| مشخصات | S-1500-12 | S-1500-24 | S-1500-36 | S-1500-48 |
| ولتاژ خروجی DC، جریان | 12V 0 ~ 125A | 24V 0 ~ 63A | 36V 0 ~ 42A | 48V 0 ~ 31A |
| موج و نویز | 150mVp-p | 180mVp-p | 180mVp-p | 240mVp-p |
| پایداری سیم ورودی | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| پایداری بار | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| کارایی | 80% | 85% | 85% | 87% |
| محدوده قابل تنظیم برای ولتاژ DC | ± 10% | ± 10% | ± 10% | ± 10% |
| محدوده ولتاژ ورودی | 100 ~ 132VAC/200 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz | |||
| جریان ضربه | Cold start current 45A/230VAC | |||
| حفاظت اضافه بار | 105% ~ 135% cut off the output, automatic recovery | |||
| Other protection | Not specified in this datasheet (overvoltage threshold and short-circuit recovery mode are not stated). | |||
| راه اندازی، بالا آمدن، زمان نگه داشتن | 2000ms, 50ms, 20ms/230VAC at full load | |||
| مقاومت در برابر ولتاژ | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||
| مقاومت در برابر انزوا | I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ | |||
| دمای کاری | -10 درجه سانتیگراد ~ 50+ درجه سانتیگراد | |||
| بعد | 291 × 132 × 68mm | |||
| وزن | 2.65kg | |||
| بسته بندی | 37.5 × 31 × 25.5CM/6PCS/16kg | |||
S-1500W series normal single switching power supply
WEHO S-1500 is a single-output enclosed power-supply family in the 1500W class, with separate 12V, 24V, 36V and 48V models. It suits engineered high-current DC test fixtures and equipment subassemblies where the exact output, wiring and thermal duty are checked together. Its 100~132VAC/200~264VAC input uses a switch; the table also lists 254~370VDC. These are selection data, not permission to interchange input connections or treat every output as an unconditional 1500W continuous source.
اگر سوالی دارید، لطفا با ما در تماس باشید ایمیل: [email protected]
- توضیحات
Why choose S-1500
Match the fixture voltage first
Choose among S-1500-12 at 12V 0~125A, S-1500-24 at 24V 0~63A, S-1500-36 at 36V 0~42A and S-1500-48 at 48V 0~31A. These are separate output choices, not four simultaneous channels or one continuously variable 12–48V supply.
Plan the incoming supply deliberately
The two AC bands are 100~132VAC and 200~264VAC, selected by switch; frequency is listed as 47~63Hz. The separate 254~370VDC entry needs confirmed input polarity and connections. This is a useful fit check for equipment builders, not automatic universal-input operation.
Evaluate a low-profile chassis
The listed 291×132×68mm body and 2.65kg weight help assess a dedicated equipment compartment. Include the output-post projection, insulated terminations, mounting access and ventilation space rather than designing a cavity from the three body dimensions alone.
Use capacity where the DC load warrants it
A multi-position lighting-fixture tester or high-current connector station can justify this power class when the actual DC demand is documented. A small status board alone does not justify the sizing; confirm duty cycle, ambient temperature, conductor losses and a suitable continuous-load allowance before ordering.
S-1500 features
Four specific output columns
The four columns list ripple/noise as 150mVp-p at 12V, 180mVp-p at 24V and 36V, and 240mVp-p at 48V. Treat the figures as model-specific and confirm the measurement method for noise-sensitive equipment.
Published regulation and efficiency data
Line and load stability are each shown as ±0.5% for all four outputs. Listed efficiencies are 80%, 85%, 85% and 87% in 12V, 24V, 36V and 48V order; input, load and ambient test conditions are not supplied.
Output adjustment with limits
The table shows ±10% DC-voltage adjustment for each output. Set the required rail against the load specification and recheck allowable current and heating; adjustment is not a programmable sweep function or evidence of unchanged power at every setting.
Overload shutdown and recovery
The stated overload threshold is 105%~135%, with output cut-off and automatic recovery. Provide coordinated branch protection and a safe restart strategy; the entry does not establish fault endurance or additional protection modes.
S-1500 service conditions
Fan-module switch-on test bay
For a guarded industrial DC cooling-fan inspection conveyor, check the actual input against the switched AC bands before connection. The listed cold-start current is 45A at 230VAC; coordinate the upstream circuit for the station, not just its running load. The proposed DC duty is a batch of electrically compatible DC fan modules under test, not the conveyor drive or facility ventilation. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.
High-current production fixture
In a connector-contact endurance stand, choose the exact 12V, 24V, 36V or 48V output before sizing conductors and fixtures. The printed current ranges do not establish minimum-load requirements, contact temperature rise or continuous duty for a complete test sequence.
Ventilated equipment compartment
A lighting-module inspection cabinet must accommodate the 291×132×68mm body, projecting posts and service clearances. Working temperature is listed as −10°C~+50°C, but there is no derating curve or airflow requirement to prove full-load operation at either endpoint.
Sequenced display-module testing
For an industrial display-module soak-test carousel, account for setup 2000ms, rise 50ms and hold-up 20ms at 230VAC and full load. Verify the actual fixture restart sequence and load response instead of extending those timing figures to other input or load conditions. The proposed DC duty is compatible display-module electronic inputs in a documented aggregate batch, not the carousel motor or environmental-conditioning equipment. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.
S-1500 application considerations
DC load-development rack
A full-height electronic-load characterization rack is a potential use when one selected S-1500 output supplies the load under test. Validate transient demand, cable drop, load-bank dissipation and the allowed thermal duty; the supply is not a precision programmable source by implication.
LED-module production inspection
A guarded luminaire-panel inspection tunnel can use a compatible fixed-voltage DC rail for a documented batch of modules. Select the matching output and total current, and verify each module interface; no built-in dimming or constant-current LED-driver function is stated.
Connector and harness qualification
A floor-standing harness-contact test cell may use the chosen DC output for a controlled, measured load circuit. Fixture contacts, switching elements, branch protection and measurement isolation require their own engineering; the machine mains and motion drives are separate.
Power-distribution assembly checks
A cabinet-scale DC distribution-assembly tester may need this current class for a defined set of output branches. Confirm the exact voltage, branch loading and protection coordination without assuming permitted parallel operation, common grounding or whole-factory power capability.
S-1500 technical FAQs
Which exact output models are listed?
S-1500-12: 12V 0~125A; S-1500-24: 24V 0~63A; S-1500-36: 36V 0~42A; S-1500-48: 48V 0~31A. These are separate model choices, not simultaneous outputs. The lower bound of each printed range is zero; that alone does not establish minimum-load behaviour or a complete continuous-duty specification.
Does the 1500W class label guarantee continuous power in my enclosure?
No. The summary states 1500W for the family, while each output column has its own printed current range. The sheet does not define the continuous-load relationship to ambient temperature, airflow, mounting or adjustment. The printed ranges do not establish a continuous-power rating calculated from voltage times current.
What input range and selection method are documented?
The AC ranges are 100~132VAC/200~264VAC by switch, with 47~63Hz printed in the input row. The table separately lists 254~370VDC. Confirm the actual selector procedure, input connections and DC polarity before use; do not assume automatic input selection.
What cold-start current must the upstream design consider?
The listed cold-start current is 45A at 230VAC. It is not a normal running-current figure and no second input condition is supplied. Coordinate the actual circuit and starting sequence rather than extrapolating this value to every input voltage.
What are the setup, rise and hold-up times?
Setup is 2000ms, rise is 50ms and hold-up is 20ms at 230VAC and full load, in that order. These values do not establish the response at another input voltage, a different load or during overload recovery.
What ripple/noise values should be used for selection?
S-1500-12: 150mVp-p; S-1500-24: 180mVp-p; S-1500-36: 180mVp-p; S-1500-48: 240mVp-p. Measurement bandwidth, probing and load conditions are not given. Validate compatibility with sensitive loads using the agreed test method.
How are stability and efficiency specified?
The line-stability and load-stability rows each print ±0.5% for all four models. S-1500-12: 80%; S-1500-24: 85%; S-1500-36: 85%; S-1500-48: 87%. Efficiency measurement conditions are not stated; these entries do not prove system-level heat rejection.
How much voltage adjustment is shown?
The visible table shows ±10% DC-voltage adjustment for each selected model. Check device voltage tolerance and permitted current at the chosen setting. Adjustment does not establish a programmable control interface, constant-power operation or interchangeability with another model.
What overload behaviour is stated?
The threshold is 105%~135%, with output cut-off and automatic recovery. No permissible fault duration, recovery waveform or additional short-circuit/overvoltage action is stated. Engineer external protection and safe restart independently.
What do the temperature and insulation entries establish?
Working temperature is listed as −10°C~+50°C without a derating curve or airflow requirement. Withstand values are 1.5kV input-to-output, 1.5kV input-to-frame and 0.5kV output-to-frame for one minute; AC/DC waveform is not specified. Isolation resistance is listed as 100MΩ at 500VDC for those pairs. These tests do not authorize a common-ground or output-strapping arrangement.
What mechanical and shipping information is available?
The table lists 291×132×68mm, 2.65kg and packing 37.5×31×25.5CM/6PCS/16kg. The drawing shows 291.0, 132.0 and 68.0mm body spans and a 30.0mm output-post projection. Verify mounting reference points, actual orientation, terminal clearances and service space before approving fit.
Can I wire the equipment from the outline drawing alone?
The drawing labels FG, N and L beside an AC INPUT block, and POS(+)/+V, NEG(−)/−V, LED and V-ADJ on the output end. It does not supply a selector-position procedure or DC-input connection diagram. Confirm the actual terminal assignments, bonding, conductor sizes, torque and branch protection for the exact unit.