PSC-100 12V 24V Ac ke Dc Menaikkan 3 Tahun Waranti Bekalan Kuasa Penukaran
The WEHO PSC-100 is a power supply with a battery-charging function and requires a compatible external battery for backup operation. PSC-100-12: CH1 load output 13.8V, 5A; CH2 charging output 13.8V, 2A. PSC-100-24: CH1 load output 27.6V, 2.5A; CH2 charging output 27.6V, 1A. Input: 90–264VAC or 135–370VDC. In AC charging mode, overload protection operates at 105%–115% of rated output power in hiccup mode, with automatic recovery after the abnormal load is removed. Confirm battery compatibility and the load/charging power allocation for the application; the 100W series figure must not be treated as 100W available solely to the load.
Email Kami [email protected]
- Penerangan
| Model | PSC-100-12 | PSC-100-24 | ||
| Voltan output DC | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2:27.6V |
| Toleransi voltan output | ± 1% | —– | ± 1% | —– |
| Arus output undian | 5.0A | 2A(caj) | 2.5A | 1A(caj) |
| Output julat semasa | 0~7A | —– | 0~3.5A | —- |
| Kuasa output | 100W | 100W | ||
| Riak dan Kebisingan | 150mvp-p | —– | 200mvp-p | —– |
| Julat Voltan DC Boleh Laras | CH1:11.3~14.9V | CH1:21.3~29.8V | ||
| Masa Permulaan, Bangkit dan Tahan | 600ms,50ms,80ms/230VAC.1200ms.50ms.16ms/115VAC. | |||
| Julat voltan input | 90~264VACor 135~370VDC | |||
| ACInput Arus | 2.4A/115VAC 1.2A/230VAC | |||
| Kecekapan | 87% | 89% | ||
| Arus Masuk | Arus Mula Sejuk 30A/115VAC 50A/230VAC | |||
| Arus kebocoran | <lmA/240VAC | |||
| Perlindungan beban | Perlindungan beban lampau akan diaktifkan pada 105%to 115%of kuasa output terkadar. | |||
| Protection mode in AC charging operation: hiccup mode; operation resumes automatically after the abnormal load condition is removed. | ||||
| Perlindungan Voltan Bateri Rendah | 9.5~10.3V | 19~20.5V | ||
| Mod perlindungan: Output cut-off. | ||||
| Pengenalan kepada Fungsi UPS | Pengecasan apungan dalam talian jangka panjang untuk bateri dengan kecekapan tinggi, melebihi 97%fullness. | |||
| Confirm the compatible battery type, charging limits and charge-termination behavior for the application. | ||||
| Automatic switch between utility power and battery without delay,no manual operation needed. | ||||
| Keupayaan permulaan sejuk membolehkan UPS dimulakan terus dari bateri sekiranya tiada kuasa utiliti, memenuhi keperluan kecemasan. | ||||
| Suhu dan Kelembapan Operasi | -20°Cto~60°C;20%~90%RH(Please refer to the load derating curve). | |||
| Suhu dan Kelembapan Penyimpanan | -20℃~+85C;10%~95%RHBukan pemeluwapan | |||
| Shock resistance | 10~500Hz, 2G 10min./setiap kitaran, tempoh 60 minit, pada setiap paksi | |||
| Keupayaan Menahan Voltan | Antara input dan output:1.5kVAC Antara input dan ground:1.5kVAC Antara output dan ground:0.5kVDC | |||
| Rintangan penebat | Antara input dan output, input dan ground, output dan ground: 100MQ/500VDC | |||
| Dimensi | 129*97*30mm(L*W*H) | |||
| Pembungkusan | 0.42kg/50pcs/21.5kg/0.041m³ | |||