| Modèle | LPV-60-5E | LPV-60-12E | LPV-60-15E | LPV-60-24E | LPV-60-36E | LPV-60-48E | |
| Sortir | Tension CC | 5V | 12V | 15V | 24V | 36V | 48V |
| Courant nominal | 8a | 5A | 4A | 2,5A | 1.67A | 1.25A | |
| Plage actuelle | 0 ~ 8A | 0 ~ 5A | 0 ~ 4A | 0 ~ 2.5A | 0 ~ 1.67A | 0 ~ 1.25A | |
| Puissance nominale | 40W | 60W | 60W | 60W | 60W | 60W | |
| Ondulation et bruit (max.) | 80 mVcrête à crête | 120 mVcrête à crête | 120 mVcrête à crête | 150 mVcrête à crête | 150 mVcrête à crête | 150 mVcrête à crête | |
| Tolérance de tension | ±8.0% | ±5.0% | |||||
| Régulation de ligne | ±1,0% | ||||||
| Régulation de charge | ±6.0% | ±2,0% | |||||
| Configuration, temps de montée | 500ms, 20ms/230VAC; 500ms, 20ms/115VAC at full load(for 5-36V); 500ms, 30ms/230VAC; 500ms, 30ms/115VAC at full load (for 48V) | ||||||
| Hold UP Time (Typ.) | 50ms/230VAC 16ms/115VAC at full load | ||||||
| Saisir | Plage de tension | 90 ~ 264VAC 127 ~ 370VDC | |||||
| Gamme de fréquences | 47 ~ 63Hz | ||||||
| Efficacité (Typ.) | 78% | 83% | 83% | 86% | 86% | 86% | |
| AC Current (Typ.) | 1.2A/115VAC 1A/230VAC | ||||||
| Inrush Current (Typ.) | Cold Start 60A(twidth=525μs measured at 50% Ipeak) at 230VAC | ||||||
| MAX. No. of PSUs on 16A | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | ||||||
| Circuit Breaker | |||||||
| LEAKAGE CURRENT | 0.25mA / 240VAC | ||||||
| Protection | Surcharge | 110 ~ 150% rated output power | |||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
| Surtension | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | |
| Type de protection : arrêtez la tension o/p, remettez sous tension pour récupérer | |||||||
| Environnement | Température de travail | -30 ~ +70℃(Refer to “Derating Curve”) | |||||
| Humidité de travail | 20 ~ 90%RH non-condensing | ||||||
| Température de stockage, humidité | -40 ~ +80℃, 10 ~ 95%RH | ||||||
| Coefficient de température | ±0.03%/℃ (0 ~ 50℃) | ||||||
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along the X, Y, and Z axes | ||||||
| Safety & EMC | Normes de sécurité | IP67 approved; design refer to EN60950-1 | |||||
| Tension de tenue | I/P-O/P: 1,5 KVAC | ||||||
| Résistance d'isolement | I/P-O/P: >100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
| EMC Emission | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 | ||||||
| EMC Immunity | Compliance to EN55024, light industry level, criteria A | ||||||
| OTHERS | MTBF | 732Khrs min. MIL-HDBK-217F (25℃) | |||||
| Dimension | 162.5*42.5*32mm (L*W*H) | ||||||
| Emballage | 0.4Kg; 32pcs/13.8Kg/0.56CUFT | ||||||
Pilote LED en plastique étanche IP67, AC 110v/220v à sortie DC constante, alimentation 60W
Discontinued series - historical reference only. Production of the LPV and LPVE series has stopped. This page and its technical documents are retained for historical reference.
Ask our team to review your application and help select an XLG or HLG model. Suitability must be confirmed for your specific requirements; no automatic or universal replacement is implied.
LPV-60E power supply series is a fantastic AC-to-DC converter for delivering constant voltage in wet and dusty environments.
It comes from LPV Series Plastic Waterproof Power Supply Series which operates off-line voltage (90-264VAC) and delivers constant voltages from 5-48VDC depending on your selection.The 20 to 60 Watt models qualify as Class 2 power units offered in a slim, butter stick design.Si vous avez des questions, n'hésitez pas à nous contacter au E-mail: [email protected]
- Description
The product has perfect protection function and 5G shock resistance.
Nos produits ont une longue durée de vie, sont très fiables et très efficaces.
This product is ideal for a wide variety of LED lighting and equipment.
This product has a full range of input voltage 85-264VAC.
The product adopts a fully isolated plastic shell.
Need help selecting an XLG or HLG model?
Ask our team to review your application and discuss XLG or HLG options. Model suitability requires individual confirmation.
Demandez à un expert