S-400W series normal single switching power supply

WEHO S-400 is a single-output switching power supply with 5V, 12V, 24V and 48V variants. It provides a suffix-specific DC choice for compatible job-interface, display and communication electronics in equipment such as a label-inspection rewinder. The documented adjustment, regulation and protection rows help an equipment builder compare the electronic branch with its actual requirements. Select the exact output, input configuration and enclosure design before integration; request a quotation with the board voltage, current profile and operating environment.

اگر آپ کے کوئی سوالات ہیں تو، براہ کرم ہم سے رابطہ کرنے میں سنکوچ نہ کریں۔ ای میل: [email protected]

S-400 Series Single-Output Switching Power Supply

Select one of 4 single-output versions. Compare the current and ripple at the voltage your load needs.

Photo withheld: the S-400-24 nameplate reads 17 A; the specification sheet lists 16.5 A. Confirm the supplied revision before ordering. See the dimensioned drawing

Select output voltage
ماڈل
S-400-5S-400-12S-400-24S-400-48
DC output
5 V · 0–60 A12 V · 0–33 A24 V · 0–16.5 A48 V · 0–8.3 A
AC input
90–132 V AC / 180–264 V AC (by switch)
DC input
254–370 V DC
کارکردگی
73%74%81%83%
Dimensions (L × W × H)
215 × 115 × 50 mm

Specifications & models

ParameterS-400-5S-400-12S-400-24S-400-48
DC output voltage and current5 V · 0–60 A12 V · 0–33 A24 V · 0–16.5 A48 V · 0–8.3 A
کارکردگی73%74%81%83%
Ripple and noise100 mV p-p150 mV p-p150 mV p-p200 mV p-p
لائن ریگولیشن±0.5%±0.5%±0.5%±0.5%
لوڈ ریگولیشن±1%±0.5%±0.5%±0.5%
DC voltage adjustment±10%±10%±10%±10%
ان پٹ وولٹیج90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz
Cold-start inrush25 A at 115 V AC; 50 A at 230 V AC
اوورلوڈ تحفظ105–135%. Output shuts off; automatic recovery.
Overvoltage protection115–150%. Output shuts off; cycle input power to recover.
Setup / rise / hold-up200 / 50 / 20 ms at 230 V AC, full load
وولٹیج کا مقابلہ کریں۔Input–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
موصلیت مزاحمت100 MΩ at 500 V DC: input-output, input-FG, output-FG
آپریٹنگ درجہ حرارت-10 to 50 °C
Dimensions (L × W × H)215 × 115 × 50 mm
Unit weight1.1 kg
پیکنگ45.5 × 31.5 × 26 cm; 20 units/carton; 22 kg/carton
Output options
آؤٹ پٹCurrentکارکردگیلہر
5 V0–60 A73%100 mV p-p
12 V0–33 A74%150 mV p-p
24 V0–16.5 A81%150 mV p-p
48 V0–8.3 A83%200 mV p-p
Additional model specifications
S-400-5
لائن ریگولیشن±0.5%
لوڈ ریگولیشن±1%
DC voltage adjustment±10%
S-400-12
لائن ریگولیشن±0.5%
لوڈ ریگولیشن±0.5%
DC voltage adjustment±10%
S-400-24
لائن ریگولیشن±0.5%
لوڈ ریگولیشن±0.5%
DC voltage adjustment±10%
S-400-48
لائن ریگولیشن±0.5%
لوڈ ریگولیشن±0.5%
DC voltage adjustment±10%
Common specifications
ان پٹ وولٹیج90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz
Cold-start inrush25 A at 115 V AC; 50 A at 230 V AC
اوورلوڈ تحفظ105–135%. Output shuts off; automatic recovery.
Overvoltage protection115–150%. Output shuts off; cycle input power to recover.
Setup / rise / hold-up200 / 50 / 20 ms at 230 V AC, full load
وولٹیج کا مقابلہ کریں۔Input–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
موصلیت مزاحمت100 MΩ at 500 V DC: input-output, input-FG, output-FG
آپریٹنگ درجہ حرارت-10 to 50 °C
Dimensions (L × W × H)215 × 115 × 50 mm
Unit weight1.1 kg
پیکنگ45.5 × 31.5 × 26 cm; 20 units/carton; 22 kg/carton

Dimensions & technical notes

Mechanical dimensions

215 × 115 × 50 mm (L × W × H)

Wide face
S-400 wide face, dimensioned in millimetres
Narrow face
S-400 narrow face, dimensioned in millimetres

Dimensions in millimetres. The source groups the AC input pins. Check L and N on the unit; the legend does not identify them individually.

The 135 mm dimension spans the mounting-ear hole centres. It is not the 115 mm body width.

Product overview

S-400 is a single-output enclosed supply. The S-400-5 and S-400-48 are separate units, not two settings on the same unit. Select the AC band that matches the installation. The two bands are not one continuous input range.

Design features

فیچرWhat to check
Input selectionSelect the AC band that matches the installation. The two bands are not one continuous input range.
Timing at full load200 / 50 / 20 ms at 230 V AC, full load. Do not apply this test condition to an entire operating range.
Case and mountingThe 135 mm dimension is the distance between mounting-ear hole centres, not the 115 mm case width.

Installation & applications

Installation checks

Illustrative current budget: 4 tunnel light sections at 2.5 A each versus the 16.5 A listed limit.

Budget the tunnel light sections together

If 4 tunnel light sections each draw 2.5 A, their running load is 10 A. The S-400-24 lists 16.5 A at 24 V DC. Use the maximum input per section with all its lighting channels enabled. Check peak demand and available output at the installed temperature.

S-400 body plan, 215 by 115 mm, with 50 mm table height. The adjacent load is a separate access sketch.

Allow for the body and service access

The body measures 215 × 115 × 50 mm. The 135 mm mounting-hole span is not the body width. Provide service access with the tunnel cover open and the camera cables still in place.

Capture a cycle for the camera pair: paired camera inputs.

Check simultaneous camera start

Restore power to both cameras and monitor the rail at their inputs. Check that both are ready before the controller issues the first trigger.

Thermal check for the acquisition computer: full capture load.

Measure inside the acquisition cabinet

Capture continuously with the case closed and all installed cards active. Check air beside the supply and PC rather than relying on the room temperature.

Application examples

Clear bottles pass through a bright, diffuse inspection tunnel between conveyor rails.

Lighting a bottle inspection tunnel

A 24 V tunnel light illuminates bottle walls. Count all driver channels at full continuous brightness, not the conveyor motor.

Two opposing cameras face a machined fork clamped in a fixture.

Comparing both sides of a part

Two 12 V cameras image opposite faces of the clamped part. Allow for simultaneous start-up and check trigger timing separately.

Camera cables enter a frame-grabber card beside a material inspection line.

Capturing high-rate image streams

A 12 V industrial computer powers the frame grabber through its card slot. Size the computer input for boot and capture.

An inspection monitor highlights a chip in a ceramic rim above a sample and reject bin.

Reviewing rejected images

A 24 V monitor shows the chipped rim for review. Allow for maximum backlight; processing and conveying use separate feeds.

Match the selected S-400 output voltage and available current to each load.

AI-generated application illustrations, not customer installation photographs.

اکثر پوچھے جانے والے سوالات

Which outputs can I specify for S-400?

The standard sheet lists 5 V, 12 V, 24 V, 48 V. Order the full suffix for the required output; the selector compares different units.

Which input can I connect?

90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz. Select the AC band that matches the installation. The two bands are not one continuous input range.

What space should I allow?

The 135 mm dimension is the distance between mounting-ear hole centres, not the 115 mm case width.

What happens on overload?

105–135%. Output shuts off; automatic recovery.

Send Inquiry

Tell us how many units you need and where they will be delivered.

Photo withheld: the S-400-24 nameplate reads 17 A; the specification sheet lists 16.5 A. Confirm the supplied revision before ordering.

Selected model
S-400-5S-400-12S-400-24S-400-48
DC output
5 V · 0–60 A12 V · 0–33 A24 V · 0–16.5 A48 V · 0–8.3 A