| Especificación | S-2000-24 | S-2000-27 | S-2000-36 | S-2000-48 |
| Tensión de salida CC, corriente | 24V 0 ~ 83A | 27V 0 ~ 74A | 36V 0 ~ 55A | 48V 0 ~ 41A |
| Ola y ruido | 120mVp-p | 200mVp-p | 200mVp-p | 240mVp-p |
| Estabilidad del cable de entrada | +0.5% | +0.5% | +0.5% | +0.5% |
| Estabilidad de carga | +0.5% | +0.5% | +0.5% | +0.5% |
| Eficiencia | 80% | 85% | 86% | 87% |
| Rango ajustable para voltaje CC | ±10% | ±10% | ±10% | ±10% |
| Rango de voltaje de entrada | 200 ~ 264VAC | |||
| Corriente de impacto | Corriente de arranque en frío 45A/230VAC | |||
| Protección contra sobrecarga | 105% ~ 135% cut off the output, automatic recovery | |||
| Protección contra sobretensión | Not specified in this datasheet (overvoltage threshold and short-circuit recovery mode are not stated). | |||
| Configurar, levantarse, mantener el tiempo de actividad | 2000ms, 50ms, 20ms/230VAC at full load | |||
| Voltaje de soporte | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||
| Resistencia de aislamiento | I/P-O/P, I/P-FG, O/P-FG: 500 VCC/100 MΩ | |||
| Temperatura de trabajo | -10°C ~ +50°C | |||
| Dimensión | 291 × 132 × 136mm | |||
| Peso | 5.3kg | |||
| Embalaje | 38 × 37.5 × 21CM/2PCS/11kg | |||
Serie S-2000W fuente de alimentación de conmutación simple normal
WEHO S-2000 is a 2000W-class enclosed single-output family for engineered DC equipment and load-test assemblies. Its separate models cover 24V 0~83A, 27V 0~74A, 36V 0~55A and 48V 0~41A, with a listed 200~264VAC input. Select by the exact output and verified load profile, then check high-current terminations and thermal duty; the family wattage label alone does not guarantee continuous output under every installation condition.
Si tiene alguna pregunta, no dude en contactarnos en Correo electrónico: [email protected]
- Descripción
Why choose S-2000
A distinct 27V option
S-2000-27 lists 27V 0~74A alongside 24V, 36V and 48V alternatives. This can matter for a compatible equipment rail, but 27V is a separate model choice, not evidence that another output should be adjusted to replace it.
An explicit high-line AC range
The summary and input row both state 200~264VAC. Use this to screen incoming equipment power before detailed design; no low-line switching band, DC-input range or frequency value is stated for S-2000.
A defined mechanical starting point
The table lists 291×132×136mm and 5.3kg. Check the actual orientation and projecting terminals against the drawing before allocating cabinet space; the drawing does not separately dimension the table’s 136mm extent.
Appropriate current for substantial DC fixtures
A multi-channel DC product burn-in rack or distribution test cell may warrant the listed current class. A low-power indicator board alone would need a separate sizing justification. Base the choice on measured load demand, safe wiring and validated continuous duty rather than the 2000W headline.
S-2000 features
Output-specific noise figures
Ripple/noise is listed as 120mVp-p for S-2000-24, 200mVp-p for S-2000-27 and S-2000-36, and 240mVp-p for S-2000-48. Measurement bandwidth and probe arrangement are not specified.
Literal stability and efficiency entries
The line- and load-stability rows each print +0.5%, not ±0.5%. Efficiencies are 80%, 85%, 86% and 87% in 24V, 27V, 36V and 48V order. Confirm the intended stability limits and efficiency test conditions for a binding equipment specification.
Adjustment within the selected output
The visible table shows ±10% DC-voltage adjustment. Check the permitted voltage at every connected device and the allowable current at the chosen setting; no programmable control, current-sharing or cross-model substitution is established.
Documented overload action
At 105%~135% overload the stated action is output cut-off with automatic recovery. Coordinate downstream protection and restart behaviour; do not use this entry as a short-circuit endurance or overvoltage specification.
S-2000 service conditions
High-line fan-module endurance wall
A guarded industrial DC fan-module endurance wall must receive power within 200~264VAC. The listed 45A cold-start current is tied to 230VAC. Confirm the actual supply frequency and input-terminal functions before choosing the branch circuit. The proposed DC duty is electrically compatible DC fan modules under test, with actual startup and fault demand separately qualified. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.
Network-device batch loading
An industrial Ethernet-switch burn-in conveyor requires the exact output model, current profile and conductor temperature assessment. Printed 0~83A, 0~74A, 0~55A or 0~41A ranges do not establish a test duration, minimum-load requirement or continuous equipment rating. The proposed DC duty is compatible DC-input network devices in a measured batch; no PoE-output or data-performance function is assigned to the supply. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.
Printer-test-line cabinet ventilation
A ticket-printer production test line needs space around the complete enclosure and both fan areas. The working-temperature row is −10°C~+50°C; the sheet gives no airflow specification or derating curve to establish full-load operation across that range. The proposed DC duty is compatible fixed-voltage DC inputs of printers under test, not the test-line transport drive. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.
Relay-coil test restart coordination
An interlocked relay-coil endurance rack should allow setup 2000ms, rise 50ms and hold-up 20ms, specified at 230VAC and full load. Assess overload recovery and fixture sequencing separately from these normal timing values. The proposed DC duty is selected compatible DC coil test branches, with independently designed switching and transient suppression. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.
S-2000 application considerations
Industrial panel-PC batch tests
A guarded panel-PC batch test wall is a potential use for a compatible S-2000-24 rail. Establish aggregate DC demand, input tolerance, startup sequence, wiring drop and continuous thermal duty before selection. The supply does not establish computing, touch-screen or communications performance; the test equipment mains remain separate. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.
RF module acceptance equipment
An RF amplifier-module acceptance cell may assess S-2000-27 only for modules whose specified DC input accepts the selected 27V rail. Validate current transients, supply-noise tolerance, dissipation and duty. RF test loads, shielding, instrumentation and measurement performance require independent design; no RF compatibility or calibrated-source claim follows from the supply family. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.
Solenoid-valve production tests
A guarded solenoid-valve production carousel may evaluate a matching 24V or 48V S-2000 output for documented DC coil-test demand. Specify external switching, transient suppression, branch protection and safe access. Compressed-air services and the carousel drive are separately engineered; the supply does not establish valve response, fault endurance or machine-safety performance. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.
Signalling-panel indicator checks
A control-panel indicator test line may assess S-2000-24 for assemblies whose specified input accepts 24V DC. Establish aggregate branch demand, device voltage limits, switching transients and thermal duty. The supply does not provide lamp sequencing, alarm logic or protective functions; independent controls and branch protection remain necessary. This is a proposed use only, subject to exact-variant, load, wiring, protection and thermal qualification; it is not a customer installation.
S-2000 technical FAQs
Which exact output models are listed?
S-2000-24: 24V 0~83A; S-2000-27: 27V 0~74A; S-2000-36: 36V 0~55A; S-2000-48: 48V 0~41A. These are separate model choices, not simultaneous outputs. The lower bound of each printed range is zero; that alone does not establish minimum-load behaviour or a complete continuous-duty specification.
Does the 2000W class label guarantee continuous power in my enclosure?
No. The summary states 2000W for the family, while each output column has its own printed current range. The sheet does not define the continuous-load relationship to ambient temperature, airflow, mounting or adjustment. The printed ranges do not establish a continuous-power rating calculated from voltage times current.
What input range and selection method are documented?
The stated input is 200~264VAC. No input frequency, DC range, low-line switching band or three-phase connection is specified. Obtain the exact unit’s input connection details before installation.
What cold-start current must the upstream design consider?
The listed cold-start current is 45A at 230VAC. It is not a normal running-current figure and no second input condition is supplied. Coordinate the actual circuit and starting sequence rather than extrapolating this value to every input voltage.
What are the setup, rise and hold-up times?
Setup is 2000ms, rise is 50ms and hold-up is 20ms at 230VAC and full load, in that order. These values do not establish the response at another input voltage, a different load or during overload recovery.
What ripple/noise values should be used for selection?
S-2000-24: 120mVp-p; S-2000-27: 200mVp-p; S-2000-36: 200mVp-p; S-2000-48: 240mVp-p. Measurement bandwidth, probing and load conditions are not given. Validate compatibility with sensitive loads using the agreed test method.
How are stability and efficiency specified?
The line-stability and load-stability rows each print +0.5% for all four models. S-2000-24: 80%; S-2000-27: 85%; S-2000-36: 86%; S-2000-48: 87%. The one-sided +0.5% notation is shown; a symmetric tolerance is not stated. Efficiency measurement conditions are not stated; these entries do not prove system-level heat rejection.
How much voltage adjustment is shown?
The visible table shows ±10% DC-voltage adjustment for each selected model. Check device voltage tolerance and permitted current at the chosen setting. Adjustment does not establish a programmable control interface, constant-power operation or interchangeability with another model.
What overload behaviour is stated?
The threshold is 105%~135%, with output cut-off and automatic recovery. No permissible fault duration, recovery waveform or additional short-circuit/overvoltage action is stated. Engineer external protection and safe restart independently.
What do the temperature and insulation entries establish?
Working temperature is listed as −10°C~+50°C without a derating curve or airflow requirement. Withstand values are 1.5kV input-to-output, 1.5kV input-to-frame and 0.5kV output-to-frame for one minute; AC/DC waveform is not specified. Isolation resistance is listed as 100MΩ at 500VDC for those pairs. These tests do not authorize a common-ground or output-strapping arrangement.
What mechanical and shipping information is available?
The table lists 291×132×136mm, 5.3kg and packing 38×37.5×21CM/2PCS/11kg. The drawing shows a 291mm chassis span, 132mm depicted face/span and 30mm post projection, but does not separately dimension the table’s 136mm extent. Verify mounting reference points, actual orientation, terminal clearances and service space before approving fit.
Can I wire the equipment from the outline drawing alone?
The input drawing has five screw symbols, with only the middle three numbered 1, 2 and 3; it provides no L/N/FG function legend. The output end shows POS(+)/+V, NEG(−)/−V and LED with additional contact symbols. Confirm the actual input functions, output-contact relationship, bonding, conductor sizes, torque and branch protection; do not infer strapping from the drawing.