S-500W series normal single switching power supply

WEHO S-500 is a single-output switching power supply with 12V, 24V, 36V and 48V variants. Its output-specific current, noise and efficiency rows support selection of compatible recipe-entry and status electronics in equipment such as an automated screwdriving cell. A defined body-size row and separate protection recovery actions give the equipment team concrete integration questions to resolve. Specify the required suffix, real load and input configuration when requesting a quotation; machinery drives and protective functions are outside this proposed role.

หากคุณมีคำถามใด ๆ โปรดอย่าลังเลที่จะติดต่อเราได้ที่ อีเมล: [email protected]

ข้อมูลจำเพาะ S-500-12 S-500-24 S-500-36 S-500-48
แรงดันขาออก DC, กระแส 12V 0 ~ 40A 24V 0 ~ 20A 36V 0 ~ 14A 48V 0 ~ 10A
คลื่นและเสียง 100mVp-p 150mVp-p 150mVp-p 150mVp-p
ความเสถียรของสายไฟขาเข้า ±0.5% ±0.5% ±0.5% ±0.5%
เสถียรภาพในการโหลด ±0.5% ±0.5% ±0.5% ±0.5%
ประสิทธิภาพ 83% 85% 86% 87%
ช่วงที่สามารถปรับได้สำหรับแรงดันไฟฟ้ากระแสตรง ±10% ±10% ±10% ±10%
ช่วงแรงดันไฟฟ้าขาเข้า 90 ~ 132VAC/180 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz
กระแสกระแทก เริ่มเย็นในปัจจุบัน 25A / 115VAC 50A / 230VAC
การป้องกันการโอเวอร์โหลด 105% ~ 300% cut off the output, automatic recovery
การป้องกันแรงดันไฟฟ้าเกิน 115% ~ 140% shut down O/P voltage, re-power on to recover
ตั้งค่า เพิ่มขึ้น และคงสถานะการออนไลน์ไว้ 800ms, 20ms, 36ms/230VAC at full load
ทนต่อแรงดันไฟฟ้า I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute
ความต้านทานการแยก I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ
อุณหภูมิในการทำงาน -10°C ~ +50°C
มิติ 238 × 124 × 65mm
น้ำหนัก 1.35kg
การบรรจุ 44 × 26 × 27CM/12PCS/16.2kg

Why Choose S-500

Distinguish the selected output on the bill of materials

The S-500-12 column specifies 12V at 0 ~ 40A. The same document also includes higher-voltage alternatives, so a series-only purchase description is insufficient. Tie the exact S-500 suffix to the board input specification and actual demand, rather than treating the nominal power class as a common output rating.

Make mains selection an explicit build item

AC input is 90 ~ 132VAC or 180 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. This gives equipment builders two documented AC bands and a separately printed DC range to review. Assign input configuration and delivered-unit checks to the build specification; a switch-selected input must not be described as automatic ranging.

Coordinate packaging with the electrical-bay design

The dimension row is 238 × 124 × 65mm and the weight row is 1.35kg. The stated body size and mass help establish the cabinet allocation and support requirement before detailed layout. Review fixing points, service access and the complete enclosure environment independently; these values do not qualify an existing mounting pattern or a closed thermal design.

Specify a controlled final voltage setting

DC voltage adjustment is ± 10% for each listed output. The adjustment range provides a documented basis for a final board-supply setting when the load specification permits it. Confirm the setting under the intended conditions and do not infer extra current or continuous power from moving the adjustment.

S-500 Features and Selection Value

Check output-specific regulation

Inlet wire stability is ± 0.5% for each listed output. Load stability is S-500-12: ± 0.5%; S-500-24: ± 0.5%; S-500-36: ± 0.5%; S-500-48: ± 0.5%. The table gives a common inlet and load-stability figure, while voltage trim is a different row. Regulation and voltage adjustment are separate checks for the receiving electronics.

Match the printed noise limit to the electronics

Wave-and-noise values are S-500-12: 100mVp-p; S-500-24: 150mVp-p; S-500-36: 150mVp-p; S-500-48: 150mVp-p. A lower printed value belongs to the first output column, not the entire series. Verify the actual board noise tolerance and installation rather than generalizing one column into a precision-supply claim.

Use the selected output efficiency

Listed efficiencies are S-500-12: 83%; S-500-24: 85%; S-500-36: 86%; S-500-48: 87%. Column-specific efficiency supports an output-aware thermal review, not a guaranteed result at every load. The enclosure designer still needs the real dissipation and ventilation assessment.

Distinguish fault recovery actions

Overload protection is 105% ~ 300%; it cuts off the output with automatic recovery. Overvoltage protection is 115% ~ 140%; it shuts down the output voltage and requires re-powering to recover. Document both recovery paths in the equipment fault review. The broad overload interval is not a selectable constant-current operating range or permission for repeated process overload.

Typical Service Conditions

Control enclosure vibration at a turret punch

The printed working-temperature range is -10°C ~ +50°C. A sheet-metal turret punch may assess a selected S-500 output for compatible job-interface and maintenance-status electronics. Verify secure mounting, supported conductors and local temperature under the intended vibration exposure. Punch drives, sheet positioning and protective controls remain separately engineered; the proposed DC role is limited to the compatible electronics.

Keep cut-to-length electronics clear of swarf

An extrusion cut-to-length station may evaluate an exact S-500 suffix for compatible length-recipe and communication boards. Protect the electrical bay from swarf and coolant and confirm the delivered input selector setting before energizing. Feed and saw drives, dimensional sensing and machine safety require independent power and validation.

Preserve a dry bay beside bottle inspection

At a bottle-cap inspection tunnel, a qualified S-500 output may supply compatible recipe-interface and local status electronics. Keep wash fluids and condensation out of the electrical compartment, and confirm the real operating temperature and reset sequence. Camera power, illumination, reject actuation and inspection accuracy are separate requirements; the concept is not washdown or food-contact approval.

Plan recovery at a part-marking station

An industrial part-marking station may assess an accepted S-500 variant for compatible job-selection and diagnostic boards. Check the load during startup and after interruptions, and coordinate any supply recovery with the equipment reset logic. The marking source, part motion and protective interlocks remain independent; automatic electrical recovery is not permission for automatic machine restart.

Potential S-500 Equipment Applications

Automated screwdriving cell

An automated screwdriving cell may consider an exact S-500 suffix for compatible recipe-entry and result-display boards. Confirm board voltage, transient demand and the protection plan for its electronic branches. Screwdriver drives, fastener feeders, torque measurement and safety functions need their own qualification rather than a series-level wattage assumption.

Resin-metering skid

A resin-metering skid may evaluate a selected S-500 output for compatible batch-entry and communication boards in a segregated dry section. Check compatibility with the actual electronics and the enclosure environment, including cleaning exposure. Pump drives, resin heaters and calibrated proportioning are separately engineered; no fluid-handling or hazardous-area suitability is implied.

Fabric-inspection frame

A fabric-inspection frame may assess a qualified S-500 variant for compatible job-record and status electronics. Determine the electronic load and verify the chosen output against its allowed supply noise and startup behavior. Fabric transport, inspection lighting and camera performance remain separate; lint control and actual electrical-bay temperature must be engineered.

Pallet stretch-wrapper

A pallet stretch-wrapper may evaluate an exact S-500 output for compatible wrap-recipe and diagnostic boards. Confirm the input source, branch protection and electronic restart behavior in the installed cabinet. Turntable and film-carriage drives, load containment and protective circuits remain independently selected and validated.

S-500 Technical FAQs

Which output variants and current ranges are listed for S-500?

S-500-12: 12V, 0 ~ 40A; S-500-24: 24V, 0 ~ 20A; S-500-36: 36V, 0 ~ 14A; S-500-48: 48V, 0 ~ 10A. The summary describes a single-output 500W series. Select one exact output rather than combining column maxima. The printed current range is not a separate continuous power rating, a constant-current function or proof of load-free behavior. The final continuous load, startup margin and thermal conditions require a variant-specific engineering decision; multiplying voltage and current does not replace that decision.

What input ranges and selection method are specified for S-500?

AC input is 90 ~ 132VAC or 180 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. Verify the actual input source and the delivered selector setting before energizing. The AC bands are switch-selected, not a continuous automatic input range. A printed DC range alone does not approve DC wiring, source protection or a battery installation.

How should the S-500 cold-start current figures be interpreted?

Cold-start current is 25A at 115VAC and 50A at 230VAC. These are input inrush figures at the two printed AC conditions, not the normal input current or the available DC output current. Check upstream switching and protection against the actual equipment startup sequence; no new breaker or fuse rating is inferred.

What setup, rise and hold-up times are printed for S-500?

Setup, rise and hold-up times are 800ms, 20ms, 36ms, respectively, at 230VAC at full load. The values follow the printed label order and belong to that stated input/load condition. Hold-up time is not stored-energy backup, a UPS function or proof that the connected controller will ride through every interruption. The timing-only full-load condition does not approve full-load operation throughout the temperature range.

What wave-and-noise value applies to each S-500 output?

S-500-12: 100mVp-p; S-500-24: 150mVp-p; S-500-36: 150mVp-p; S-500-48: 150mVp-p. Apply the value specified for the selected output. The sheet does not turn these figures into a guarantee for every cable, load waveform or measurement setup. Check the receiving electronics and the complete grounding and wiring arrangement before accepting a noise-sensitive load.

How do S-500 regulation and voltage adjustment differ?

Inlet wire stability is ± 0.5% for all listed outputs. Load stability is S-500-12: ± 0.5%; S-500-24: ± 0.5%; S-500-36: ± 0.5%; S-500-48: ± 0.5%. DC voltage adjustment is ± 10% for each listed output. Inlet regulation, load regulation and output adjustment describe different selection questions. Do not reinterpret a regulation figure as voltage accuracy, or use the adjustment range as permission to exceed the receiving board input limit or the selected variant load boundary.

Which efficiency figure belongs to each S-500 variant?

S-500-12: 83%; S-500-24: 85%; S-500-36: 86%; S-500-48: 87%. Each percentage belongs to its own output column. The sheet does not state a common efficiency for every variant or all operating points. Use the actual equipment operating conditions for the thermal design rather than selecting a column maximum for the entire series.

What overload action and recovery behavior are specified for S-500?

Overload protection is 105% ~ 300%; it cuts off the output with automatic recovery. Confirm this broad printed interval with the manufacturer before protection coordination. The printed percentage interval is a protection threshold range, not a normal constant-current control range. Coordinate the electronic branch protection and load-reset behavior so that automatic supply recovery cannot initiate an unintended machine cycle.

What overvoltage action and recovery behavior are specified for S-500?

Overvoltage protection is 115% ~ 140%; it shuts down the output voltage and requires re-powering to recover. The recovery action differs from the overload row. Resolve the cause of the event and the equipment restart procedure before re-energizing; this is not an automatic overvoltage-reset claim, a redundant protective system or a safety-rated shutdown.

What temperature and moisture boundaries are documented for S-500?

The printed working-temperature range is -10°C ~ +50°C. Storage temperature, working humidity and storage humidity are not specified on this sheet. The sheet provides no load-versus-temperature curve or full-load approval across that entire range. Establish the actual electrical-bay temperature, airflow and electronic demand for the installed equipment. Confirm storage and moisture limits separately with the manufacturer.

What dimensions and terminal legend are printed for S-500?

The dimension row is 238 × 124 × 65mm and the weight row is 1.35kg. The drawing assigns AC input to pins 1 and 2, GND to pin 3, DC output -V to pins 4, 5 and 6, and DC output +V to pins 7, 8 and 9. This is the generic source drawing legend, not a delivered-variant wiring instruction. Confirm the actual terminal order, ratings, conductor requirements, bonding, permitted links and fixing geometry on the selected unit before connection. No series/parallel interconnection, clearance or drop-in replacement fit is established.

What insulation tests are listed, and what approvals do they not establish for S-500?

Withstand values are I/P-O/P: 1.5kV, I/P-FG: 1.5kV and O/P-FG: 0.5kV for 1minute, without a printed AC/DC qualification. Isolation resistance is listed as 500VDC/100MΩ for I/P-O/P, I/P-FG and O/P-FG. These printed test entries are not a product certification, an ingress-protection rating or proof of system safety. PFC, an IP rating and certification scope are not documented on this sheet; any such procurement requirement needs separate exact-model evidence. No warranty term is inferred.

คำถามที่พบบ่อย

Q1: How do I choose the right S-500W switching power supply for my equipment?

Start by confirming the required DC output voltage and calculating the maximum current of all connected loads. The total load should remain within the rated capacity of the S-500W power supply, with additional margin for startup current and load fluctuations. Installation space, ventilation, and ambient temperature should also be considered.

Q2: What applications is the S-500W switching power supply suitable for?

The S-500W series can be used in industrial automation, machinery, control equipment, LED systems, communication equipment, testing devices, and other electronic systems that require a stable single DC output. The correct version should be selected according to the voltage and current requirements of the equipment.

Q3: How much power margin should I leave when using a 500W power supply?

It is generally better to avoid operating a switching power supply continuously at 100% of its rated power. A reasonable power margin helps accommodate startup current, temporary load increases, and higher ambient temperatures. The exact margin depends on the application, duty cycle, and load characteristics.

Q4: What is the difference between a 500W switching power supply and a linear power supply?

A switching power supply normally offers higher efficiency, smaller size, and lower heat generation than a linear power supply at the same output power. For 500W industrial applications, switching power supplies are usually more practical where cabinet space, energy efficiency, and power density are important.

Q5: What information should I provide when requesting a quote for the S-500W series?

For faster model selection, provide the required output voltage, load current, application, operating environment, input voltage, expected quantity, and any special installation requirements. These details help determine whether the S-500W series is suitable for the project.