Verify the input
Check 300–450 V AC at 47–63 Hz / 420–635 V DC at the installation point.
380 VAC input version of the LRS-60 platform (300–450 V AC, 47–63 Hz / 420–635 V DC). Choose the DC output voltage that matches your load. Output versions are adjustable ±10%.
| Parameter | LRH-60-5 | LRH-60-12 | LRH-60-15 | LRH-60-24 | LRH-60-48 |
|---|---|---|---|---|---|
| DC output voltage and current | 5 V · 0–12 A | 12 V · 0–5 A | 15 V · 0–4 A | 24 V · 0–2.5 A | 48 V · 0–1.3 A |
| इनपुट वोल्टेज रेंज | 300–450 V AC, 47–63 Hz / 420–635 V DC | ||||
| DIMENSIONS | 99 × 82 × 30 mm | ||||
| क्षमता | 86% | 86% | 88% | 88% | 90% |
| कार्य तापमान | −20 to +70 °C; full-load operation across this range is not specified. | ||||
| Ripple & noise | 120 mVp-p | 120 mVp-p | 120 mVp-p | 150 mVp-p | 200 mVp-p |
| रेखा विनियमन | ±0.5% | ||||
| लोड विनियमन | ±0.5% | ||||
| आउटपुट वोल्टेज समायोजन | ±10% | ||||
| Inrush current | Consult WEHO for 380 V AC test report | ||||
| अधिभार संरक्षण | 110–150%: output cuts off and recovers automatically. | ||||
| अन्य सुरक्षा | Overcurrent and short-circuit protection. | ||||
| Timing (setup / rise / hold-up) | Consult WEHO for 380 V AC test report | ||||
| वोल्टेज का सामना करें | Input–output 1.5 kV; input–frame 1.5 kV; output–frame 0.5 kV, 1 minute. | ||||
| इन्सुलेशन प्रतिरोध | 100 MΩ at 500 V DC, 25 °C and 70% RH (input–output, input–frame and output–frame). | ||||
| वज़न | 0.23 kg | ||||
| पैकिंग | 44×36.5×19.5CM/80PCS/16kg | ||||
| उत्पादन | मौजूदा | क्षमता | लहर (mVp-p) |
|---|---|---|---|
| 5 V | 0–12 A | 86% | 120 |
| 12 V | 0–5 A | 86% | 120 |
| 15 V | 0–4 A | 88% | 120 |
| 24 V | 0–2.5 A | 88% | 150 |
| 48 V | 0–1.3 A | 90% | 200 |
| इनपुट वोल्टेज रेंज | 300–450 V AC, 47–63 Hz / 420–635 V DC |
|---|---|
| DIMENSIONS | 99 × 82 × 30 mm |
| कार्य तापमान | −20 to +70 °C; full-load operation across this range is not specified. |
| रेखा विनियमन | ±0.5% |
| लोड विनियमन | ±0.5% |
| आउटपुट वोल्टेज समायोजन | ±10% |
| Inrush current | Consult WEHO for 380 V AC test report |
| अधिभार संरक्षण | 110–150%: output cuts off and recovers automatically. |
| अन्य सुरक्षा | Overcurrent and short-circuit protection. |
| Timing (setup / rise / hold-up) | Consult WEHO for 380 V AC test report |
| वोल्टेज का सामना करें | Input–output 1.5 kV; input–frame 1.5 kV; output–frame 0.5 kV, 1 minute. |
| इन्सुलेशन प्रतिरोध | 100 MΩ at 500 V DC, 25 °C and 70% RH (input–output, input–frame and output–frame). |
| वज़न | 0.23 kg |
| पैकिंग | 44×36.5×19.5CM/80PCS/16kg |
99 × 82 × 30 mm (L × W × H)
Drawing dimensions are in millimetres. Verify terminal markings on the unit before installation.
The operating range is −20 to +70 °C. A load-versus-temperature curve for this model is not supplied here. Confirm the permissible load at your actual cabinet temperature.
For a instrument interface, compare the LRH-60-24 version (24 V · 0–2.5 A) with the total DC demand, including start-up. The 99 × 82 × 30 mm figure is the enclosure size, not the full service clearance.
| विशेषता | What to check |
|---|---|
| Output trim | Use the ±10% adjustment to fine-tune the rail within the load’s voltage limits. |
| Low-profile case | Allow space beyond the housing for airflow, wiring bends and access to the terminals. |
| Overload recovery | The output cuts off during overload and recovers automatically. Check how the equipment restarts. |
Check 300–450 V AC at 47–63 Hz / 420–635 V DC at the installation point.
Allow for the 99 × 82 × 30 mm enclosure, terminal access and cable bends.
Check the temperature near the supply during the longest duty cycle.
Assess what the connected equipment does when DC power returns.
Size the supply for the auxiliary electronics, not for the whole machine.
The HMI screen and tactile pushbuttons are examples of low-voltage loads to check when sizing a 380 V AC auxiliary supply for an operator station. The spindle drive is a separate load.
Size the 380 V AC-input auxiliary supply for safety light curtains, optical sensors and I/O modules—not for the robotic arm servo drives.
Account separately for the machine-vision camera, coaxial ring light and linear-stage controller loads when sizing the 380 V AC auxiliary supply.
AI-generated application illustrations for selection planning; not photographs of verified installations.
Each voltage is a separate version. 5 V, 12 V, 15 V, 24 V and 48 V are listed.
300–450 V AC, 47–63 Hz / 420–635 V DC
No full-load limit at that temperature is established here. Ask for the permitted load in your mounting conditions.
Include LRH-60, desired output, continuous and start-up current, quantity and destination.
Use the theme inquiry form on this product page. Selected model: LRH-60-5LRH-60-12LRH-60-15LRH-60-24LRH-60-48.









WEHO गुणवत्ता वाले बिजली आपूर्ति उत्पादों के साथ अपने व्यवसाय को बढ़ावा दें।.
किसी विशेषज्ञ से पूछें