WEHO S-145 is a single-output power-supply family for equipment builders evaluating a compact local DC rail for interface and status electronics. S-145 has separate 5V, 12V, 18V, 24V, 36V and 48V output variants. The listed body dimensions are 199×98×38mm. AC input is 90~132VAC/180~264VAC by switch; the same input row also lists 254~370VDC and 47~63Hz. Its lower-profile body is useful to assess where a small instrument bay must also accommodate supported wiring and maintenance access. Match the exact suffix to the electronic load and request confirmation of the required version before ordering.

Si tiene alguna pregunta, no dude en contactarnos en Correo electrónico: [email protected]

Especificación S-145-5 S-145-12 S-145-18 S-145-24 S-145-36 S-145-48
Tensión de salida CC, corriente 5V 0 ~ 25A 12V 0 ~ 12A 18V 0 ~ 8A 24V 0 ~ 6A 36V 0 ~ 4A 48V 0 ~ 3A
Ola y ruido 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
Estabilidad del cable de entrada ±0,5% ±0,3% ±0,3% ± 0.2% ± 0.2% ± 0.2%
Estabilidad de carga ±0,5% ±0,3% ±0,3% ± 0.2% ± 0.2% ± 0.2%
Eficiencia 70% 80.5% 80.5% 83.5% 83.5% 83.5%
Rango ajustable para voltaje CC ±10% ±10% ±10% ±10% ±10% ±10%
Rango de voltaje de entrada 90 ~ 132VAC/180 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz
Corriente de impacto Cold start current 35A/115VAC 60A/230VAC
Protección contra sobrecarga 105% ~ 150% cut off the output, automatic recovery
Protección contra sobretensión 115% ~ 150% shut down O/P voltage, re-power on to recover
Configurar, levantarse, mantener el tiempo de actividad 100ms, 50ms, 20ms/230VAC at full load
Voltaje de soporte I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute
Resistencia de aislamiento I/P-O/P, I/P-FG, O/P-FG: 500 VCC/100 MΩ
Temperatura de trabajo -10°C ~ +50°C
Dimensión 199 × 98 × 38mm
Peso 0.7kg
Embalaje 43 × 32.5 × 24CM/30PCS/21kg

Why Choose S-145?

Choose the rail, not just the family name

S-145 has separate 5V, 12V, 18V, 24V, 36V and 48V output variants. This makes output selection an explicit part of an optical instrument or small operator-panel design rather than treating the suffixes as interchangeable.

Assess a compact instrument bay

The listed body dimensions are 199×98×38mm. The listed weight is 0.7kg. Use these body figures as an initial space check for a desktop label dispenser, then allow separately for terminals, conductor support, cooling and service access.

Plan the actual supply connection

AC input is 90~132VAC/180~264VAC by switch; the same input row also lists 254~370VDC and 47~63Hz. A cable-test bench therefore needs a correctly set AC input arrangement; the DC entry is a separate operating case to confirm before connection.

Distinguish the two fault responses

Overload protection is listed at 105%~150% with output cutoff and automatic recovery. Overvoltage protection is listed at 115%~150%; the output shuts down and requires re-powering to recover. The different restart behavior matters when a component counter must retain its state after a supply fault. Neither response establishes machine protective performance.

S-145 Features and Selection Details

Suffix-specific electronic-load matching

The output table lists S-145-5: 5V, 0~25A; S-145-12: 12V, 0~12A; S-145-18: 18V, 0~8A; S-145-24: 24V, 0~6A; S-145-36: 36V, 0~4A; S-145-48: 48V, 0~3A. The current ranges belong to separate output models. A zero lower bound is not evidence of no-load regulation or a shared power budget across variants.

Noise figures for an instrument interface

The wave-and-noise entries are S-145-5: 100mVp-p; S-145-12: 100mVp-p; S-145-18: 100mVp-p; S-145-24: 100mVp-p; S-145-36: 100mVp-p; S-145-48: 100mVp-p. Compare the selected column with the interface board specification; do not treat these entries as a calibrated sensor supply or assume an unstated measurement bandwidth.

Separate line and load behavior

The line/load-stability entries are S-145-5: line ±0.5%, load ±0.5%; S-145-12: line ±0.3%, load ±0.3%; S-145-18: line ±0.3%, load ±0.3%; S-145-24: line ±0.2%, load ±0.2%; S-145-36: line ±0.2%, load ±0.2%; S-145-48: line ±0.2%, load ±0.2%. The stability figures help define a board-level voltage budget, but do not establish precision measurement accuracy for an optical comparator or cable tester.

Adjustment with a bounded efficiency comparison

Each S-145 output column lists a ±10% DC-voltage adjustment range. The efficiency entries are S-145-5: 70%; S-145-12: 80.5%; S-145-18: 80.5%; S-145-24: 83.5%; S-145-36: 83.5%; S-145-48: 83.5%. The adjustment is for setting a compatible rail, not current regulation. Efficiency figures have no typical or full-load qualifier in this row and do not guarantee installed thermal performance.

Typical S-145 Service Conditions

Temperature planning for an optical profile comparator

An optical profile comparator may evaluate a selected S-145 variant for its compatible menu and status boards. The listed working-temperature range is -10°C~+50°C. Check actual bay temperature and ventilation without assigning the measuring optics or lamp to this rail; the range is not a full-load-throughout-range guarantee.

Input selection at a tabletop label dispenser

A tabletop label dispenser may assess S-145 for compatible count-display electronics inside a dry, protected compartment. AC input is 90~132VAC/180~264VAC by switch; the same input row also lists 254~370VDC and 47~63Hz. Verify the selector before energizing and keep adhesive contamination away from the electrical bay. The feed mechanism and its motor require separate power selection.

Cold starts at a cable continuity tester

A cable continuity tester may consider S-145 for compatible local interface electronics. Cold-start current is listed as 35A at 115VAC; 60A at 230VAC. Coordinate branch protection and repeated starts with the actual supply. Calibrated test excitation, leakage measurement and test accuracy are separate requirements.

Interruption handling in a component counting carousel

A component counting carousel may evaluate S-145 for compatible count-memory and user-interface boards. Setup, rise and hold-up times are 100ms, 50ms and 20ms, respectively, at 230VAC and full load. Validate count retention and reset behavior against the real cycle; these times do not provide an uninterruptible supply or qualify the carousel drive.

Potential S-145 Equipment Applications

Parcel dimensioning station

A parcel dimensioning station may evaluate an exact S-145 output variant for compatible local display and communication boards. Check rail voltage, ripple tolerance and startup demand. Optical sensing, dimensional calibration and conveyor drives remain separately specified; the supply is not evidence of measurement accuracy.

Library self-check kiosk

A library self-check kiosk may consider a selected S-145 suffix for compatible user-interface logic in its protected electronics bay. Confirm the controller rail and restart behavior. RFID readers, receipt printers and public-access electrical protection need separate qualification; this is not a proven kiosk installation.

Bench microfiltration monitor

A bench microfiltration monitor may assess S-145 for compatible local logging and status electronics, separated from liquid paths and cleaning exposure. Verify the load and real bay temperature. Pump power, fluid-pressure control and calibrated analytical sensing are outside this proposed electronic role.

Rotary pad-printing machine

A rotary pad-printing machine may evaluate an exact S-145 variant for compatible job-entry and local status boards. Keep ink and cleaning solvent outside the electrical compartment and check startup and thermal duty. Rotation, printing actuators and process-quality control need independent power and design.

S-145 Technical FAQs

Which output variants and current ranges are documented for S-145?

The output table lists S-145-5: 5V, 0~25A; S-145-12: 12V, 0~12A; S-145-18: 18V, 0~8A; S-145-24: 24V, 0~6A; S-145-36: 36V, 0~4A; S-145-48: 48V, 0~3A. The summary states 145W, while S-145-5 is listed at 5V with a 0~25A current range. These are separate output choices, not simultaneous rails. The current-range lower bound does not establish no-load regulation, and the summary is not a universal continuous rating.

Which input ranges and selection method are stated for S-145?

AC input is 90~132VAC/180~264VAC by switch; the same input row also lists 254~370VDC and 47~63Hz. Select the AC band before energizing; this is not automatic range switching. Confirm the separate DC operating case for the delivered version.

Which cold-start currents are listed for S-145, and under what inputs?

Cold-start current is listed as 35A at 115VAC; 60A at 230VAC. These are cold-start entries, not normal input current or output-load capability. Coordinate the instrument bay and its upstream protection with the actual installation.

How do the wave-and-noise entries vary across S-145 outputs?

The wave-and-noise entries are S-145-5: 100mVp-p; S-145-12: 100mVp-p; S-145-18: 100mVp-p; S-145-24: 100mVp-p; S-145-36: 100mVp-p; S-145-48: 100mVp-p. The same printed figure applies to every listed suffix, but no measurement bandwidth or fixture is stated. Sensitive test circuitry needs its own compatibility check.

Which line and load stability values belong to each S-145 suffix?

The line/load-stability entries are S-145-5: line ±0.5%, load ±0.5%; S-145-12: line ±0.3%, load ±0.3%; S-145-18: line ±0.3%, load ±0.3%; S-145-24: line ±0.2%, load ±0.2%; S-145-36: line ±0.2%, load ±0.2%; S-145-48: line ±0.2%, load ±0.2%. The lower-voltage columns have different entries from the higher-voltage columns. Do not treat a line-stability percentage as an adjustment range or a measurement-accuracy rating.

What do the DC adjustment and efficiency entries establish for S-145?

Each S-145 output column lists a ±10% DC-voltage adjustment range. The efficiency entries are S-145-5: 70%; S-145-12: 80.5%; S-145-18: 80.5%; S-145-24: 83.5%; S-145-36: 83.5%; S-145-48: 83.5%. The entries do not include a typical/full-load efficiency condition. Adjustment does not turn S-145 into a constant-current source or a battery charger.

How does the documented S-145 overload response recover?

Overload protection is listed at 105%~150% with output cutoff and automatic recovery. This is a fault response, not a normal constant-current operating range. Downstream count or interface electronics must handle the loss and return of power.

How does the documented S-145 overvoltage response recover?

Overvoltage protection is listed at 115%~150%; the output shuts down and requires re-powering to recover. Re-powering is different from the automatic recovery stated for overload. The surrounding machine must handle a stopped electronic rail independently.

What are the S-145 setup, rise and hold-up times and test condition?

Setup, rise and hold-up times are 100ms, 50ms and 20ms, respectively, at 230VAC and full load. The order is setup, rise, then hold-up. The stated input and full-load condition apply to this timing entry, not to all temperature and load combinations.

Which working temperature, body dimensions and weight are listed for S-145?

The listed working-temperature range is -10°C~+50°C. The listed body dimensions are 199×98×38mm. The listed weight is 0.7kg. Allow separately for wiring, airflow and service access. No derating curve or full-load-throughout-temperature guarantee is provided by the temperature row.

Which isolation and withstand test entries are stated for S-145?

The isolation-resistance row lists 500VDC/100MΩ for I/P-O/P, I/P-FG and O/P-FG. Withstand entries are I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute, without a printed AC/DC qualifier. These are component test entries, not an installation certification or permission to select bonding and insulation without a system assessment.

What does the S-145 terminal legend establish before wiring?

The 7-pin drawing legend identifies pins 1,2 AC input; pins 3 GND; pins 4,5 DC output-V; pins 6,7 DC output+V. The drawing legend is not proof of the delivered suffix wiring. Confirm terminal markings, polarity, protective bonding and branch protection before connection.

¿Cuáles son los mejores productos de fuentes de alimentación para su empresa?

Impulsa tu negocio con productos de suministro de energía de calidad WEHO.

Pregúntale a un experto
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.