AC to DC DIN Rail Power Supply 60W 5V 12V 24V 48V Ultra Slim Step Shape DIN Rail HDR-60
WEHO’s HDR-60 is a compact, single-output DIN-rail power-supply family for panel-mounted control, sensing and communications electronics. Separate 5V, 12V, 24V, 48V versions support voltage-specific selection, while the 52.5×90×54.5mm body gives a defined mechanical envelope. Match the selected model’s current rating and actual installation conditions before ordering.
यदि आपके कोई प्रश्न हैं, तो कृपया हमसे संपर्क करने में संकोच न करें ईमेल: [email protected]
- विवरण
| नमूना | HDR-60-5 | HDR-60-12 | HDR-60-24 | HDR-60-48 |
| DC output voltage, current | 5V 0~6.5A | 12V 0~4.5A | 24V 0~2.5A | 48V 0~1.25A |
| Wave And Noise | 80mVp-पी | 120mVp-पी | 150mVp-पी | 240mVp-पी |
| Inlet Wire Stability | ±1% | ±1% | ±1% | ±1% |
| Load Stability | ±1% | ±1% | ±1% | ±1% |
| क्षमता | 82% | 85% | 88% | 88% |
| Adjustable Range For DC Voltage | ±10% | ±10% | ±10% | ±10% |
| इनपुट वोल्टेज रेंज | 85~264VAC/120~370VDC; 47~63Hz | |||
| Impact Current | Cold start current: 30A/115VAC; 60A/230VAC | |||
| अधिभार संरक्षण | 105%~150% cut off the output, automatic recovery | |||
| ओवरवॉल्टेज संरक्षण | 115%~140% rated output power. Protection type: Hiccups mode, recovers automatically after fault condition is removed | |||
| Setup, Rise, Hold Up Time | 1500ms, 80ms/230VAC; 1500ms, 80ms/115VAC (at full load) | |||
| वोल्टेज का सामना करें | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||
| अलगाव प्रतिरोध | I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC / 25℃ / 70%RH | |||
| Working Temperature | -20℃~+70℃ | |||
| आयाम | 52.5×90×54.5mm | |||
| वज़न | 0.19kg | |||
Why choose HDR-60?
Defined mechanical envelope
The stated body dimensions are 52.5×90×54.5mm. Use these dimensions to allocate panel space, then check the complete drawing, terminal access and nearby equipment.
Distinct single-output versions
The listed versions are HDR-60-5, HDR-60-12, HDR-60-24, HDR-60-48. Each is a single-output model, not a simultaneous multi-voltage supply. Match the selected version to the equipment input.
Documented input coverage
The specified input ranges are 85–264VAC and 120–370VDC, with an AC frequency range of 47–63Hz. Confirm the actual source, wiring requirements and supplied revision.
Defined overload recovery
Overload protection is listed at 105%~150% with output cut-off and automatic recovery. Coordinate the supply and downstream load so a fault response is not treated as normal continuous operation.
Feature Of 60W Ultra Slim Step Shape DIN Rail Power Supply
Model-specific output information
HDR-60-5: 5V 0~6.5A; HDR-60-12: 12V 0~4.5A; HDR-60-24: 24V 0~2.5A; HDR-60-48: 48V 0~1.25A. Keep each current range with its stated model; the family designation does not establish one continuous-power rating for every output option.
Regulation and adjustment
Line regulation and load regulation are each listed as ±1%. The DC voltage adjustment range is ±10%; confirm the connected electronics input limits before adjusting the setting.
Noise and efficiency data for selection
Ripple/noise: HDR-60-5: 80mVp-p; HDR-60-12: 120mVp-p; HDR-60-24: 150mVp-p; HDR-60-48: 240mVp-p. Efficiency: HDR-60-5: 82%; HDR-60-12: 85%; HDR-60-24: 88%; HDR-60-48: 88%. Use the selected model figures in the load noise and power-budget assessment.
Model-specific terminal information
Pins 1 and 2: -V; pins 3 and 4: +V; pin 5: AC/L; pin 6: AC/N. The drawing specifies TS35/7.5 or TS35/15 DIN rails. Follow the complete drawing and the installation electrical-safety requirements.
Typical service conditions
Panel space and mechanical fit
Plan around the 52.5×90×54.5mm body and 0.19kg stated weight. The drawing specifies TS35/7.5 or TS35/15 DIN rails. Allow for wiring and the surrounding equipment; the body dimensions are not a universal clearance specification.
Input and terminal checks
Check the actual supply against 85–264VAC or 120–370VDC and the 47–63Hz AC range. Pins 1 and 2: -V; pins 3 and 4: +V; pin 5: AC/L; pin 6: AC/N. Confirm DC-input wiring for the selected revision rather than assuming AC labels alone define every DC installation.
Temperature and load planning
The working-temperature range is -20°C to +70°C. Assess the real enclosure, airflow and selected output load; the stated temperature range alone does not establish full output at every ambient temperature.
Start-up and fault coordination
Timing information is listed as 1500ms, 80ms/230VAC; 1500ms, 80ms/115VAC (at full load). Cold-start current is 30A/115VAC; 60A/230VAC. Keep these figures with their stated input conditions when coordinating upstream protection and downstream start-up.
Application guidance
These are potential integration roles, not customer-installation claims. Match the selected voltage, steady-state current, start-up demand and environment before selection.
Access-control electronics
Use a voltage-compatible HDR-60 version for reader, controller or interface electronics inside a protected access-control panel. Assess door strikes, motors and pulsed loads separately; a matching nominal voltage alone does not establish suitability.
Process sensing and monitoring
Provide local DC power to compatible sensor interfaces, monitoring modules or indication electronics with the selected HDR-60 voltage. Check steady-state and start-up demand and compare ripple/noise with the measurement-system requirements.
Building-automation interfaces
Supply compatible zone-controller or building-management interface electronics in a protected panel. Check the HDR-60 mechanical envelope, panel temperature and load input limits; the supply alone does not establish outdoor or system-level approval.
Industrial communications equipment
Power compatible gateways, serial-interface modules or local communications electronics that accept the selected HDR-60 DC input. Verify the whole load budget and start-up conditions; this selection does not add PoE, backup or UPS functions.
HDR-60 technical FAQs
Which DC output models are listed for HDR-60?
The listed models are HDR-60-5, HDR-60-12, HDR-60-24, HDR-60-48, with nominal outputs of 5V, 12V, 24V, 48V respectively. Each is a single-output version.
What current ratings are listed for HDR-60?
HDR-60-5: 5V 0~6.5A; HDR-60-12: 12V 0~4.5A; HDR-60-24: 24V 0~2.5A; HDR-60-48: 48V 0~1.25A. Keep each current range with its exact output model and assess the actual load and operating conditions.
What input-voltage and frequency ranges are specified?
The input-voltage ranges are 85–264VAC and 120–370VDC. The AC frequency range is 47–63Hz. Check the selected unit and installation requirements before connection.
What line-regulation and load-regulation figures are listed?
Line regulation and load regulation are each listed as ±1% for every output version in this family.
What DC voltage adjustment range is listed?
The listed DC voltage adjustment range is ±10% for each version. Verify the connected equipment input limits before changing the setting.
What ripple/noise values are listed for HDR-60?
HDR-60-5: 80mVp-p; HDR-60-12: 120mVp-p; HDR-60-24: 150mVp-p; HDR-60-48: 240mVp-p. Confirm any application-specific measurement conditions separately.
What efficiency values are listed for HDR-60?
HDR-60-5: 82%; HDR-60-12: 85%; HDR-60-24: 88%; HDR-60-48: 88%. Use the figure for the selected voltage version.
What cold-start current is specified?
The listed cold-start current is 30A/115VAC; 60A/230VAC. Keep each value tied to its stated AC input when assessing upstream protection.
How is overload recovery specified?
The overload range is 105%~150%, with output cut-off and automatic recovery. Do not treat the protection threshold as a normal continuous operating rating.
What timing information is provided?
The timing row lists 1500ms, 80ms/230VAC; 1500ms, 80ms/115VAC (at full load). A separate third hold-up-time value is not printed in that row.
What working-temperature range and dimensions are stated for HDR-60?
The stated working-temperature range is -20°C to +70°C. Body dimensions are 52.5×90×54.5mm and weight is 0.19kg. Verify thermal performance with the actual load and enclosure rather than assuming full output at every temperature.
Which terminal assignments are shown for HDR-60?
Pins 1 and 2: -V; pins 3 and 4: +V; pin 5: AC/L; pin 6: AC/N. The drawing specifies TS35/7.5 or TS35/15 DIN rails. Use the complete drawing and applicable installation instructions for final integration.