RSP-320 PFC'li AC'den DC'ye Güç Kaynağı
RSP-320W is a single-output power supply with PFC for equipment needing a dedicated DC rail. Separate 12 V, 24 V, 36 V and 48 V versions, ±10% voltage trim and remote output on/off control support equipment integration. Its 30 mm body height helps with low-profile layouts. Share the complete voltage version, load profile and installation conditions for a selection review.
- Tanım
Özet
Single output:power 320W
Giriş voltajı: 90~264VAC,135~370VDC
Genel Şartname
| Spesifikasyon | RSP-320-12 | RSP-320-24 | RSP-320-36 | RSP-320-48 |
| DC çıkış voltajı, akım | 12V 0~26.7A | 24V 0~13.3A | 36V 0~8.9A | 48V 0~6.7A |
| Dalga ve gürültü | 150mVp-p | 200mVp-p | 220mVp-p | 240mVp-p |
| Hat düzenleme oranı | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Yük düzenleme oranı | ±1% | ±0,5% | ±0,5% | ±0,5% |
| Yeterlik | 91% | 92.5% | 93% | 94% |
| DC voltajı için ayarlanabilir aralık | ±10% | ±10% | ±10% | ±10% |
| Giriş voltajı aralığı | 90~264VAC,135~370VDC(300VAC dalgalanma girişine 5 saniye boyunca hasar görmeden dayanabilir)47-63Hz | |||
| AC giriş akımı | 4.0A/115V 2.0A/230VAC | |||
| Güç faktörü | PF≥0,99/115VAC,PF≥0,95/230VAC (Tam yüklü olduğunda) | |||
| Darbe akımı | Cold start current 40A/230VAC | |||
| Aşırı yük koruması | Overload protection is activated at 100%-125% of the rated output power. Protection method: Hiccup mode, automatically restores normal output after abnormal conditions are removed. | |||
| Aşırı gerilim koruması | Overvoltage protection is activated at 115%-135% of the rated output voltage. Protection method: Hiccup mode, automatically restores normal output after abnormal conditions are removed. | |||
| Aşırı sıcaklık koruması | 85℃±10℃ Protection method: Hiccup mode, automatically recovers after the temperature returns to normal. | |||
| Kurulum, yükselme, bekleme süresi | 800ms,50ms,16ms/230VAC(Tam yüklendiğinde) | |||
| Voltaja dayanmak | Input/output space(I/P~O/P):1.5KVAC input to ground(I/P~FG):1.5KVAC output to ground(O/P~FG):0.5KVAC | |||
| Yalıtım direnci | Giriş/çıkış (I/P~O/P), girişten toprağa (I/P~FG), çıkıştan toprağa (O/P~FG):100M Ohm/500VDC/25°C/70%RH | |||
| Çalışma sıcaklığı/nemi | -20℃~+60℃ 20%~90%RH, No condensation | |||
| Boyut | 215×115×30mm(L*W*H) | |||
| Ambalaj | 0.8kg/20pcs/17.5kg/0.003m³ | |||
Genel Boyut (mm)
Why Choose RSP-320W?
Choose one rail for compatible loads
A selected voltage version provides one DC output for loads that accept the same rail. Define their combined demand rather than treating the voltage options as simultaneous outputs.
Match the permitted load voltage
The documented ±10% voltage adjustment supports setting a compatible DC input during integration. Check the load's permitted range before selecting the setting.
Plan a low-profile installation
The stated 215 × 115 × 30 mm body gives the equipment designer a defined starting envelope. Reserve additional space for conductors, ventilation and service access.
Coordinate operational output control
Remote output on/off control provides a documented function for an equipment operating sequence. Confirm the interface before implementation and keep safety isolation and emergency stopping independent.
Özellikler
Single output with PFC
The original identifies RSP-320W as a single-output PFC power supply. The nominal voltage columns describe separate versions.
Defined input specifications
The listed AC input is 90–264 VAC at 47–63 Hz. A separate 135–370 VDC input range is documented.
Fan and airflow guidance
The original product illustration and mechanical drawing show a fan, and the drawing marks an airflow direction. Preserve that air path in the equipment layout.
Documented fault recovery
Overload and overvoltage protection use hiccup mode with automatic recovery after the abnormal condition is removed. Overtemperature protection uses hiccup mode with recovery after temperature returns to normal.
Typical Service Conditions
Review the selected version as one branch of the complete equipment design.
Voltage and load budget
Match the full voltage suffix to every connected load. Review combined operating demand and startup or switching peaks against the selected version's limits; protective recovery is not a normal operating strategy.
Airflow and service space
Keep the illustrated fan air path unobstructed and route conductors away from ventilation openings. Allow installation and maintenance space beyond the 215 × 115 × 30 mm body; no universal clearance value is specified.
Local temperature and humidity
The listed working conditions are −20 to +60 °C and 20–90% RH without condensation. Assess temperature at the supply location with the intended load. This range alone does not establish full-load operation at +60 °C.
Remote control and fault response
Confirm the remote output-control interface before integration. Review how the load responds to output interruption and recovery, and retain the equipment's independent isolation and protective measures.
Application Planning Examples
These are conditional DC branch concepts, not documented customer installations or approval of a complete machine. Match the actual load, environment and selected version before use.
Indoor registration kiosk electronics
Evaluate a voltage-matched branch for terminal electronics and local indicators in an indoor registration kiosk. Locks, door actuators and safety-related access functions are outside this proposed supply role.
PCB optical-inspection auxiliaries
Consider a compatible branch for an illumination controller and selected interface electronics at one inspection station. Camera timing, measurement performance and conveyor drives require separate equipment design.
Dispensing-cell interface electronics
Assess a matched DC branch for the operator interface, sensors and indicators of a dispensing cell. This concept does not include main motion drives, fluid pumps or heater power.
Modular exhibit message display
Evaluate one bank of voltage-matched message modules with their own required current control. Confirm combined demand and ventilation; the proposed branch is not direct bare-LED drive or power for an entire exhibition.
RSP-320W Technical FAQs
Which nominal voltage versions are documented for RSP-320W?
The listed alternatives are RSP-320-12, RSP-320-24, RSP-320-36 and RSP-320-48, corresponding to 12 V, 24 V, 36 V and 48 V.
Does one unit provide four independently controlled outputs?
No. Each selected version provides one main DC output. The four voltage columns are alternative versions, not separate channels in one unit.
What does the ±10% adjustment change?
It adjusts DC output voltage within the documented trim range. It does not establish user-adjustable current regulation or a digital programming function.
What AC and DC input ranges are listed?
The AC specification is 90–264 VAC at 47–63 Hz. The separately listed DC input range is 135–370 VDC; connection and protection must suit the actual source.
Does the 300 VAC statement extend the continuous input range?
No. The original limits that statement to a five-second surge input without damage. It is not a continuous 300 VAC operating specification.
What body dimensions are stated?
The stated body dimensions are 215 × 115 × 30 mm. They do not include the additional space needed for conductors, cooling airflow and maintenance access.
What remote-control function is documented?
Output on/off control is shown in the original. Confirm the exact interface before implementation; this operating function is not a substitute for safety isolation or emergency stopping.
What cooling information is established?
The original shows a fan and marks an airflow direction. It does not specify a temperature-based speed-control strategy, acoustic performance or a universal installation clearance.
How does overload protection recover?
The listed response is hiccup mode with automatic recovery after the abnormal condition is removed. Normal load demand must remain within the selected version's operating limits.
How does overvoltage protection recover?
The listed response is hiccup mode with automatic recovery after the abnormal condition is removed. Assess the fault and the connected equipment's response rather than relying on repeated protection cycles.
Does the working-temperature range guarantee full output at its upper limit?
No. The listed −20 to +60 °C range does not by itself establish full-load operation at +60 °C in a particular installation. Assess the local thermal conditions and intended demand.
What information supports an RSP-320W selection review?
Provide the complete voltage version, operating and peak demand, permitted output setting, input source, remote-control needs, equipment layout, airflow path and local environmental conditions.
İşletmeniz için en iyi Güç Kaynağı ürünleri nelerdir?
WEHO kalitesindeki güç kaynağı ürünleriyle işinizi güçlendirin.
Bir Uzmana Sorun
