Product Categories

NDR-120 Series 120W Slim Industrial DIN Rail Power Supply (NDR-120-12 / NDR-120-24 / NDR-120-48)

NDR-120 is a single-output DIN-rail switching power supply with separate 12V, 15V, 24V and 48V models. The specified input range is 85–264VAC or 120–370VDC, with 47–63Hz AC input. Working temperature is -10°C to +50°C. Check the selected output rating and installation conditions before ordering.

Si tiene alguna pregunta, no dude en contactarnos en Correo electrónico: [email protected]

Modelo NDR-120-12 NDR-120-15 NDR-120-24 NDR-120-48
Voltaje de salida CC 12V 15V 24V 48V
Corriente de salida nominal 10A El 8A 5A 2.5A
Rango de corriente de salida 0 y 10A 0 y 8a 0 y 5a 0-2.5A
Ola y ruido 100mVp-p 120mVp-p 120mVp-p 150mVp-p
Estabilidad de entrada ±0,5% ±0,5% ±0,5% ±0,5%
Estabilidad de carga ±0,5% ±0,5% ±0,5% ±0,5%
Potencia de salida CC 120W 120W 120W 120W
Eficiencia 86% 88% 88% 89%
Rango ajustable para voltaje CC 10,8 ~ 13,2 V 13,5 y 16,5 V 21.6~26.4V 43,2 ~ 52,8 V
Rango de voltaje de entrada de CA 85–264VAC / 120–370VDC; AC frequency: 47–63Hz
Inicio Inrush Current Cold-start current: 30A/115VAC; 60A/230VAC
Protección contra sobrecarga 105%~150% cut off the output, automatic recovery
Protección de sobrevoltaje 120%~140% shut down O/P voltage, re-power on to recover
Tiempo de preparación, ascenso y espera 1200ms, 60ms, 60ms/230VAC (at full load)
Tensión soportada I/P–O/P: 1.5kV; I/P–FG: 1.5kV; O/P–FG: 0.5kV; duration: 1 minute. Test waveform requires confirmation.
Resistencia de aislamiento Entrada y salida interna: Entrada y caja, Salida y caja: 500VDC/100M Ω
Temperatura de trabajo -10°C to +50°C
Dimensión general 40×125.2×113.5mm
Peso 0.6Kgs
Estándares de seguridad Ceñudo

Temperature derating

Permissible load versus ambient temperature for NDR-120.

Swipe the curve horizontally to inspect all labels.

Permissible percentage load versus ambient temperature. Follow the plotted vertical mounting and input/output-voltage conditions; remain within WEHO stated product limits. No extrapolation.
Percentage load refers to the selected WEHO variant's rated output. Stay within the specification table's working-temperature and absolute output limits; the wider horizontal axis does not expand those ratings. Follow the vertical mounting and all input/output-voltage conditions printed in the curve. The plotted voltage cases are 12V, 24V and 48V. For a 15V version, obtain a confirmed temperature/load limit for that exact version before selecting a continuous load.

Overload protection: 105%~150%, output cut-off with automatic recovery. Overvoltage protection: 120%~140%, output shutdown; re-power on to recover.

Nuestros productos tienen una larga vida útil, son altamente confiables y muy eficientes.

DIN-rail format; dimensions: 40×125.2×113.5mm.

This product has a universal AC input that is a full range

3Years Warranty

¿Cuáles son los mejores productos de fuentes de alimentación para su empresa?

Impulsa tu negocio con productos de suministro de energía de calidad WEHO.

Pregúntale a un experto
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.