Convert receiver voltage into field strength using the correct antenna factor and the losses and gains of the actual measurement path. Before adding corrections, establish whether the instrument's displayed result already includes them.
- Preserve the reference plane and units of the raw reading.
- Add path losses and subtract external gain once.
- Match antenna-factor type and calibration conditions.
- Keep conversion separate from spatial search and detector selection.

1. Identify which quantity the report displays
A buyer reviewing an equipment emission result can encounter a receiver reading in dBµV and a reported field in dBµV/m. Those are different quantities. The conversion requires the measurement antenna and path information, not a simple change to the axis label or a comparison against a limit in incompatible units.
The WEHO NDR-120-24 product reference identifies one source in an equipment context. The following measurement-chain example does not establish that supply's emissions or certification. Ask for exact-model evidence while reviewing the complete equipment's antenna, receiver and correction record independently.
Tektronix's EMI pre-compliance note explicitly relates receiver voltage, antenna factor, cable loss and external preamplifier gain to a field result. Its software can perform this calculation automatically when the accessory information is configured. That makes correction-state traceability essential before any manual recalculation.
2. Write the reference-plane equation
For an electric-field measurement with the declared antenna factor, a useful logarithmic chain is E = Vreceiver + AF + Lcable + Lother − Gexternal. E is in dBµV/m, Vreceiver in dBµV, AF in dB/m and the path gains or losses in dB. Define the included path before applying the equation.
Antenna factor relates the antenna-terminal voltage to the relevant incident field under its calibration conditions. Cable loss reverses attenuation between that plane and the receiver. An external preamplifier increases the receiver voltage, so its gain is subtracted when recovering the corresponding field value. Additional attenuation must also be included if present.
The official CISPR 16-2-3 overview identifies the radiated-disturbance measurement framework and separate uncertainty references. This arithmetic worksheet does not supply the complete applicable method, site qualification, uncertainty budget or product limit. Those remain part of the actual laboratory decision.
| Quantidade | Typical record unit | Role in this chain | Check before use |
|---|---|---|---|
| Receiver voltage | dBµV | Starting observation | Raw or already corrected? |
| Electric antenna factor | dB/m | Add to recover field | Correct antenna and frequency? |
| Cable/attenuator loss | dB | Add path attenuation | Included elsewhere already? |
| External preamplifier gain | dB | Subtract external gain | Correct gain state and reference planes? |
A label such as “antenna correction” is insufficient when the file may contain a composite factor. Determine whether the saved values represent the antenna alone, antenna plus cable or a complete path. A mathematically correct sum of incorrectly interpreted files still produces an invalid field estimate.
3. Recalculate a hypothetical correction chain
Assume an invented raw receiver reading of 35 dBµV at one frequency. Assume the applicable electric antenna factor is 18 dB/m, cable loss is 2 dB and external preamplifier gain is 20 dB. Assume no other attenuator or path correction and no compression or mismatch correction in this simplified example.
The converted electric field is 35 + 18 + 2 − 20 = 35 dBµV/m. The net numerical correction is zero in this chosen example, but the physical quantity and unit still change. Equal numbers do not mean receiver voltage and electric field are interchangeable.
Converting the field result to linear units gives 10^(35/20) ≈ 56.23 µV/m. The raw 35 dBµV receiver voltage separately corresponds to 56.23 µV at the receiver reference plane. Their numerical equality follows from the invented net-zero factor, not from a general relationship between volts and volts per metre.
Swipe horizontally on a small screen, or open the full-size diagram.
If the 20 dB external gain were omitted, the calculation would produce 55 dBµV/m. That corresponds to approximately 562.34 µV/m, ten times the correctly converted example field amplitude. The error is a factor of ten in field amplitude, not a statement about radiated power or the equipment's actual emission.
Now suppose the receiver instead displays an already corrected 35 dBµV/m. Adding the 18 dB/m antenna factor again would produce a numerical 53 dBµV/m claim, an 18 dB overstatement. The safe arithmetic is to retain the displayed corrected result and its configuration, or reconstruct from genuinely raw data once.
| Invented processing | Calculation | Reported field | Disposition |
|---|---|---|---|
| Complete raw-data chain | 35 + 18 + 2 − 20 | 35 dBµV/m | Correct under declared assumptions |
| External gain omitted | 35 + 18 + 2 | 55 dBµV/m | 20 dB error |
| Antenna factor added twice | Corrected 35 + 18 | 53 dBµV/m | 18 dB duplicate correction |
| Raw voltage relabeled | No documented chain | Unsupported field claim | Numerical coincidence is insufficient |
4. Check active antennas and composite factors
The applicable factor must describe the antenna actually used. ISED's RSS-Gen informative antenna-factor annex gives an instructive active-loop example: its antenna factor already includes the built-in preamplifier. The separate external-gain term concerns an additional external preamplifier, not that internal gain again.
That annex has a defined radio-apparatus and low-frequency loop context. It does not make its specific magnetic/electric conversion rules universally applicable to every industrial measurement. Its relevant lesson here is to understand the calibrated reference plane and included functions before composing a measurement chain.
An electric antenna factor and a magnetic antenna factor also have different dimensions. Do not substitute one because the calibration file has similar-looking numbers. Identify the measured field quantity, antenna type, frequency and required limit quantity, then apply the actual method's conversion conditions where a conversion is justified.
Path factors vary with frequency. A gain specified at one frequency cannot automatically correct an entire emission sweep. Retain calibration identifiers, the frequency-dependent tables and the software interpolation or correction settings used to produce the result. Preserve an expired or changed calibration as a review issue rather than silently replacing its file.

5. Verify one reproducible correction chain
- Identify the display state. Record units, correction enablement and raw-data availability. Verify whether the selected observation is receiver voltage or an already converted field value.
- Map the physical path. Record antenna, cables, attenuators and external amplifier states. Verify reference planes against the actual connected equipment.
- Match the factor files. Record calibration identifiers, frequency and included functions. Verify that no gain or loss appears in two different composite factors.
- Recalculate a point. Record the raw value and every signed term. Verify unit consistency and reproduce the displayed result within the relevant processing precision.
- Release the bounded result. Record the corrected field, method and uncertainty information. Verify the required detector and spatial-search evidence separately before making the equipment acceptance decision.
Changing a cable or amplifier after calibration mapping changes the measurement chain. Review that change even when the receiver model and antenna remain the same. A saved setup file is useful only if its accessory identities and gain states still match the physical arrangement used for the measurement.
6. Request the component and report evidence
For an NDR-120-24 equipment review, provide the equipment configuration, intended market and relevant emission report. Include raw/corrected units and the factor-chain record when a reported value is unclear. Request matching product documentation while the EMC laboratory retains responsibility for the complete equipment measurement and applicable acceptance decision.
Perguntas frequentes
Can a receiver value in dBµV be compared directly with a dBµV/m limit?
No. Receiver voltage and field strength are different quantities. Establish the appropriate antenna and path conversion before comparing a field result with a compatible limit.
Should external preamplifier gain be added to the receiver reading?
No. In the declared reconstruction equation, external gain is subtracted because it increased the observed receiver voltage. Check whether the software or a composite factor already includes that gain.
Does an active antenna need its built-in gain corrected separately?
Not necessarily. Its calibrated factor may already include built-in amplification. Use the actual calibration definition instead of applying an additional gain correction by assumption.
Does correct field conversion establish equipment compliance?