| Especificación | S-150-5 | S-150-12 | S-150-15 | S-150-24 | S-150-36 | S-150-48 |
| Tensión de salida CC, corriente | 5V 0 ~ 30A | 12V 0 ~ 12.5A | 15V 0 ~ 10A | 24V 0 ~ 6.5A | 36V 0 ~ 4.17A | 48V 0 ~ 3.13A |
| Ola y ruido | 150mVp-p | 180mVp-p | 180mVp-p | 240mVp-p | 240mVp-p | 240mVp-p |
| Estabilidad del cable de entrada | ±0,5% | ±0,3% | ±0,3% | ± 0.2% | ± 0.2% | ± 0.2% |
| Estabilidad de carga | ±0.8% | ±0,3% | ±0,3% | ± 0.2% | ± 0.2% | ± 0.2% |
| Eficiencia | 78% | 82% | 84% | 85% | 86% | 87% |
| Rango ajustable para voltaje CC | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
| Rango de voltaje de entrada | 90 ~ 132VAC/180 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz | |||||
| Corriente de impacto | Corriente de arranque en frío 35A/230VAC | |||||
| Protección contra sobrecarga | 105% ~ 150% cut off the output, automatic recovery | |||||
| Protección contra sobretensión | 115% ~ 135% shut down O/P voltage, re-power on to recover | |||||
| Configurar, levantarse, mantener el tiempo de actividad | 100ms, 50ms, 20ms/230VAC at full load | |||||
| Voltaje de soporte | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||||
| Resistencia de aislamiento | I/P-O/P, I/P-FG, O/P-FG: 500 VCC/100 MΩ | |||||
| Temperatura de trabajo | -10°C ~ +50°C | |||||
| Dimensión | 199 × 110 × 50mm | |||||
| Peso | 0,85 kg | |||||
| Embalaje | 42 × 31.5 × 26CM/20PCS/17kg | |||||
Fuente de alimentación conmutada única normal serie S-150W
WEHO S-150 is a single-output power-supply family with six separate 5V, 12V, 15V, 24V, 36V and 48V variants. The 199×110×50mm format gives equipment builders a defined starting point for protected local electronics, with output-specific noise and regulation figures for selection. AC input is 90~132VAC/180~264VAC by switch; 254~370VDC and 47~63Hz are also listed. Match an exact suffix to the electronic load, then verify continuous duty, startup, wiring and enclosure temperature. The 150W designation is not a substitute for that assessment. Discuss the required output and equipment duty before ordering.
Si tiene alguna pregunta, no dude en contactarnos en Correo electrónico: [email protected]
- Descripción
Why Choose S-150?
Compare the regulation of the actual output
The 24V, 36V and 48V variants list ±0.2% line stability and ±0.2% load stability; the 5V model lists ±0.5% and ±0.8% respectively. These distinctions help a builder screen compatible display, logic and interface boards without treating the best number as a family-wide promise. Verify voltage at the real load and its return connection.
Keep input selection visible in the build specification
The stated 90~132VAC/180~264VAC input is selected by switch. Include the correct line setting in the equipment assembly and service instructions rather than describing the supply as automatic universal input. The listed 254~370VDC entry does not establish DC connection details or approval for every DC system.
Use conditioned timing for a reset decision
Setup, rise and hold-up are 100ms, 50ms and 20ms at 230VAC and full load. These entries give an electronics designer a specific condition to compare with boot and reset requirements. They do not establish uninterrupted service, stored-data retention or identical timing under every input and load.
Check a compact outline without assuming a drop-in fit
The 199×110×50mm outline and seven-pin legend make mounting and service access concrete review items. Pins 1 and 2 are AC input, pin 3 is GND, pins 4 and 5 are DC output-V, and pins 6 and 7 are DC output+V. Confirm the delivered unit and exact mounting drawing; a similar case does not establish interchangeable wiring.
S-150 Features
Six ordered single-output models
S-150-5 lists 5V 0~30A; S-150-12 lists 12V 0~12.5A; S-150-15 lists 15V 0~10A; S-150-24 lists 24V 0~6.5A; S-150-36 lists 36V 0~4.17A; S-150-48 lists 48V 0~3.13A. These are alternative models, not six rails on one unit. Confirm usable continuous duty for the selected suffix and equipment conditions.
Output-dependent ripple with voltage adjustment
Ripple is 150mVp-p for 5V, 180mVp-p for 12V and 15V, and 240mVp-p for 24V, 36V and 48V. Each column lists ±10% DC-voltage adjustment. Use the exact output’s noise and load-voltage limits; the adjustment entry does not describe constant-current regulation, dimming or battery charging.
A specific cold-start condition
Cold-start current is 35A/230VAC. No 115VAC cold-start value accompanies that entry. Assess upstream switching and startup coordination at this stated input condition. Inrush is not continuous input current.
Distinct protection and restart responses
Overload is listed as 105%~150%, cutting off output with automatic recovery. Overvoltage is 115%~135%, shutting down output and requiring re-powering. Evaluate the connected electronics’ behavior after either event; neither percentage range permits continuous fault operation or replaces equipment protection.
Typical Service Conditions
Enclose electronics at a rotary dial assembly machine
A guarded rotary dial assembly machine may evaluate an S-150 variant for compatible sequencer and operator-interface electronics. Keep metal fragments out of the protected electrical compartment and assess its real temperature during repeated indexing. The index motor, pneumatic actuation and machine safeguarding require separate power and engineering.
Control dust at a PCB depaneling router
A PCB depaneling router needs a clean electrical bay separated from routing dust and extraction airflow. An exact S-150 suffix could serve compatible local logic and status boards after startup and thermal checks. The spindle, axis drives and dust extractor are not loads covered by this electronic-supply concept.
Segregate sensitive wiring at a sheet-metal laser marker
A sheet-metal laser marker should separate mains and high-energy equipment wiring from its local user-interface and communication electronics. Evaluate a selected S-150 only for those compatible boards, including their noise tolerance. Laser emission, scanning hardware and protective interlocks require independently qualified systems.
Assess heat at a textile sample cutter
A textile sample cutter may consider an S-150 output for compatible control-interface electronics in a protected compartment. Check fibre accumulation, local temperature and board reset behavior through the real operating cycle. Cutting drives, blade actuation and operator protection remain outside this proposed DC role.
Potential S-150 Applications
Industrial sewing-head workstation
An industrial sewing-head workstation may evaluate a selected S-150 output for compatible stitch-program interface and status electronics. Confirm the exact board voltage, boot demand and enclosure conditions. The sewing motor, needle mechanism and machine safety functions need separate qualified power and control design.
Tray-stack elevator
A tray-stack elevator may consider an accepted S-150 variant for compatible local sequencer and display boards. Check electronic demand during boot and communication recovery, with protected cable routing. The lift motor, holding brake, position sensing and anti-fall protection are separately engineered functions.
Wire-harness pin-insertion cell
A wire-harness pin-insertion cell can assess an exact S-150 suffix for compatible controller-interface and indication electronics. Verify actual voltage and noise at those boards. Insertion actuators, tool force control and connector-quality verification are not established by selecting the supply.
Ink-circulation print-carriage rig
An ink-circulation print-carriage rig may evaluate a qualified S-150 output for compatible local interface electronics in a dry, segregated electrical bay. Confirm startup, temperature and fluid protection. Pumps, carriage drives, printhead excitation and print-quality performance require their own electrical qualification.
S-150 Technical FAQs
Which exact output models and current ranges are listed?
S-150-5 lists 5V 0~30A; S-150-12 lists 12V 0~12.5A; S-150-15 lists 15V 0~10A; S-150-24 lists 24V 0~6.5A; S-150-36 lists 36V 0~4.17A; S-150-48 lists 48V 0~3.13A. These are alternative single-output models, not six simultaneous rails. The printed zero lower bounds do not independently establish no-load regulation.
Does the family designation establish every continuous operating point?
The family is designated 150W. Do not calculate a replacement continuous wattage from voltage multiplied by a printed current-range endpoint. The current ranges do not by themselves establish minimum load, universal no-load operation or full-load output at every input and temperature. Confirm actual continuous and startup demand for the exact electronic load.
Which input bands and selection information are specified?
The input entry is 90~132VAC/180~264VAC by switch, with 254~370VDC and 47~63Hz also listed. Select the AC band manually and verify the correct AC setting. The DC range is not a wiring instruction or proof of compatibility with every DC source; confirm the exact delivered unit’s connection requirements.
What does the voltage-adjustment entry establish?
Each of the six models lists ±10% DC-voltage adjustment. Match any setting to the connected board’s voltage limits and the exact model’s verified duty. This entry does not establish constant-current regulation, programmable operation, dimming, battery charging or permission to exceed the equipment’s accepted operating envelope.
Which ripple and line/load stability belong to each output?
S-150-5: 150mVp-p ripple, ±0.5% line stability, ±0.8% load stability; S-150-12: 180mVp-p ripple, ±0.3% line stability, ±0.3% load stability; S-150-15: 180mVp-p ripple, ±0.3% line stability, ±0.3% load stability; S-150-24: 240mVp-p ripple, ±0.2% line stability, ±0.2% load stability; S-150-36: 240mVp-p ripple, ±0.2% line stability, ±0.2% load stability; S-150-48: 240mVp-p ripple, ±0.2% line stability, ±0.2% load stability. Line stability and load stability are separate parameters. These entries do not specify a ripple-measurement bandwidth or complete load-side wiring method.
Which efficiency and cold-start values belong to this family?
Efficiencies in S-150-5, S-150-12, S-150-15, S-150-24, S-150-36, S-150-48 order are 78%, 82%, 84%, 85%, 86%, 87%. Cold-start current is 35A/230VAC. No 115VAC cold-start value is printed in this entry. The inrush values are transient entries, not continuous input current or protective-device selections.
What overload range and recovery behavior are printed?
The overload entry prints 105%~150%, cutting off the output with automatic recovery. This is not a sustained overload allowance. Check the connected electronics’ response to repeated power loss and recovery and coordinate equipment protection separately.
How does overvoltage shutdown recover?
The overvoltage entry is 115%~135%, shutting down the output voltage and requiring re-powering to recover. This differs from automatic overload recovery. Evaluate downstream protection and a safe equipment restart independently of this supply response.
Which setup, rise and hold-up times and conditions are given?
Setup, rise and hold-up are 100ms, 50ms and 20ms at 230VAC and full load. The stated input and full-load conditions apply to this timing entry. Timing at full load is not permission for full load across the temperature range, nor a guarantee of the same response at every input and load.
What temperature, dimensions and mass are listed?
The listed working temperature is -10°C~+50°C, dimensions are 199×110×50mm and mass is 0.85kg. Check actual local temperature, mounting, terminal access and service clearance. These entries do not provide an ingress rating, humidity specification or complete full-load derating curve.
What withstand and isolation-resistance entries are specified?
The withstand row lists I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute, without an AC/DC qualifier. Isolation resistance is listed as 500VDC/100MΩ for I/P-O/P, I/P-FG and O/P-FG. These are test entries, not an undocumented certification, inter-output-isolation claim or finished-equipment safety approval.
What terminal assignment is shown, and does it establish variant wiring?
The seven-pin legend labels pins 1 and 2 as AC input, pin 3 as GND, pins 4 and 5 as DC output-V, and pins 6 and 7 as DC output+V. Treat this as the printed generic legend, not suffix-specific installation approval or permission to strap terminals. Confirm the delivered markings, conductor sizing, bonding, branch protection and connection instructions, including any proposed DC-input use. Use the delivered S-150 markings and its approved connection instructions.
¿Cuáles son los mejores productos de fuentes de alimentación para su empresa?
Impulsa tu negocio con productos de suministro de energía de calidad WEHO.
Pregúntale a un experto