 0–2.5 A for LRS-120-12, LRS-120-15, LRS-120-24 and LRS-120-48, respectively. The individual ranges help screen combined sensor and interface demand before enclosure and transient checks.
Published ripple-and-noise figures The listed ripple-and-noise values are 120 mVp-p, 120 mVp-p, 150 mVp-p and 200 mVp-p for LRS-120-12, LRS-120-15, LRS-120-24 and LRS-120-48, respectively. Use these as preliminary comparison values; a sensitive receiver still needs a load-side noise assessment.
Bounded voltage adjustment The DC-voltage adjustment range is listed as ±10%. Adjustment is a commissioning consideration for a matched load, not a substitute for selecting its nominal input voltage.
Fault response for branch planning Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. Assess what the connected electronics do during output cutoff and restoration.
Especificación LRS-120-12 LRS-120-15 LRS-120-24 LRS-120-48
Tensión de salida CC, corriente 12V 0~10A 15V 0~8A 24V 0~5A 48V 0~2.5A
Ola y ruido 120mVp-p 120mVp-p 150mVp-p 200mVp-p
Estabilidad del cable de entrada ±0,5% ±0,5% ±0,5% ±0,5%
Estabilidad de carga ±0,5% ±0,5% ±0,5% ±0,5%
Eficiencia 86% 88% 88% 90%
Rango ajustable para voltaje CC ±10% ±10% ±10% ±10%
Rango de voltaje de entrada 85~264VAC / 120~373VDC, 47~63Hz
Corriente de impacto Corriente de arranque en frío 50A/230VAC
Protección contra sobrecarga 110%~150%corta la salida, recuperación automática
Otra protección Protección contra sobrecorriente/protección contra cortocircuitos
Timing (setup / rise / hold-up) 230VAC: 500ms, 30ms; 115VAC: 500ms, 30ms. No separate hold-up time is specified.
Voltaje de soporte I/P-O/P:1,5 kV I/P-FG:1,5 kV O/P-FG:0,5 kV 1 minuto
Resistencia de aislamiento I/P-O/P I/P-FG O/P-FG: 100M ohmios/500VDC/25℃/70%RH
Temperatura de trabajo -20℃~+70℃
Dimensión 129×97×30mm
Peso 0,34 kg
Embalaje 42,5×32,5×19,5CM/45PCS/16kg

Mechanical dimensions

LRS-120 — dimensions in millimetres
Body length129 mm
Body width97 mm
Body height30 mm

The body dimensions and mounting-hole dimensions are different references. The vector drawing below retains the dimensions printed in the WEHO original.

On a small screen, swipe the drawing horizontally to inspect every dimension. No separate drawing image or script download is required.

Exact mechanical drawing from the WEHO original. Units: mm. Use the printed body, mounting and hole dimensions separately.

Typical Service Conditions

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


Select 90–132VAC or 180–264VAC manually before energizing, then verify the chosen DC output and polarity.

Input matching: LRS-120 versus the selector example

The illustration shows the LRS-350 manual-range example; do not transfer its 90–132/180–264 VAC bands to LRS-120. The input specification lists 85–264 VAC / 120–373 VDC and 47–63 Hz. The input range does not document a selector switch or an automatic range-switching mechanism. Match the selected DC version to every connected input, then include simultaneous demand and startup transients before energising the equipment. The planning image is a representative LRS-series example, not an exact-model wiring diagram.

LRS-350 manual-selector planning example; use LRS-120 input bands, selection instructions and output options, not the example labels.


Keep fan and ventilation openings unobstructed inside a cabinet selected for the actual environment. Arrows show conceptual airspace, not a measured airflow path.

LRS-120 enclosure and service-space planning

The specified overall dimensions are 129 × 97 × 30 mm. The listed product weight is 0.34 kg. Reserve additional space for terminal access, conductor routing and the host equipment's airflow; the case outline is not a clearance allowance.

LRS-series cabinet-space concept; the exact case, cooling method and mounting are defined by this model's own technical data.


The −20°C to +70°C working range does not establish full output at every temperature. Use the selected version’s load and thermal limits.

Temperature and duty-cycle assessment for LRS-120

The specified working-temperature range is -20°C to +70°C. The sheet does not provide a derating curve, a cooling method or evidence of full-load operation across that temperature range. Measure the temperature at the installed supply and review the longest expected duty cycle. Keep vents unobstructed; do not substitute room temperature for the operating temperature inside the equipment.

LRS-350 temperature-planning example, not a measured derating curve or a replacement for LRS-120 operating limits.


Functional power-planning illustration only. Have qualified personnel select protection, follow terminal markings and verify safe isolation before work.

LRS-120 fault recovery and protected installation

Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. Have a qualified installer check terminal identification, protective earthing and branch protection for the actual assembly. Coordinate restart behaviour with the equipment controls rather than treating supply recovery as a safety function.

Functional power-planning illustration only; follow the exact model's terminal identification and qualified installation instructions.



Application Industries

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


AI illustration of an illuminated retail lightbox and storefront at blue hour.

Retail sign-control and LED-module branches

A modular retail sign can use a compatible LRS-120 version for a defined set of control and constant-voltage module loads. Include every simultaneously lit module and its startup demand. Use the actual protected compartment temperature and do not treat the storefront picture as an outdoor installation approval.

The LRS-120-12 column lists 12 V and an output-current range of 0–10 A.

AI application concept — retail signage, not an installation record for this product.


AI illustration of complete self-service parcel lockers and a central pickup screen in a bright indoor lobby.

Parcel-terminal interface electronics

For an indoor pickup kiosk, assess LRS-120 for the media-control and door-interface branch after checking all accepted input voltages. Separate screen power, lock transients and any charging circuit as needed. The chosen output is not a communications-power protocol.

The LRS-120-24 column lists 24 V and an output-current range of 0–5 A.

AI application concept — parcel-terminal electronics, not an installation record for this product.


AI illustration of a complete guarded automatic carton-packing machine on a production floor.

Carton-packaging auxiliary electronics

On a carton line, an LRS-120 branch may supply compatible controller interfaces, registration sensing and operator indicators. Establish the simultaneous demand during starting and recovery, including downstream conversion. Drives and heating circuits keep their own supply and protective arrangements.

The LRS-120-15 column lists 15 V and an output-current range of 0–8 A.

AI application concept — carton-packaging auxiliary electronics, not a complete-machine power claim.


AI illustration of an electronics inspection workbench with a supported PCB fixture and optical inspection equipment.

Electronics-fixture auxiliary interfaces

For a multi-function inspection fixture, evaluate LRS-120 for compatible sequence-control and status electronics. Check each optical device and illumination driver against the selected rail and its startup profile. Keep DUT bias, calibrated excitation and measurement accuracy outside this auxiliary-supply claim.

The LRS-120-48 column lists 48 V and an output-current range of 0–2.5 A.

AI application concept — electronics-fixture interfaces; no measurement-performance or installed-model claim.



Preguntas frecuentes

Which output-voltage models does the LRS-120 provide?

The LRS-120 offers separate 12 V, 15 V, 24 V and 48 V models: LRS-120-12, LRS-120-15, LRS-120-24 and LRS-120-48, respectively. Each model is a single-output choice; the alternatives are not simultaneous rails on the same unit.

How are the LRS-120 current ranges and series-power statement distinguished?

The printed output-current ranges are 0–10 A, 0–8 A, 0–5 A and 0–2.5 A for LRS-120-12, LRS-120-15, LRS-120-24 and LRS-120-48, respectively. The series summary states "Single output: power 120W". The sheet gives no separate continuous-wattage row for each output variant; the summary power and the printed current endpoints must remain separate selection facts. Continuous-load acceptance must keep both source statements in view, with transient demand and thermal conditions reviewed for the actual design.

Which input range is specified for the LRS-120?

The input specification lists 85–264 VAC / 120–373 VDC and 47–63 Hz. The input range does not document a selector switch or an automatic range-switching mechanism. Confirm source behavior and input wiring from the applicable product documentation before integration.

What body size and weight are listed for the LRS-120?

The specified overall dimensions are 129 × 97 × 30 mm. The listed product weight is 0.34 kg. Overall dimensions support space planning, not mounting-hole, terminal-clearance or enclosure-access dimensions.

How does LRS-120 efficiency vary by output model?

The listed efficiencies are 86%, 88%, 88% and 90% for LRS-120-12, LRS-120-15, LRS-120-24 and LRS-120-48, respectively. The sheet does not give the efficiency or ripple measurement conditions, so these figures are not a complete equipment-level performance guarantee. Use the figure for the selected output model, then assess losses under the actual equipment load.

Which ripple-and-noise figures are listed for the LRS-120?

The listed ripple-and-noise values are 120 mVp-p, 120 mVp-p, 150 mVp-p and 200 mVp-p for LRS-120-12, LRS-120-15, LRS-120-24 and LRS-120-48, respectively. The sheet does not give the efficiency or ripple measurement conditions, so these figures are not a complete equipment-level performance guarantee. A sensitive camera or measurement interface needs a load-side noise check with the actual cabling and other loads operating.

What do the LRS-120 line- and load-regulation figures describe?

Line regulation and load regulation are each listed as ±0.5%. These are separate line- and load-regulation figures, not an additional overall output-voltage tolerance. Cable drop and load-step response remain separate parts of the connected-equipment voltage budget.

What does the LRS-120 DC-voltage adjustment specification establish?

The DC-voltage adjustment range is listed as ±10%. The adjustment specification does not establish dimming, programmability or a constant-current operating mode. The connected equipment input window limits the permissible final setting.

How does LRS-120 overload protection respond?

Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. The overload threshold is not an extra continuous-load allowance, and recovery is not a machine safety or redundant-power function.

Which startup figures are listed for the LRS-120?

The listed cold-start current is 50 A at 230 VAC. The setup/rise row gives 500 ms and 30 ms at 230 VAC, and 500 ms and 30 ms at 115 VAC. The row includes hold-up in its heading but prints no separate hold-up duration or full-load test condition. Upstream protection, simultaneous energization and electronics-ready sequencing require system-level assessment.

What working-temperature boundary is documented for the LRS-120?

The specified working-temperature range is -20°C to +70°C. The sheet does not provide a derating curve, a cooling method or evidence of full-load operation across that temperature range. Validate compartment temperature, airflow and duty cycle for the actual equipment instead of assigning full-load performance at the upper limit.

Which insulation test figures are listed for the LRS-120?

The withstand figures are 1.5 kV from input to output, 1.5 kV from input to FG and 0.5 kV from output to FG, each for 1 minute. Isolation resistance is listed as 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. These test figures do not establish an ingress rating or product certification. Assembly earthing, protective barriers and end-equipment conformity need their own verification.