S-50W series normal single switching power supply

WEHO S-50 is a 50W-designated single-output family for compatible equipment-control, display and interface electronics, with separate 5V, 12V, 15V and 24V options in a 159×98×38mm enclosure. Input is 90~132VAC/180~264VAC by switch, with 254~370VDC also specified. The 12V and 15V models list 0~4.2A and 0~3.4A. Assess the selected output’s startup demand, ripple and the 20ms hold-up entry at 230VAC and full load for the actual assembly.

หากคุณมีคำถามใด ๆ โปรดอย่าลังเลที่จะติดต่อเราได้ที่ อีเมล: [email protected]

ข้อมูลจำเพาะ S-50-5 S-50-12 S-50-15 S-50-24
แรงดันขาออก DC, กระแส 5V 0~10A 12V 0~4.2A 15V0~3.4A 24V0~2.1A
คลื่นและเสียง 75mVp-p 100mVp-p 100mVp-p 100mVp-p
ความเสถียรของสายไฟขาเข้า ±0.5% ±0.5% ±0.5% ±0.5%
เสถียรภาพในการโหลด ±1% ±0.5% ±0.5% ±0.5%
ประสิทธิภาพ 71% 78% 78% 82%
ช่วงที่สามารถปรับได้สำหรับแรงดันไฟฟ้ากระแสตรง ±10% ±10% ±10% ±10%
ช่วงแรงดันไฟฟ้าขาเข้า 90~132VAC/180~264VAC by switch 254~370VDC 47~63Hz
กระแสกระแทก Cold start current 18A/115VAC 36A/230VAC
การป้องกันการโอเวอร์โหลด 105%~150%ตัดเอาต์พุต การกู้คืนอัตโนมัติ
การป้องกันแรงดันไฟฟ้าเกิน 115% ~ 135% shut down O/P voltage, re-power on to recover
ตั้งค่า เพิ่มขึ้น และคงสถานะการออนไลน์ไว้ 200ms,100ms,20ms/230VAC ที่โหลดเต็ม
ทนต่อแรงดันไฟฟ้า I/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1 นาที
ความต้านทานการแยก I/P-O/PI/P-FG O/P-FG:500VDC/100MΩ
อุณหภูมิในการทำงาน -10°C~+50°C
มิติ 159×98×38มม
น้ำหนัก 0.5กก
การบรรจุ 34×32×24ซม./30ชิ้น/15กก

Why Choose the S-50?

Use the exact 12V or 15V output column

S-50-12 lists 12V 0~4.2A and S-50-15 lists 15V 0~3.4A. The 50W family designation and these current-range endpoints do not define the complete continuous operating envelope. Confirm the complete load envelope of the actual electronic assembly.

Coordinate interruption tolerance with the 20ms entry

Setup, rise and hold-up are 200ms, 100ms and 20ms at 230VAC and full load. Use this stated condition when assessing board reset, data retention and response to real power interruptions; the entry does not guarantee uninterrupted operation.

Assess noise and efficiency by output voltage

S-50-5 lists 75mVp-p ripple and 71% efficiency, while the 24V version lists 100mVp-p and 82%. The other variants have their own entries. Evaluate the exact version’s heat and board tolerance; the most favourable figure is not a universal family guarantee.

Plan installation geometry and input selection

The 159×98×38mm outline, terminal arrangement and manual AC selector all belong in an equipment-integration review. Check actual mounting, protected terminal access and ventilation. Shared dimensions with a different wattage model do not prove electrical interchangeability.

S-50 Features

Four alternative single-output options

The table lists S-50-5 at 5V 0~10A, S-50-12 at 12V 0~4.2A, S-50-15 at 15V 0~3.4A and S-50-24 at 24V 0~2.1A. These are separate ordered variants, not four outputs on one unit.

Adjustment and regulation tied to the model

DC-voltage adjustment is ±10% and line stability is ±0.5% across the four columns. Load stability is ±1% at 5V and ±0.5% at 12V, 15V and 24V. Adjustment is not evidence of regulated-current output or a programmable source.

Cold-start current at two line conditions

Cold-start current is 18A at 115VAC and 36A at 230VAC. Assess upstream switching at the matching input condition. These figures are not continuous input-current ratings or a circuit-breaker selection, and they do not approve simultaneous startup of an arbitrary number of supplies.

Separate automatic and power-cycle recovery

Overload at 105%~150% cuts off output with automatic recovery. Overvoltage at 115%~135% shuts down output and requires re-powering. Design the connected equipment for each response and verify protection coordination; neither row establishes continuous fault duty.

Typical Service Conditions

Keep a vial-sorter interface cabinet isolated from spills

A vial-sorter interface cabinet may assess a selected S-50 for compatible local control and indication boards. Keep liquid handling and cleaning fluid outside the dry electrical section. Sorter drives, reject valves and process suitability remain separately qualified functions.

Assess load steps in a stencil-alignment console

A stencil-alignment console needs measurement of actual electronic demand during boot and operating transitions. Use the exact accepted voltage and verify ripple at the load. Alignment drives, optical sources and positional accuracy are not established by the S-50 supply choice.

Manage paper dust around a sheet-feeder control bay

A sheet-feeder control bay should protect the supply from paper dust and maintain verified cooling paths. The printed temperature range is not a full-load thermal envelope. Feeder motors, brakes and safety interlocks require independent power and control design.

Segregate signal returns in a displacement-gauge rack

A displacement-gauge rack needs controlled signal routing, board voltage compatibility and validated reference connections. Consider S-50 only for compatible local electronics. Probe excitation, measurement isolation and dimensional calibration are independent requirements.

Potential S-50 Applications

Rotary-encoder gateway cabinet

Evaluate an exact S-50 variant for compatible gateway and interface electronics after checking their startup and continuous demand. Encoder supply requirements, isolation and communication integrity need their own validation. The unit does not supply the motion drive or establish machine position safety.

Industrial batch-weigh display

A batch-weigh display may assess a qualified output for accepted logic, indication and communication electronics. Verify noise tolerance and interruption behavior. Load-cell excitation, weighing accuracy, feeder motors and material gates remain separately engineered functions.

Pneumatic tool-cycle recorder

Consider a selected S-50 output for compatible recorder and interface boards in a protected enclosure. Check the actual board requirements and fault restart response. Air valves, tool actuation and any operator-protection system require separately qualified design.

Coil-inspection operator station

A coil-inspection operator station may evaluate an accepted S-50 version for compatible local interface electronics. Confirm supply voltage, thermal conditions and cable routing. Test excitation, high-energy inspection equipment and defect-detection performance are outside this proposed supply role.

S-50 Technical FAQs

Which exact output models and current ranges are listed?

S-50-5 lists 5V 0~10A; S-50-12 lists 12V 0~4.2A; S-50-15 lists 15V 0~3.4A; S-50-24 lists 24V 0~2.1A. They are alternative single-output models, not four simultaneous rails.

Does the 50W designation approve every continuous operating point?

The family designation and printed current ranges are separate entries. Do not calculate a replacement continuous wattage from their endpoints or assume maximum output at every input and temperature. Confirm the ordered suffix’s continuous and startup duty; the printed zero lower bounds do not independently establish minimum-load or no-load acceptance.

Is the AC input automatically selected?

The sheet states 90~132VAC/180~264VAC by switch, plus 254~370VDC and 47~63Hz. Select the correct AC band before energizing; this is not automatic range selection. Confirm separate DC-input connection instructions before DC use.

What does the voltage-adjustment entry establish?

Each model lists ±10% DC-voltage adjustment. It does not establish regulated-current output, dimming, arbitrary programmable operation or battery charging. Confirm the adjustment procedure, connected load voltage limits and accepted operating envelope before using a changed setting.

What ripple and line/load stability apply to each output?

S-50-5: 75mVp-p; S-50-12: 100mVp-p; S-50-15: 100mVp-p; S-50-24: 100mVp-p. All four list ±0.5% line stability; the 5V version lists ±1% load stability and the other outputs ±0.5%. No ripple measurement bandwidth or wiring method is specified by these entries.

Which efficiencies and cold-start values belong to this model?

Efficiencies in S-50-5, S-50-12, S-50-15, S-50-24 order are 71%, 78%, 78%, 82%. Cold-start current is 18A/115VAC and 36A/230VAC. Efficiency depends on the selected output; each cold-start value applies to its stated input voltage and is not a continuous input-current rating.

How does overload protection recover?

The overload entry is 105%~150%, cutting off the output with automatic recovery. This is not a continuous overload allowance or a replacement for cable and branch protection. Evaluate the connected electronics’ behavior during repeated power loss and recovery as part of the equipment design.

Does overvoltage shutdown recover automatically?

The overvoltage entry is 115%~135%, shutting down the output voltage and requiring re-powering to recover. Keep this separate from automatic overload recovery. Safe restart and downstream protection need their own equipment-level verification.

Which setup, rise and hold-up values and conditions are specified?

Setup, rise and hold-up are 200ms, 100ms and 20ms at 230VAC and full load. The stated input and full-load conditions apply to this timing entry. Full-load timing does not establish full load throughout the temperature range or identical response at every input and load.

What working temperature, dimensions and mass are listed?

The values are -10°C~+50°C, 159×98×38mm and 0.5kg. Check actual mounting, terminal access, service clearance and local thermal conditions. These entries do not provide an ingress rating, humidity specification or complete full-load derating curve.

What withstand and isolation-resistance entries are printed?

The withstand row lists I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute, without an AC/DC qualifier. Isolation resistance is listed as 500VDC/100MΩ for the named input/output/frame-ground pairs. These component test entries do not establish certification scope or finished-equipment approval.

What terminal order is shown, and can it be transferred between models?

The S-50 legend labels pins 1 and 2 as AC input, pin 3 as GND, pin 4 as DC output-V and pin 5 as DC output+V. Confirm the exact delivered unit, terminal markings and connection instructions before wiring, including a proposed DC-input application. Similar enclosures do not authorize transferring another model’s wiring.