| विनिर्देश | S-400-5 | S-400-12 | S-400-24 | S-400-48 |
| डीसी आउटपुट वोल्टेज, करंट | 5V 0 ~ 60A | 12V 0 ~ 33A | 24V 0 ~ 16.5A | 48V 0 ~ 8.3A |
| लहर और शोर | 100mVp-पी | 150mVp-पी | 150mVp-पी | 200mVp-पी |
| इनलेट तार स्थिरता | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| लोड स्थिरता | ±1% | ±0.5% | ±0.5% | ±0.5% |
| क्षमता | 73% | 74% | 81% | 83% |
| डीसी वोल्टेज के लिए समायोज्य रेंज | ±10% | ±10% | ±10% | ±10% |
| इनपुट वोल्टेज रेंज | 90 ~ 132VAC/180 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz | |||
| प्रभाव धारा | कोल्ड स्टार्ट करंट 25A/115VAC 50A/230VAC | |||
| अधिभार संरक्षण | 105% ~ 135% cut off the output, automatic recovery | |||
| ओवरवॉल्टेज संरक्षण | 115% ~ 150% shut down O/P voltage, re-power on to recover | |||
| सेटअप, उदय, होल्ड अपटाइम | 200ms, 50ms, 20ms/230VAC at full load | |||
| वोल्टेज का सामना करें | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||
| अलगाव प्रतिरोध | I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ | |||
| कार्य तापमान | -10°C ~ +50°C | |||
| आयाम | 215 × 115 × 50mm | |||
| वज़न | 1.1kg | |||
| पैकिंग | 45.5 × 31.5 × 26CM/20PCS/22kg | |||
S-400W series normal single switching power supply
WEHO S-400 is a single-output switching power supply with 5V, 12V, 24V and 48V variants. It provides a suffix-specific DC choice for compatible job-interface, display and communication electronics in equipment such as a label-inspection rewinder. The documented adjustment, regulation and protection rows help an equipment builder compare the electronic branch with its actual requirements. Select the exact output, input configuration and enclosure design before integration; request a quotation with the board voltage, current profile and operating environment.
यदि आपके कोई प्रश्न हैं, तो कृपया हमसे संपर्क करने में संकोच न करें ईमेल: [email protected]
- विवरण
Why Choose S-400
Select the electronic branch, not just the power class
The S-400-5 column specifies 5V at 0 ~ 60A. This makes the low-voltage option identifiable at procurement instead of treating every S-400 as the same output. Check the remaining suffix columns and the real board demand before placing one variant on a bill of materials; the series name is not an interchangeable electrical specification.
Plan the input configuration across plants
AC input is 90 ~ 132VAC or 180 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. The printed switch selection supports a deliberate input-configuration check when a machine is supplied for different plant mains. Include selector verification in the equipment build specification; do not describe these bands as automatic universal input.
Budget a defined enclosure footprint
The dimension row is 215 × 115 × 50mm and the weight row is 1.1kg. These figures give cabinet designers a concrete starting point for space and support planning. The drawing also needs to be reviewed for fixing geometry and access; neither the body-size row nor the mass proves drop-in replacement fit or an installation clearance.
Trim only within a matched board input range
DC voltage adjustment is ± 10% for each listed output. A documented adjustment provision helps specify a final electronic supply setting. Verify the measured setting at the connected board and its allowed tolerance; adjustment is not a way to turn the selected output into another suffix or increase continuous capacity.
S-400 Features and Selection Value
Check output-specific regulation
Inlet wire stability is ± 0.5% for each listed output. Load stability is S-400-5: ± 1%; S-400-12: ± 0.5%; S-400-24: ± 0.5%; S-400-48: ± 0.5%. The separate load-stability figure on the low-voltage column matters when comparing electronics with tight input limits; assess the 5V output against its own ± 1% load-stability entry.
Match the printed noise limit to the electronics
Wave-and-noise values are S-400-5: 100mVp-p; S-400-12: 150mVp-p; S-400-24: 150mVp-p; S-400-48: 200mVp-p. These output-specific values help screen the receiving board noise requirement. They are not a universal noise guarantee at every wiring arrangement or an assurance of precision-measurement performance.
Use the selected output efficiency
Listed efficiencies are S-400-5: 73%; S-400-12: 74%; S-400-24: 81%; S-400-48: 83%. Use the figure attached to the chosen column when planning the equipment heat review. The table does not state a universal efficiency across all outputs, temperatures or operating points.
Distinguish fault recovery actions
Overload protection is 105% ~ 135%; it cuts off the output with automatic recovery. Overvoltage protection is 115% ~ 150%; it shuts down the output voltage and requires re-powering to recover. The different recovery actions matter to fault handling: arrange branch protection and equipment reset behavior so that supply recovery cannot create an unsafe process restart.
Typical Service Conditions
Keep process fumes outside the electrical bay
The printed working-temperature range is -10°C ~ +50°C. A laser engraving enclosure may evaluate an exact S-400 output for compatible job-interface and status boards in a protected electrical section. Keep fumes and conductive debris away from the supply, maintain the engineered airflow path and check the actual compartment temperature. Laser emission, extraction, motion and protective interlocks remain independently powered and validated.
Limit dust and vibration at a panel saw
At a panel-saw workcell, a selected S-400 variant may serve compatible order-display and communication boards only after the required DC input is checked. Design dust exclusion, cable restraint and secure mounting for the real enclosure. Saw drives, extraction, feed equipment and operator protection are separate systems; a metal supply housing is not a dust-tight installation.
Separate heat from a print-finishing laminator
A print-finishing laminator may assess a qualified S-400 suffix for compatible recipe-entry and local logic boards. Locate the electrical section away from hot rollers and verify temperature during the complete operating cycle, including idle heat soak. Roller drives, heaters and temperature regulation are not assigned to the supply, and the timing specification is not a thermal-load guarantee.
Check restart behavior in a carton-erecting cell
For a carton-erecting cell, consider a selected S-400 output for compatible format-interface and diagnostic boards. Validate startup demand and the response to repeated power interruptions before tying electronic reset to a production sequence. Forming actuators, vacuum generation and protective controls require independent qualification; automatic overload recovery must not create an unexpected machine restart.
Potential S-400 Equipment Applications
Label-inspection rewinder
A label-inspection rewinder may consider an exact S-400 variant for compatible job-selection and status electronics. Match the board voltage and startup demand, and check whether its noise tolerance accepts the selected output specification. Web tension drives, inspection lighting and defect-measurement performance are separate requirements, not benefits established by the power-supply choice.
Vibration-test station
A vibration-test station may evaluate a selected S-400 output for compatible sequence-interface and non-measurement status boards. Keep the supply outside the deliberately vibrating fixture where the enclosure design permits, then verify cable support and environmental exposure. Shaker power, calibrated acquisition channels and test accuracy are independently specified.
Tool-presetting bench
A tool-presetting bench may assess a qualified S-400 suffix for compatible job-record and communication boards. Confirm their DC range, grounding plan and acceptable ripple before integration. Optical references, measurement transducers and dimensional accuracy need their own power and qualification; the supply is not proposed as a calibrated reference.
Ultrasonic parts-cleaning line
An ultrasonic parts-cleaning line may evaluate an exact S-400 variant for compatible cycle-display and communication boards in a dry electrical bay. Separate the supply from mist, wash fluids and condensation, and validate interruption handling. Ultrasonic generators, pumps and tank heaters remain separately powered; neither the supply nor the assembly acquires washdown suitability from this concept.
S-400 Technical FAQs
Which output variants and current ranges are listed for S-400?
S-400-5: 5V, 0 ~ 60A; S-400-12: 12V, 0 ~ 33A; S-400-24: 24V, 0 ~ 16.5A; S-400-48: 48V, 0 ~ 8.3A. The summary describes a single-output 400W series. Select one exact output rather than combining column maxima. The printed current range is not a separate continuous power rating, a constant-current function or proof of load-free behavior. The final continuous load, startup margin and thermal conditions require a variant-specific engineering decision; multiplying voltage and current does not replace that decision.
What input ranges and selection method are specified for S-400?
AC input is 90 ~ 132VAC or 180 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. Verify the actual input source and the delivered selector setting before energizing. The AC bands are switch-selected, not a continuous automatic input range. A printed DC range alone does not approve DC wiring, source protection or a battery installation.
How should the S-400 cold-start current figures be interpreted?
Cold-start current is 25A at 115VAC and 50A at 230VAC. These are input inrush figures at the two printed AC conditions, not the normal input current or the available DC output current. Check upstream switching and protection against the actual equipment startup sequence; no new breaker or fuse rating is inferred.
What setup, rise and hold-up times are printed for S-400?
Setup, rise and hold-up times are 200ms, 50ms, 20ms, respectively, at 230VAC at full load. The values follow the printed label order and belong to that stated input/load condition. Hold-up time is not stored-energy backup, a UPS function or proof that the connected controller will ride through every interruption. The timing-only full-load condition does not approve full-load operation throughout the temperature range.
What wave-and-noise value applies to each S-400 output?
S-400-5: 100mVp-p; S-400-12: 150mVp-p; S-400-24: 150mVp-p; S-400-48: 200mVp-p. Apply the value specified for the selected output. The sheet does not turn these figures into a guarantee for every cable, load waveform or measurement setup. Check the receiving electronics and the complete grounding and wiring arrangement before accepting a noise-sensitive load.
How do S-400 regulation and voltage adjustment differ?
Inlet wire stability is ± 0.5% for all listed outputs. Load stability is S-400-5: ± 1%; S-400-12: ± 0.5%; S-400-24: ± 0.5%; S-400-48: ± 0.5%. DC voltage adjustment is ± 10% for each listed output. Inlet regulation, load regulation and output adjustment describe different selection questions. Do not reinterpret a regulation figure as voltage accuracy, or use the adjustment range as permission to exceed the receiving board input limit or the selected variant load boundary.
Which efficiency figure belongs to each S-400 variant?
S-400-5: 73%; S-400-12: 74%; S-400-24: 81%; S-400-48: 83%. Each percentage belongs to its own output column. The sheet does not state a common efficiency for every variant or all operating points. Use the actual equipment operating conditions for the thermal design rather than selecting a column maximum for the entire series.
What overload action and recovery behavior are specified for S-400?
Overload protection is 105% ~ 135%; it cuts off the output with automatic recovery. The printed percentage interval is a protection threshold range, not a normal constant-current control range. Coordinate the electronic branch protection and load-reset behavior so that automatic supply recovery cannot initiate an unintended machine cycle.
What overvoltage action and recovery behavior are specified for S-400?
Overvoltage protection is 115% ~ 150%; it shuts down the output voltage and requires re-powering to recover. The recovery action differs from the overload row. Resolve the cause of the event and the equipment restart procedure before re-energizing; this is not an automatic overvoltage-reset claim, a redundant protective system or a safety-rated shutdown.
What temperature and moisture boundaries are documented for S-400?
The printed working-temperature range is -10°C ~ +50°C. Storage temperature, working humidity and storage humidity are not specified on this sheet. The sheet provides no load-versus-temperature curve or full-load approval across that entire range. Establish the actual electrical-bay temperature, airflow and electronic demand for the installed equipment. Confirm storage and moisture limits separately with the manufacturer.
What dimensions and terminal legend are printed for S-400?
The dimension row is 215 × 115 × 50mm and the weight row is 1.1kg. The 135mm drawing span is a separate outer mounting reference, not a replacement for the 115mm body-width entry. The drawing assigns AC input to pins 8 and 9, GND to pin 7, DC output -V to pins 4, 5 and 6, and DC output +V to pins 1, 2 and 3. This is the generic source drawing legend, not a delivered-variant wiring instruction. Confirm the actual terminal order, ratings, conductor requirements, bonding, permitted links and fixing geometry on the selected unit before connection. No series/parallel interconnection, clearance or drop-in replacement fit is established.
What insulation tests are listed, and what approvals do they not establish for S-400?
Withstand values are I/P-O/P: 1.5kV, I/P-FG: 1.5kV and O/P-FG: 0.5kV for 1minute, without a printed AC/DC qualification. Isolation resistance is listed as 500VDC/100MΩ for I/P-O/P, I/P-FG and O/P-FG. These printed test entries are not a product certification, an ingress-protection rating or proof of system safety. PFC, an IP rating and certification scope are not documented on this sheet; any such procurement requirement needs separate exact-model evidence. No warranty term is inferred.
पूछे जाने वाले प्रश्न
Q1: How do I determine whether a 400W switching power supply is sufficient for my equipment?
Calculate the maximum power consumption of all connected devices and compare it with the power supply’s rated capacity. The total continuous load should stay below 400W, while additional headroom should be reserved for startup current, temporary load increases, and high-temperature operation.
Q2: What applications can use the S-400W switching power supply?
The S-400W series is suitable for industrial automation, machinery, control systems, LED equipment, communication devices, electronic equipment, and other systems that require a stable single DC output.
Q3: How much power headroom should I leave when using a 400W power supply?
The correct power margin depends on the application, but continuously operating at the absolute maximum rating is generally not recommended. Equipment with motors, relays, capacitive loads, or other high-startup-current components may require more headroom.
Q4: What are the advantages of a 400W switch mode power supply?
A 400W switching power supply provides good power density, high efficiency, compact size, and lower heat loss compared with many linear power supplies. These characteristics make it practical for industrial equipment and control systems with limited installation space.
Q5: How do I choose the correct output voltage for the S-400W series?
The output voltage must match the rated DC input voltage of the connected equipment. Before ordering, check the equipment specification, maximum current requirement, wiring distance, and total power demand. Using the wrong voltage can damage the connected load.
आपके व्यवसाय के लिए सर्वोत्तम विद्युत आपूर्ति उत्पाद कौन से हैं?
WEHO गुणवत्ता वाले बिजली आपूर्ति उत्पादों के साथ अपने व्यवसाय को बढ़ावा दें।.
किसी विशेषज्ञ से पूछें