NDR-480 Din Rail Power Supply

NDR-480 High Power Din Rail Ac to Dc Switching Power Supply
NDR-480 Series High cost performance,Has extremely high work efficiency High Power Switching Power SupplyNDR-480 Has 24V 48V,Three-year warranty.Protected by fully isolated plastic housing Prevent electric shock93%Ultra-high efficiency,this series can be cooled using only free air convection up to 60°C which significantly increases the reliability and lifetime of the power supply.low no-load power consumption,to save energy, short circuit,overload,over voltage protections.If you interested in This Series,Please contact us at E -mel: [email protected]

NDR-480-24 · photographed sample

NDR-480 Single-Output DIN Rail Power Supply

Choose 24 V or 48 V for a 480 W-class DIN rail supply. Each suffix identifies a separate output version.

Select output voltage
Model
NDR-480-24NDR-480-48
DC output
24 V · 0–20 A48 V · 0–10 A
Input AC
85–264 VAC
DC input
120–370 VDC
Kecekapan
92.5%92.5%
Dimensi
85 / 85.5 × 125.2 × 128.5 mm

Specifications & models

ParameterNDR-480-24NDR-480-48
DC output voltage and current24 V · 0–20 A48 V · 0–10 A
Kecekapan92.5%92.5%
Ripple and noise150 mV p-p150 mV p-p
Peraturan garis± 0.5%± 0.5%
Peraturan beban± 1%± 1%
DC voltage adjustment± 10%± 10%
Input AC85–264 VAC
DC input120–370 VDC
Dimensi85 / 85.5 × 125.2 × 128.5 mm
Family power class480 W (single output)
Input frequency47–63 Hz
Cold-start inrush20 A at 115 VAC; 35 A at 230 VAC
Perlindungan beban105–150%: output cutoff; automatic recovery.
Perlindungan voltan lampau120–140%: output shuts down. Reapply power to recover.
Setup / rise1500 / 100 ms at 230 VAC, full load. Hold-up time is not specified.
Menahan voltanInput/output: 3 kV; input/FG: 2 kV; output/FG: 0.5 kV; 1 minute.
Rintangan penebatInput/output, input/FG and output/FG: 100 MΩ at 500 VDC.
Working environment−10 to +50 °C
Unit weight1.5 kg
Pembungkusan8 pcs / 13 kg
Output options
ModelOutputCurrentKecekapan
NDR-480-2424 V0–20 A92.5%
NDR-480-4848 V0–10 A92.5%
Additional model specifications
NDR-480-24
Ripple and noise150 mV p-p
Peraturan garis± 0.5%
Peraturan beban± 1%
DC voltage adjustment± 10%
NDR-480-48
Ripple and noise150 mV p-p
Peraturan garis± 0.5%
Peraturan beban± 1%
DC voltage adjustment± 10%
Common specifications
Input AC85–264 VAC
DC input120–370 VDC
Dimensi85 / 85.5 × 125.2 × 128.5 mm
Family power class480 W (single output)
Input frequency47–63 Hz
Cold-start inrush20 A at 115 VAC; 35 A at 230 VAC
Perlindungan beban105–150%: output cutoff; automatic recovery.
Perlindungan voltan lampau120–140%: output shuts down. Reapply power to recover.
Setup / rise1500 / 100 ms at 230 VAC, full load. Hold-up time is not specified.
Menahan voltanInput/output: 3 kV; input/FG: 2 kV; output/FG: 0.5 kV; 1 minute.
Rintangan penebatInput/output, input/FG and output/FG: 100 MΩ at 500 VDC.
Working environment−10 to +50 °C
Unit weight1.5 kg
Pembungkusan8 pcs / 13 kg

Dimensions & technical notes

Mechanical dimensions

85 / 85.5 × 125.2 × 128.5 mm

Side elevation
NDR-480 side elevation from the WEHO drawing.

Side elevation from the model sheet; dimensions in mm.

Front elevation
NDR-480 front elevation from the WEHO drawing.

Front elevation from the model sheet; dimensions in mm.

Top view
NDR-480 top view from the WEHO drawing.

Top view from the model sheet; dimensions in mm.

Bottom view
NDR-480 bottom view from the WEHO drawing.

Bottom view from the model sheet; dimensions in mm.

TB1: 1 = FG; 2 = AC/N or DC −; 3 = AC/L or DC +.

TB2: 4 and 5 = −V; 6 and 7 = +V.

The dimension table gives 85 mm for the width; the header and front elevation give 85.5 mm. Confirm the width of the supplied revision before fixing panel spacing.

Product overview

Use NDR-480 where the panel needs one DC voltage. For example, NDR-480-24 provides 24 V at 0–20 A, while NDR-480-48 provides 48 V at 0–10 A. Compare the actual load profile, not the suffix alone.

Design features

CiriWhat to check
Output selection24 V or 48 V; choose one version for the required DC rail.
Input and restartAt cold start the input draws 20 A at 115 VAC; 35 A at 230 VAC. This transient is not available to the DC load.
Cabinet environment−10 to +50 °C. Check the intended load at the actual ambient temperature.

The dimension table gives 85 mm for the width; the header and front elevation give 85.5 mm. Confirm the width of the supplied revision before fixing panel spacing.

Installation & applications

Pemeriksaan pemasangan

Reserve space on the rail for NDR-480.

Reserve space on the rail

The sheet lists 85 / 85.5 × 125.2 × 128.5 mm. Check terminal access and cable bends separately; the enclosure dimension is not an installation clearance.

Identify the terminal blocks for NDR-480.

Identify the terminal blocks

TB1: 1 = FG; 2 = AC/N or DC −; 3 = AC/L or DC +. TB2: 4 and 5 = −V; 6 and 7 = +V. Verify the markings on the unit before connecting power.

Check cabinet temperature for NDR-480.

Check cabinet temperature

−10 to +50 °C. Check the air temperature at the supply under the intended cabinet load. The temperature interval alone does not rate full output at its upper limit.

Allow for input inrush for NDR-480.

Allow for input inrush

The sheet gives 20 A at 115 VAC; 35 A at 230 VAC. Compare the applicable input condition with upstream protection; these are not DC load-current ratings.

Application examples

A round weighing dial hangs between the red chain block and the lower lifting hook.

Reading a suspended load

The pointer can be hard to read from below. A fixed 24 VDC task light can illuminate the dial without adding equipment to the hook. Size NDR-480-24 (0–20 A) for the lighting branch only; the mechanical scale and hoist are not DC loads in this example.

Photo: Audrius Meskauskas ( Audriusa ) · Crane weighting device.jpg · CC BY-SA 3.0 · Resized / WebP.
Narrow strips of fruit stickers unwind through parallel applicator heads above the packing line.

Applying fruit labels

A label-gap sensor can tell the controller when the next sticker reaches the peel point. If the sensor and input module accept 24 VDC, compare their combined demand with NDR-480-24 (0–20 A); size the feed drives separately.

Photo: Apple and Pear Australia Ltd · DSC_3764 Apple labelling machine in Batlow · CC BY 2.0 · Converted to WebP.
Printed foil passes from a blue-flanged reel over horizontal guide rollers; black registration marks run along its edge.

Keeping printed sachets in register

A contrast sensor can read each black edge mark so the sealer lines up with the printed sachet. Check that the reader and its input module accept 24 VDC before selecting NDR-480-24 (0–20 A). The sealing heaters and roller drive are separate loads.

Photo: Simon Berry (ColaLife) · Our foil going through the ORS packaging machine · CC BY-SA 2.0 · Resized / WebP.
Yellow quayside crane booms extend above rows of containers aboard a berthed ship.

Tracking a quay-crane trolley

A trolley-position encoder can report where the spreader is along the boom to a fixed control cabinet. For a 24 VDC encoder interface, check input current and cable drop against NDR-480-24 (0–20 A). This is a signal circuit, not the hoist or travel motor supply.

Photo: Ivan Mlinaric · Loading of a ship in Barcelona port · CC BY 2.0 · Converted to WebP.

These photographs show equipment in its working environment, not verified WEHO installations. The DC loads described are selection examples; check the actual component ratings.

Soalan-soalan yang sering ditanya

Which outputs are available?

The sheet lists 24 V or 48 V. Select the suffix that matches the load; these are separate output versions.

What current does the 24 V version supply?

NDR-480-24 is listed at 0–20 A. Include all loads that operate together; check startup demand separately.

What input range should I specify?

The NDR-480 sheet lists 85–264 VAC at 47–63 Hz, or 120–370 VDC. State which supply will be present at the panel.

What happens after a fault?

105–150%: output cutoff; automatic recovery. Overvoltage: 120–140%: output shuts down. Reapply power to recover.

How should I check cabinet fit?

The sheet lists 85 / 85.5 × 125.2 × 128.5 mm. The dimension table gives 85 mm for the width; the header and front elevation give 85.5 mm. Confirm the width of the supplied revision before fixing panel spacing.

What information is useful for a quotation?

Give the full suffix (for example, NDR-480-24), input source, running and startup current, cabinet temperature, quantity and destination.

Temperature derating

The NDR-480 company datasheet specifies a working temperature of −10 to +50 °C. It does not give a load-versus-temperature curve for these output versions. Do not treat the upper ambient limit as a full-load rating.

For a continuous-duty installation, state the selected output, maximum cabinet temperature, mounting position and expected load when requesting a confirmed operating point.

Send Inquiry

Tell us how many units you need and where they will be delivered.

NDR-480-24 sample, oblique view.
NDR-480-24 · photographed sample
Selected model
NDR-480-24NDR-480-48
DC output
24 V · 0–20 A48 V · 0–10 A

Apakah produk bekalan kuasa terbaik untuk perniagaan anda?

Meningkatkan perniagaan anda dengan produk bekalan kuasa berkualiti WEHO.

Tanya pakar