Product Categories

LRS-450 Enclosed Switching Power Supply — 450W Class

The LRS-450 is a 450W-class single-output enclosed power supply with a fan-equipped 215 × 115 × 50 mm body. Choose the 12V, 24V, 36V or 48V output version. Select 95–132VAC or 180–264VAC using the input-range switch; the DC input range is 254–370VDC and the AC frequency range is 47–63Hz. Confirm the final rated output power for the selected version with the quotation. The working temperature range is -10°C to +50°C; confirm permissible loading for the installation.

Για τις λεπτομερείς προδιαγραφές του LRS, επικοινωνήστε με τους πωλητές της WEHO στο E-mail: [email protected]

LRS-450 representative shown

LRS-450 Enclosed Switching Power Supply

Single-output AC–DC supply with switch-selectable AC input.

Τάση εξόδου
Μοντέλο
LRS-450-12LRS-450-24LRS-450-36LRS-450-48
DC output
12 V · 0–37.5 A24 V · 0–18.7 A36 V · 0–12.5 A48 V · 0–9.4 A
AC input
95–132 V AC / 180–264 V AC (by switch)
DC input
254–370 V DC
Αποδοτικότητα
82%85%86%87%
Dimensions (L × W × H)
215 × 115 × 50 mm

In the inquiry form, enter model LRS-450-12LRS-450-24LRS-450-36LRS-450-48 with your requirements.

Specifications & models

ParameterLRS-450-12LRS-450-24LRS-450-36LRS-450-48
DC output voltage and current12V 0~37,5A24V 0~18,7A36V0~12,5A48V 0~9,4A
Εύρος τάσης εισόδου95–132VAC / 180–264VAC by switch; 254–370VDC; 47–63Hz
Διαστάσεις215×115×50mm
Αποδοτικότητα82%85%86%87%
Θερμοκρασία εργασίας-10℃~+50℃
Ripple & noise150mVp-P180mVp-P240mVp-P240mVp-P
Ρύθμιση γραμμής±0,5%
Ρύθμιση φορτίου±1%±0,5%±0,5%±0,5%
DC voltage adjustment±10%
Inrush currentΡεύμα ψυχρής εκκίνησης 35A/115VAC 65A/230VAC
Προστασία υπερφόρτωσης105%–150% cut off the output. Protection type: Hiccup mode; recovers automatically after the fault condition is removed.
Προστασία από υπέρτασηHiccup mode with automatic recovery after the fault condition is removed. Confirm the approved overvoltage threshold for the ordered version.
Overtemperature protectionTurn off the output; normal output is restored after the temperature returns to normal.
Timing (setup / rise / hold-up)1500ms,30ms/230VAC 2000ms,50ms/115VAC at full load. No separate hold-up time is specified.
Αντοχή στην τάσηI/P-O/P:1,5kV I/P-FG:1,5kV O/P-FG:0,5kV 1 λεπτό
Αντοχή μόνωσηςI/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH
Βάρος1kg
Συσκευασία45,5×31,5×26CM/20PCS/20kg
Output options
ΠαραγωγήΡεύμαΑποδοτικότηταΚυματισμός (mVp-p)
12 V0–37.5 A82%150
24 V0–18.7 A85%180
36 V0–12.5 A86%240
48 V0–9.4 A87%240
Ρύθμιση φορτίου
12 V±1%
24 V±0,5%
36 V±0,5%
48 V±0,5%
Common specifications
Εύρος τάσης εισόδου95–132VAC / 180–264VAC by switch; 254–370VDC; 47–63Hz
Διαστάσεις215×115×50mm
Θερμοκρασία εργασίας-10℃~+50℃
Ρύθμιση γραμμής±0,5%
DC voltage adjustment±10%
Inrush currentΡεύμα ψυχρής εκκίνησης 35A/115VAC 65A/230VAC
Προστασία υπερφόρτωσης105%–150% cut off the output. Protection type: Hiccup mode; recovers automatically after the fault condition is removed.
Προστασία από υπέρτασηHiccup mode with automatic recovery after the fault condition is removed. Confirm the approved overvoltage threshold for the ordered version.
Overtemperature protectionTurn off the output; normal output is restored after the temperature returns to normal.
Timing (setup / rise / hold-up)1500ms,30ms/230VAC 2000ms,50ms/115VAC at full load. No separate hold-up time is specified.
Αντοχή στην τάσηI/P-O/P:1,5kV I/P-FG:1,5kV O/P-FG:0,5kV 1 λεπτό
Αντοχή μόνωσηςI/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH
Βάρος1kg
Συσκευασία45,5×31,5×26CM/20PCS/20kg

Dimensions & derating

Mechanical dimensions

215 × 115 × 50 mm (L × W × H)

Wide face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.
Narrow face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Body width: 115 mm. Width including mounting ears: 135 mm. Dimensions in millimetres. Pin numbers correspond to the terminal strip on the wide face. Body dimensions and mounting-hole spacing are separate references.

Load derating

Apply these curves only within the WEHO stated operating range of -10 to +50 °C and the input limits in the specification table. Observe the horizontal mounting condition. A wider reference axis does not expand the WEHO rating.

Normalized load curve. Use only within the WEHO stated operating and input limits; no extrapolation.
Use the "Others" trace for the listed 12 V, 24 V, 36 V and 48 V outputs. The 5 V trace does not introduce an additional WEHO output option.
Normalized load curve. Use only within the WEHO stated operating and input limits; no extrapolation.
Permitted load versus AC input voltage at the shown frequency. Follow the input-selector setting. Use the WEHO output table for absolute current ratings.
View the functional block diagram Functional block diagram. The WEHO specification table governs output ratings, protection thresholds and recovery.

Functional stages are shown here; the specification table governs rated output, protection thresholds and recovery.

Product overview

For a 24 V control rail, the LRS-450-24 has a listed output range of 0–18.7 A. Compare that range with the combined demand of your controllers, sensors and interface modules, including devices that start together. When comparing the 36 V version with another supply, use the exact output table rather than the number in the series name. The loading chart’s “Others” trace applies to the four listed outputs; its 5 V trace is not a fifth orderable option.

Power rating: The title identifies LRS-450, but the datasheet summary states 500 W. Neither figure establishes a continuous power rating for every output. Confirm the ordered version’s rating with WEHO.

Design features

ΧαρακτηριστικόWhat to check
Output trimUse the listed ±10% adjustment only within the load’s input limits.
Enclosure fitConfirm the mounting dimensions and allow room for wiring bends, airflow and terminal access.
Overload recoveryThe output recovers after the overload condition is removed. Check how the equipment restarts.

Installation & applications

Installation checks

A closed instrument, a clipboard and a handheld meter on a workshop bench.

Match the supply to the load

Check the incoming supply against 95–132 V AC / 180–264 V AC (by switch). Add the starting currents of devices that energize together before selecting the output version.

A closed, vented equipment cabinet beside a clear service aisle and a wall grille.

Leave room for service

Confirm the body, mounting-hole positions and terminal access against the drawing before laying out the panel.

An environmental test chamber with a lit observation window and an instrument cart.

Check the installed temperature

The listed working range is -10 to +50 °C. Measure the air near the installed supply under sustained load. Use the applicable loading curve within its stated limits.

An empty roller conveyor behind a yellow barrier, with a closed equipment cabinet beside it.

Plan for power returning

When power returns, the controls may restart before the machine is ready. Check the host equipment’s restart sequence independently.

Application examples

Size the supply for the auxiliary electronics, not for the whole machine.

A freestanding illuminated lightbox outside a glass-fronted shop at dusk.

Retail signage

Power a sign timer or a compatible display controller. LED modules may need separate current regulation.

24 V option: LRS-450-24 · listed current 0–18.7 A.

Indoor parcel lockers with a touchscreen and a parcel in an open compartment.

Parcel lockers

Size the rail for sensors and the operator interface. Account separately for lock pickup current.

12 V option: LRS-450-12 · listed current 0–37.5 A.

A carton passes a bracket-mounted photoelectric sensor with an amber status light on a conveyor belt.

Carton packaging

Supply sensors and indicators at the forming station. Size drive and safety circuits separately.

24 V option: LRS-450-24 · listed current 0–18.7 A.

A circuit board clamped below an inspection camera, with an enlarged board view on a monitor.

Electronics test fixtures

Supply status indicators or trigger interfaces. Use a separate precision source when the test requires controlled excitation.

12 V option: LRS-450-12 · listed current 0–37.5 A.

AI illustrations for application planning; not installation photographs, wiring diagrams or mechanical references.

Frequently asked questions

Single-output versionsOutput voltage and current range12 V0–37.5 A24 V0–18.7 A36 V0–12.5 A48 V0–9.4 A
Choose one DC output per supply.
Which output voltages are available?

Choose one nominal output: 12 V, 24 V, 36 V, 48 V. Each voltage is a separate model.

Which input voltage should I specify?

The listed AC input is 95–132 V AC / 180–264 V AC (by switch); the DC input is 254–370 V DC. The gap between the two AC bands is not part of the specified input range.

How much current is listed for the 24 V model?

LRS-450-24 is listed at 0–18.7 A. Check the current at startup as well as in steady operation.

What does the series power designation mean?

The title identifies LRS-450, but the datasheet summary states 500 W. Neither figure establishes a continuous power rating for every output. Confirm the ordered version’s rating with WEHO.

What temperature range can I use?

The working range is -10 to +50 °C. Check the applicable input and mounting conditions on the loading curves.

How do I check the mounting space?

The listed body measures 215 × 115 × 50 mm. Check the drawing for mounting dimensions and allow additional room for wiring and airflow.

What inrush current is listed?

The cold-start input current is 35 A at 115 V AC, 65 A at 230 V AC. This is an input-side event, not the current available to the DC load.

What should I include in my quote request?

Include the exact model, quantity, input source, load profile and destination. Include the available mounting space if the enclosure is tight.

LRS-450 datasheet

Close
Download PDF
LRS-450 datasheet, page 1 of 2: Electrical specifications.
LRS-450 datasheet, page 2 of 2: Mechanical drawing and performance curves.

LRS-450 product photograph

LRS-450 representative product photograph

Wide face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Narrow face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Use the "Others" trace for the listed 12 V, 24 V, 36 V and 48 V outputs. The 5 V trace does not introduce an additional WEHO output option.

Normalized load curve. Use only within the WEHO stated operating and input limits; no extrapolation.

Permitted load versus AC input voltage at the shown frequency. Follow the input-selector setting. Use the WEHO output table for absolute current ratings.

Normalized load curve. Use only within the WEHO stated operating and input limits; no extrapolation.

Ποια είναι τα καλύτερα προϊόντα Power Supply για την επιχείρησή σας;

Ενισχύστε την επιχείρησή σας με ποιοτικά προϊόντα τροφοδοσίας WEHO.

Ρωτήστε έναν ειδικό
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.