| Especificación | S-120-12 | S-120-15 | S-120-18 | S-120-24 | S-120-36 | S-120-48 |
| Tensión de salida CC, corriente | 12V 0 ~ 10A | 15V 0 ~ 8A | 18V 0 ~ 6.7A | 24V 0 ~ 5A | 36V 0 ~ 3.3A | 48V 0 ~ 2.5A |
| Ola y ruido | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Estabilidad del cable de entrada | ±0,3% | ±0,3% | ± 0.2% | ± 0.2% | ± 0.2% | ± 0.2% |
| Estabilidad de carga | ±0,3% | ±0,3% | ± 0.2% | ± 0.2% | ± 0.2% | ± 0.2% |
| Eficiencia | 81% | 82% | 84% | 84% | 84% | 84% |
| Rango ajustable para voltaje CC | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
| Rango de voltaje de entrada | 90 ~ 132VAC/180 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz | |||||
| Corriente de impacto | Corriente de arranque en frío 30A/115VAC 60A/230VAC | |||||
| Protección contra sobrecarga | 105% ~ 150% cut off the output, automatic recovery | |||||
| Protección contra sobretensión | 115% ~ 135% shut down O/P voltage, re-power on to recover | |||||
| Configurar, levantarse, mantener el tiempo de actividad | 200ms, 50ms, 20ms/230VAC at full load | |||||
| Voltaje de soporte | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||||
| Resistencia de aislamiento | I/P-O/P, I/P-FG, O/P-FG: 500 VCC/100 MΩ | |||||
| Temperatura de trabajo | -10°C ~ +50°C | |||||
| Dimensión | 199 × 98 × 38mm | |||||
| Peso | 0.6kg | |||||
| Embalaje | 43 × 32.5 × 24CM/30PCS/18kg | |||||
S-120W series normal single switching power supply
WEHO S-120 provides six separate single-output alternatives from 12V to 48V in a 199×98×38mm enclosure. The 120W-designated family includes 15V and 18V versions, with output-specific stability and efficiency figures for equipment-electronics selection. AC input is 90~132VAC/180~264VAC by switch, and 254~370VDC is also listed. Evaluate one exact suffix for compatible local controller, status or communication boards. The printed current ranges do not establish a continuous-power guarantee; verify startup, cooling, load and terminal conditions in the complete equipment.
Si tiene alguna pregunta, no dude en contactarnos en Correo electrónico: [email protected]
- Descripción
Why Choose the S-120?
Distinguish the 15V and 18V electronic-load options
S-120-15 lists 15V 0~8A and S-120-18 lists 18V 0~6.7A. Match the board’s required voltage to the actual suffix instead of assuming these models are interchangeable. Verify the actual continuous and transient electronic demand against the selected suffix’s printed current range.
Use the correct stability figure for low-voltage versions
The 12V and 15V variants each list ±0.3% line and load stability. The 18V, 24V, 36V and 48V variants each list ±0.2% for both. This supports a model-specific tolerance review without promising the best stability across every output or installation.
Evaluate the 24V and 36V options without a derived rating
S-120-24 lists 24V 0~5A and S-120-36 lists 36V 0~3.3A. Their different voltage/current entries help identify candidates for compatible boards. Neither the 120W family designation nor multiplication of an endpoint establishes a replacement continuous rating at every operating condition.
Plan reset and service space together
The 199×98×38mm outline, 0.6kg mass and 20ms hold-up entry at 230VAC and full load belong in the equipment-integration review. Verify mounting, terminal access, thermal conditions and board reset behavior. A dimensional match to S-100 does not establish electrical interchangeability.
S-120 Features
Six separate output-voltage alternatives
S-120-12 lists 12V 0~10A; S-120-15 lists 15V 0~8A; S-120-18 lists 18V 0~6.7A; S-120-24 lists 24V 0~5A; S-120-36 lists 36V 0~3.3A; S-120-48 lists 48V 0~2.5A. They are separately ordered single-output models; this set does not include a 5V version.
Common ripple with model-specific efficiency
All six outputs list 100mVp-p ripple and ±10% DC-voltage adjustment. Efficiency is 81% at 12V, 82% at 15V and 84% at 18V, 24V, 36V and 48V. Evaluate actual board tolerance and enclosure heating rather than assuming efficiency is a load-independent guarantee.
Input and timing entries with explicit conditions
The input entry gives 90~132VAC/180~264VAC by switch, 254~370VDC and 47~63Hz. Cold-start current is 30A/115VAC and 60A/230VAC. Setup, rise and hold-up are 200ms, 50ms and 20ms at 230VAC and full load. Verify the selector setting and evaluate startup under the stated conditions for equipment integration.
Separate overload recovery from overvoltage restart
Overload at 105%~150% cuts off output with automatic recovery. Overvoltage at 115%~135% shuts down output and requires re-powering. Check connected-board restart behavior and protective coordination; these responses do not qualify sustained fault operation or the safety of a complete machine.
Typical Service Conditions
Keep ink-system monitoring away from fluid paths
An industrial ink-circulation monitoring rack needs a dry electrical compartment isolated from ink spills and cleaning fluid. A selected S-120 would serve only compatible local monitoring and communication boards after voltage and load checks. Circulation pumps, printheads and fluid-process controls require separately qualified supplies and protection.
Place a kiln program terminal outside the hot zone
A ceramic-kiln program terminal may evaluate a suitable S-120 output for compatible user-interface and communication electronics in a controlled electrical area. Verify the actual compartment temperature; -10°C~+50°C is not a full-load derating curve. Kiln heaters, contactors and overtemperature protection remain separate functions.
Separate separator alarm electronics from field coils
A magnetic-particle separator alarm station should segregate its electronics and wiring from high-current field-coil circuits. Check the actual board load, noise tolerance and thermal environment before selecting S-120. Electromagnets, vibrating feeders and machine-stop functions require independent power and safety design.
Protect production records at a press console
A servo-hydraulic press production-record console needs verified board startup, interruption response and data-retention behavior. Consider S-120 only for compatible local recording and communication electronics. Press drives, hydraulic valves, pressure references and operator protection are not covered by this role.
Potential S-120 Applications
Cable-drum winding operator stand
Evaluate an exact S-120 suffix for compatible display, status and communication boards at a cable-drum winding operator stand. Confirm local electronic demand and protected cable routing. Winding motors, traverses, tension actuators and machine safeguards require independently qualified systems.
Multiport serial device-server rack
A multiport serial device-server rack may assess a qualified S-120 version for compatible local processing and communication boards. Verify voltage, startup demand, ripple tolerance and compartment heat. Port isolation, external device power, network security and site-wide backup behavior remain separate design requirements.
Water-recirculation chiller status station
A water-recirculation chiller status station may consider an exact S-120 model for compatible local indication and communication electronics in a dry compartment. Check moisture protection, actual temperature and board demand. Compressors, pumps, valves and temperature-control performance need separately qualified power and controls.
Eddy-current tube-inspection operator console
An eddy-current tube-inspection operator console may evaluate a selected S-120 output for compatible local display and interface electronics. Confirm board requirements and segregate mains from signal wiring. Probe excitation, reference signals, tube handling and inspection accuracy are independently qualified functions.
S-120 Technical FAQs
Which exact output models and current ranges are listed?
S-120-12 lists 12V 0~10A; S-120-15 lists 15V 0~8A; S-120-18 lists 18V 0~6.7A; S-120-24 lists 24V 0~5A; S-120-36 lists 36V 0~3.3A; S-120-48 lists 48V 0~2.5A. These are separate single-output models, not simultaneous rails. Select one exact suffix for the connected board.
Does the 120W designation establish every continuous operating point?
The family designation and the printed current ranges are separate entries. Do not calculate a replacement continuous wattage from their endpoints or assume maximum output at every input and temperature. Confirm the ordered suffix’s continuous and startup duty. The printed zero lower bounds do not independently establish minimum-load or no-load acceptance.
Is the AC input automatically selected?
The input entry is 90~132VAC/180~264VAC by switch, with 254~370VDC and 47~63Hz also listed. This requires manual AC selection, not an automatic universal-input assumption. Confirm the actual switch setting and connection instructions before energizing, including any proposed DC-input use.
What does the DC-voltage adjustment range establish?
All listed versions have ±10% DC-voltage adjustment. Check the connected board’s voltage limits and the exact model’s accepted duty before adjusting. This entry does not establish regulated-current output, dimming, battery charging or arbitrary programmable operation.
What ripple and line/load stability apply to each suffix?
S-120-12: 100mVp-p, line stability ±0.3%, load stability ±0.3%; S-120-15: 100mVp-p, line stability ±0.3%, load stability ±0.3%; S-120-18: 100mVp-p, line stability ±0.2%, load stability ±0.2%; S-120-24: 100mVp-p, line stability ±0.2%, load stability ±0.2%; S-120-36: 100mVp-p, line stability ±0.2%, load stability ±0.2%; S-120-48: 100mVp-p, line stability ±0.2%, load stability ±0.2%. Line stability and load stability are separate parameters. These entries do not specify a ripple measurement bandwidth or cable method.
Which efficiency and cold-start entries apply to this family?
S-120-12: 81%; S-120-15: 82%; S-120-18: 84%; S-120-24: 84%; S-120-36: 84%; S-120-48: 84%. Cold-start current is 30A/115VAC and 60A/230VAC. These transients apply at their stated input voltages; they are not continuous input current. Efficiency measurement conditions beyond the printed entries need confirmation.
How does overload protection recover?
The overload entry is 105%~150%, cutting off output with automatic recovery. It is not a continuous overload allowance or a replacement for branch and cable protection. Evaluate the electronics’ restart behavior and repeated-fault response in the completed equipment.
Does overvoltage shutdown require re-powering?
The overvoltage entry is 115%~135%, shutting down output voltage and requiring re-powering to recover. This differs from automatic overload recovery. Downstream protection and safe equipment restart require their own verification.
Which setup, rise and hold-up times and test conditions are stated?
Setup, rise and hold-up are 200ms, 50ms and 20ms at 230VAC and full load. The stated input and full-load conditions apply to this timing entry. Full-load timing does not establish full-temperature full-load operation, an uninterrupted supply or the same response at all input voltages and loads.
What working temperature, dimensions and mass are listed?
The entries are -10°C~+50°C, 199×98×38mm and 0.6kg. Check the actual compartment temperature, mounting, terminal access and cooling arrangement. These entries do not provide an ingress rating, humidity limit or complete full-load derating curve.
What withstand and isolation-resistance entries are printed?
Withstand entries are I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute, without a printed AC/DC qualifier. Isolation resistance is I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ. These component test entries do not establish certification scope or finished-equipment approval.
What terminal order does the drawing show?
The drawing labels pins 1 and 2: AC input; pin 3: GND; pins 4 and 5: DC output-V; pins 6 and 7: DC output+V. Confirm the delivered terminal markings, connection instructions, conductor ratings and protective bonding before wiring. The AC labels do not establish DC-input terminal assignments. The duplicated signed output terminals do not establish independent rails, permitted strapping or conductor current allocation.
¿Cuáles son los mejores productos de fuentes de alimentación para su empresa?
Impulsa tu negocio con productos de suministro de energía de calidad WEHO.
Pregúntale a un experto