LRS Series Enclosed Switching Power Supplies

WEHO LRS series enclosed power supplies convert AC input to a single DC output for control panels, automation equipment and general DC loads. The range includes 35W–600W catalogue classes, multiple output-voltage versions and ventilated enclosures. Input arrangements, cooling and enclosure dimensions vary by model, providing options for different load and installation requirements.

WEHO manufacturingDiscuss OEM and bulk project requirements.
Exact-model datasheetsDirect PDF access for every model shown.
Verifiche di installazioneCompare dimensions, terminals and mounting.
Cifre del progettoConfirm quantity, delivery and compliance needs.

Explore LRS Series Models

Single-output enclosed models for a range of DC loads. LRS-350 is shown first; choose an output voltage and power class to narrow the range.

Need help choosing a model?

14 models

View all LRS enclosed models on official website

Power labels are catalogue classes, not a guarantee of identical continuous power at every output voltage. Check the exact output current, ambient conditions and installation requirements in the model datasheet.

Compare LRS Models Before You Specify

Compare electrical options and enclosure sizes in one place. Use the filters above to narrow both the cards and the table.

Open the 14-model comparison table
ModelloPower classIngresso ACDC options24V current24V efficiencyEnclosureL×W×HNext step
LRS-350350W class90–132 / 180–264VAC
By switch
12V / 15V / 24V / 48V0–14.6A88%With fan215×115×30 mmPDF · Citazione
LRS-3535W class85–264VAC12V / 15V / 24V / 48V0–1.5A88%Ventilated metal99×82×30 mmPDF · Citazione
LRS-5050W class85–264VAC12V / 15V / 24V / 48V0–2.2A88%Ventilated metal99×82×30 mmPDF · Citazione
LRS-6060W class85–264VAC12V / 15V / 24V / 48V0–2.5A88%Ventilated metal99×82×30 mmPDF · Citazione
LRS-7575W class85–264VAC12V / 15V / 24V / 48V0–3.2A88%Ventilated metal99×97×30 mmPDF · Citazione
LRS-100100W class85–264VAC12V / 15V / 24V / 48V0–4.5A88%Ventilated metal129×97×30 mmPDF · Citazione
LRS-120120W class85–264VAC12V / 15V / 24V / 48V0–5A88%Ventilated metal129×97×30 mmPDF · Citazione
LRS-150150W class85–264VAC12V / 15V / 24V / 48V0–6.5A89%Ventilated metal159×97×30 mmPDF · Citazione
LRS-200200W class90–132 / 180–264VAC
By switch
12V / 15V / 24V / 48V0–8.8A88%Ventilated metal215×115×30 mmPDF · Citazione
LRS-250250W class90–132 / 180–264VAC
By switch
12V / 15V / 24V / 48V0–10A88%Ventilated metal215×115×30 mmPDF · Citazione
LRS-400400W class90–132 / 180–264VAC
By switch
12V / 15V / 24V / 48V0–16.5A88%With fan215×115×30 mmPDF · Citazione
LRS-450450W class95–132 / 180–264VAC
By switch
12V / 24V / 36V / 48V0–18.7A85%With fan215×115×50 mmPDF · Citazione
LRS-500500W class95–132 / 180–264VAC
By switch
12V / 24V / 36V / 48V0–20A86%With fan215×115×50 mmPDF · Citazione
LRS-600600W class90–132 / 180–264VAC
By switch
5V / 12V / 15V / 24V / 36V / 48V0–25A91%With fanConfirm drawing revisionPDF · Citazione

Current ranges and efficiency figures follow each WEHO datasheet. Efficiency test conditions and load derating must be confirmed for your application. Dimensions refer to the stated enclosure body; mounting ears and terminal clearance require a separate drawing check. Confirm the final LRS-450 power rating and LRS-600 enclosure revision with WEHO before ordering.

Selection & purchasing questions

Are all LRS models 30mm high?

The listed LRS-35 through LRS-400 enclosures are 30mm high. LRS-450 and LRS-500 are 50mm high. Ask WEHO to confirm the applicable LRS-600 dimensions and mechanical drawing before fixing the installation space.

Which models use an AC input selector?

LRS-35 through LRS-150 list an 85–264VAC range. LRS-200, LRS-250, LRS-350, LRS-400 and LRS-600 list 90–132 / 180–264VAC by switch; LRS-450 and LRS-500 list 95–132 / 180–264VAC by switch. Check the exact model and input setting before energizing.

Can I replace an existing power supply with a WEHO LRS?

Compare the required DC output, current, AC input, body dimensions, mounting holes, terminal assignments and cooling clearance. Share the existing model and installation drawing with WEHO for a project-specific comparison; a similar model name alone does not establish interchangeability.

How do I confirm MOQ, lead time and certification?

Send the exact output version, quantity, destination market and any required certificates. WEHO can confirm the quotation, available documentation and delivery schedule for that order.

Need Help Selecting an LRS Power Supply?

Share the exact output voltage and load current, AC input, installation space, operating environment and project quantity. Request a model-specific datasheet and quotation, and let us know if you need mounting, certification or replacement checks.

Your enquiry is saved privately and sent to the WEHO team. Email / WhatsApp remain optional.

LRS Series Application Fields

DC control and auxiliary-power selection for compatible industrial equipment.
High-power industrial CNC fiber laser cutting machine with metal sparks

CNC & Machine Control Cabinets

Use a correctly selected LRS output for compatible DC control electronics and auxiliary loads inside mains-fed machinery. Size motor, spindle and laser power stages separately, including their start-up and transient requirements.

Precision automated assembly machinery line with servo actuators and touch HMI

Assembly & Automation Equipment

Compare the DC voltage and current required by controllers, sensors and compatible valves in an automation panel. Check simultaneous loads, switching transients, wiring protection and enclosure ventilation.

Enclosed industrial 3D printer with visible LRS power supply unit mounted inside lower cabinet

Industrial 3D Printing Equipment

Check the combined current and start-up demand of the printer controller, heaters and compatible actuators. Confirm the exact output version and thermal conditions before continuous operation.

Automated machine vision inspection camera and edge computing unit inspecting machined parts

Machine Vision & Inspection Systems

Match the supply to the specified input range of cameras, inspection controllers and illumination drivers. Review the model-specific ripple figures and the equipment manufacturer’s filtering and wiring requirements.

Commercial building smart access control and security intercom node

Access Control & Security Equipment

Check controller, lock and camera supply requirements separately. Reserve clearance around terminals and the enclosure, and use the exact model drawing rather than a series-wide height assumption.

Modern warehouse automated guided vehicle AGV and robotics

Warehouse Conveyors & Docking Controls

Consider LRS models for compatible DC controls in stationary, mains-fed warehouse equipment. Battery charging, mobile traction and safety functions need their own approved power architecture.

Application illustrations demonstrate representative operating environments. Confirm exact electrical parameters and mechanical dimensions for your design.

Inside WEHO Smart Manufacturing

Discuss model-specific production, inspection and documentation requirements with WEHO.
SMT automated surface-mount placement line

SMT Component Placement

Component placement is one stage of the power-supply manufacturing workflow. Ask WEHO about the bill of materials and component requirements for your selected model and order.

Precision component insertion and dual-wave flow soldering

Through-Hole Assembly & Soldering

Through-hole components and terminal connections require controlled assembly and inspection. Confirm the relevant workmanship and inspection requirements for your project.

Automated dispensing and precision assembly line

Dispensing & Mechanical Assembly

Assembly processes may include material dispensing and mechanical fixation according to the product design. Confirm any special vibration or environmental qualification requirements separately.

Multi-station modular final assembly

Enclosure & Terminal Assembly

Check the selected enclosure, terminal cover, earthing point and any input selector against the exact product design and installation requirements.

Industrial high-temperature burn-in testing chambers

Production Burn-In & Functional Checks

Request the applicable burn-in and functional-test requirements for the selected model and order. Duration, loading and ambient temperature must be confirmed rather than assumed across the series.

Automated electrical parameter and hipot quality testing

Electrical Inspection & Test Records

Request model-specific inspection records and required electrical test conditions. Product isolation ratings, production test voltages and certification scope must be checked separately.

Manufacturing process overview. Contact WEHO for the applicable production and inspection records for your selected model and order.

Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.