Crimp Pull Tests: Separate Joint Strength from Terminal Retention

95bd837f0d66c898 ndr 75 24 application

Key engineering takeaways

  • A destructive wire-to-crimp pull test and terminal retention test load different interfaces.
  • Qualify the exact wire, contact or ferrule, tooling and method combination.
  • Record peak force and failure location against the applicable criteria.
  • Do not transfer a published example force into an undocumented power-supply terminal requirement.

Crimp pull testing verifies a defined wire-to-crimp mechanical connection under a specified method; terminal retention verifies a different interface, such as a contact retained in a housing. A passing result at one interface does not qualify the other. Start by drawing the loaded boundary and identifying the applicable component instructions.

For an assembly incorporating the WEHO NDR-75-24, distinguish any separately prepared wire termination from its connection into the power supply. The model supplies an enquiry identity, not a generic crimp-force specification. The diagrams and sample results below are fictional and do not represent a WEHO test or terminal approval.

NDR-75-24 product installed in an industrial application scene with original housing and label details.
Application illustration of NDR-75-24 in an equipment setting; not a customer installation photo. Scene created with AI assistance. Visualizzare l'immagine in risoluzione originale

Identify the interface before selecting the method

A crimped wire termination contains a conductor-to-terminal connection formed by the approved tooling. A connector assembly may additionally contain a contact-to-housing retention feature. A ferrule prepared for a screw or spring terminal adds another interface when it is installed into the receiving terminal.

Specify which parts the test fixture holds and where the pulling force is applied. If the fixture grips insulation in a way that carries load, the measured result may not represent the intended conductor crimp alone. Follow the applicable test method rather than inventing a gripping arrangement that produces a convenient high force.

Interpower's crimp-quality discussion describes cross-section inspection and pull testing as complementary views of the connection. Mechanical strength alone does not reveal every internal formation problem. Visual, dimensional, sectioning or other evidence may be needed for the actual qualification purpose.

An installed terminal check must also be distinguished from a destructive specimen test. Do not apply a laboratory failure load to a completed power-supply connection unless the applicable procedure explicitly requires it. Destructively tested specimens should be identified and excluded from production use.

Interface Typical question Required method identity Cannot establish alone
Wire to crimped barrel Does the prepared joint meet its criterion? Wire/contact/tool and loading setup Receiving terminal compatibility
Contact to connector housing Is the contact retained as required? Housing/contact and retention direction Crimp formation quality
Ferrule to receiving terminal Is the approved installed connection retained? Terminal instructions and accepted conductor form Every crimp internal characteristic
Harness or cable support Does the intended restraint carry the load? Support geometry and assembly procedure Electrical terminal qualification

Control the complete preparation combination

A wire gauge alone does not identify the crimp process. Record conductor construction and material, insulation preparation, terminal or ferrule part number, tool, die and locator where applicable. Include the controlled setup and inspection requirements that make a later repeat test comparable.

Phoenix Contact's ferrule-processing poster illustrates preparation, crimping and pull-test considerations for its context. Its example force is not a universal value for all ferrules, conductor sizes or receiving terminals. Obtain the criterion governing the exact combination being qualified.

Tool wear, replacement dies or a different wire construction can alter the process without changing the nominal conductor cross-section. Define which changes trigger renewed verification. Retain sample identities so a result can be traced to the specific material and setup rather than an unexplained tool serial number alone.

Sampling frequency also needs an applicable source. A controlled aerospace workmanship document may specify process controls for its own application, but that does not make its schedule a universal OEM factory rule. Agree production checks and reaction plans through the relevant supplier instructions and quality requirements.

NDR-75-24 product reference preserving the original housing, visible label and connection features.
Product appearance reference for NDR-75-24, preserving the source housing, visible label and connections. Visualizzare l'immagine in risoluzione originale

Evaluate a fictional qualification record

Assume a fictional approved wire/contact/tool procedure defines a minimum destructive pull force of 60 N and separately defines acceptable failure modes. Three prepared specimens produce 68 N, 72 N and 65 N. All exceed the assumed numerical minimum, but each still needs its own failure-mode and method review.

The arithmetic margins are 8 N, 12 N and 5 N above 60 N. The mean is (68 + 72 + 65) / 3 = 68.33 N. That mean cannot rescue a specimen below its individual criterion; an acceptance rule must not be changed after observing the results.

Suppose a separate contact-to-housing retention check uses an assumed 40 N criterion and records 35 N. The margin is 35 − 40 = −5 N, so that separate retention requirement is not met. The passing crimp specimens do not cancel it because they loaded a different interface.

Fictional record Observed force Assumed criterion Bounded conclusion
Crimp specimen C1 68 N At least 60 N plus mode criteria Force condition met; review mode
Crimp specimen C2 72 N Same specified method Force condition met; review mode
Crimp specimen C3 65 N Same specified method Force condition met; review mode
Housing retention H1 35 N Assumed at least 40 N Separate retention condition not met

These assumed forces have no relationship to a WEHO terminal rating or an instruction to pull a live assembly. A real report must identify the applicable procedure, force measurement suitability, loading conditions and specimen disposition. Do not reduce the report to an average and a PASS stamp.

Separate fictional records compare crimp strength with housing retention under independently assumed acceptance criteria.
Conceptual Engineering Diagram. Fictional crimp specimens at 68, 72 and 65 N exceed an assumed 60 N force condition; separate 35 N housing retention misses an assumed 40 N condition. These are not WEHO terminal requirements; failure modes and method criteria remain necessary. Apri il diagramma di dimensioni completa

Swipe horizontally on a small screen, or open the full-size diagram.

Failure location helps interpret the measurement but does not replace the defined acceptance criteria. Wire break, conductor withdrawal, barrel failure and other outcomes need the treatment prescribed for that combination. An attractive statement such as “wire broke, therefore pass” is unsafe as a universal quality rule.

Use workmanship references within their scope

NASA-STD-8739.4A with Change 1 contains controlled cable/harness workmanship and crimp-testing provisions in its 2016 publication context. It is useful for understanding the importance of traceable preparation, test conditions and failure records. It is not evidence that an unrelated WEHO assembly follows NASA requirements or that a historical table is contractually applicable.

A receiving terminal can restrict conductor form, size and ferrule geometry independently of a prepared crimp's pull strength. Confirm those restrictions from the actual terminal documentation. A mechanically strong ferrule that cannot be fully inserted or properly clamped still lacks an approved installed connection.

The existing WEHO terminal-torque records article addresses controlled assembly evidence. A crimp qualification record adds the wire-to-prepared-termination process and must retain that distinct boundary. Torque records, crimp strength and connector retention are complementary evidence where applicable, not interchangeable certificates.

Release a boundary-specific test plan

  1. Draw the loaded interface. Identify fixture grips, force direction and the joint being assessed. Record whether the method is destructive; verify that the intended interface carries the measured load.
  2. Identify the combination. List wire, termination, tooling and preparation instructions. Record revisions and specimen traceability; verify compatibility with the actual receiving terminal separately.
  3. Approve the criteria. Obtain force, failure-mode and method requirements from the applicable source. Record sampling and reaction rules; verify that no example value has been borrowed without authorization.
  4. Test and inspect. Use the controlled setup, preserve individual peak forces and examine failure locations. Record deviations; verify each specimen against its own criteria before calculating summaries.
  5. Control the outcome. Exclude destructive specimens from product and disposition any nonconforming process. Record corrective actions and reverification; verify that production resumes only under the approved combination.

Prepare a termination-evidence enquiry

Send WEHO the exact NDR-75-24 enquiry identity, conductor details and proposed termination form. Ask for the applicable receiving-terminal instructions and identify any separate harness supplier qualification you require. Do not treat the fictional 60 N or 40 N criteria as a product specification or standard WEHO inspection service.

Domande frequenti

Does a passing crimp pull test prove connector retention?

No. Wire-to-crimp strength and contact-to-housing retention load different interfaces. Each applicable requirement needs its own evidence and correctly defined method.

Can the average force hide one failed specimen?

No, when individual specimens must meet a minimum. Apply the predetermined acceptance rule to each result; a high average cannot change an individual requirement after testing.

Is wire break always an acceptable failure mode?

No universal rule applies. Interpret the failure mode with the applicable method, force criterion and connection combination. Record the actual location and condition rather than substituting a slogan for acceptance criteria.

Can a tested-to-failure termination be installed afterward?

No. Treat a destructive specimen as test evidence and keep it out of production inventory. Use separately prepared and accepted parts for the released assembly.