PSC-100 12V 24V Ac to Dc Ups 3 Years Warranty Switching Power Supply
This 100W UPS-integrated power supply offers 12V/5A or 24V/2.5A outputs, with adjustable voltage ranges and 89% efficiency. It ensures uninterrupted power via automatic AC/battery and cold-start functionality. Built for reliability, it includes overload protection (105–115% load), hiccup-mode short-circuit recovery, and low-battery protection. The 129×97×30mm chassis (0.42kg) operates in -20°C to +60°C environments, suitable for POS systems, telecom equipment, and low-power industrial devices requiring stable backup power. Universal input (90–264VAC) and LED status indicators enhance versatility.
- विवरण
| Model | PSC-100-12 | PSC-100-24 | ||
| DC Output Voltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2:27.6V |
| Output Voltage Tolerance | ±1% | —– | ±1% | —– |
| Rated Output Current | 5.0A | 2A(charge) | 2.5A | 1A(charge) |
| Output Current Range | 0~7A | —– | 0~3.5A | —- |
| Output Power | 100W | 100W | ||
| Ripple and Noise | 150mVp-पी | —– | 200mVp-पी | —– |
| Adjustable Range of DC Voltage | CH1:11.3~14.9V | CH1:21.3~29.8V | ||
| Start-up,Rise,and Hold Time | 600ms,50ms,80ms/230VAC.1200ms.50ms.16ms/115VAC. | |||
| Input Voltage Range | 90~264VACor 135~370VDC | |||
| ACInput Current | 2.4A/115VAC 1.2A/230VAC | |||
| क्षमता | 87% | 89% | ||
| Inrush Current | Cold Start Current 30A/115VAC 50A/230VAC | |||
| Leakage Current | <lmA/240VAC | |||
| Overload Protection | Overload protection will be activated at 105%to 115%of the rated output power. | |||
| Protection mode:ACcharging mode:Isolation mode,the system can automatically resume operation after the abnormal load condition is removed. | ||||
| Low Battery Voltage Protection | 9.5~10.3V | 19~20.5V | ||
| Protection mode:Output cut-off. | ||||
| Introduction to UPS Function | Long-term online float charging for batteries with high efficiency,over 97%fullness. | |||
| Automnaicalysopschargng when fltopeventovechargeandextendbaterylfe. | ||||
| Automatic switch between utility power and battery without delay,nomanual operation needed. | ||||
| Cold start capability allows UPSto start directly from battery in case of no utility power,meeting emergency needs. | ||||
| Operating Temperature and Humidity | -20°Cto~60°C;20%~90%RH(Please refer to theload derating curve). | |||
| Storage Temperature and Humidity | -20℃~+85C;10%~95%RHNon-condensing | |||
| Shock Resistance | 10~500Hz,2G 10min./per cycle,duration 60 minutes,on each axis | |||
| Voltage Withstanding Capability | Between input and output:1.5kVAC Between input and ground:1.5kVAC Between output and ground:0.5kVDC | |||
| Insulation Resistanc | Between input and output,input and ground,output and ground:100MQ/500VDC | |||
| Dimensions | 129*97*30mm(L*W*H) | |||
| Packaging | 0.42kg/50pcs/21.5kg/0.041m³ | |||