Product Categories

LRS-350 Series 350W Single Output Enclosed Switching Power Supply (LRS-350-12 / LRS-350-24 / LRS-350-48)

The WEHO LRS-350 is a 350W-class, single-output AC-DC switching power supply for industrial control cabinets, LED signage and compact OEM equipment. Its 30mm-high enclosure helps preserve installation space, while 12V, 15V, 24V and 48V versions let you match the DC bus to the load. A manually selected 90-132VAC or 180-264VAC input supports different mains configurations. Combine the right output version with suitable ventilation to build a clear, space-conscious power layout.

Tell WEHO your DC voltage and load requirements.

Εάν έχετε οποιεσδήποτε ερωτήσεις, μη διστάσετε να επικοινωνήσετε μαζί μας στο E-mail: [email protected]

Προσδιορισμός LRS-350-12 LRS-350-15 LRS-350-24 LRS-350-48
DC τάση εξόδου, ρεύμα 12V 0~29A 15V 0~23,2A 24V 0~14,6A 48V 0~7,3A
Κύμα και θόρυβος 150mVp-P 150mVp-P 150mVp-P 200mVp-P
Σταθερότητα καλωδίου εισόδου ±0,5% ±0,5% ±0,5% ±0,5%
Σταθερότητα φορτίου ±0,5% ±0,5% ±0,5% ±0,5%
Αποδοτικότητα 85% 86% 88% 89%
Ρυθμιζόμενο εύρος για DCvoltage ±10% ±10% ±10% ±10%
Εύρος τάσης εισόδου 90–132VAC / 180–264VAC by switch; 240–370VDC; 47–63Hz
Ρεύμα κρούσης Ρεύμα ψυχρής εκκίνησης 60A/230VAC
Προστασία υπερφόρτωσης 110%~150% διακόπτει την έξοδο, αυτόματη ανάκτηση
Προστασία από υπέρταση Hiccup mode with automatic recovery after the fault condition is removed. Confirm the approved overvoltage threshold for the ordered version.
Ρύθμιση, άνοδος, διατήρηση χρόνου 1500ms,50ms/230VAC 1500ms,50ms/115VAC
Αντοχή στην τάση I/P-O/P:1,5kV I/P-FG:1,5kV O/P-FG:0,5kV 1 λεπτό
Αντοχή στην απομόνωση I/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃ /70%RH
Θερμοκρασία εργασίας -20℃~+70℃
Διάσταση 215×115×30 χιλιοστά
Βάρος 0,76 κιλά
Συσκευασία 37,5×25×26CM/20PCS/16kg

Download LRS-350 Datasheet (PDF)

Mechanical dimensions

LRS-350 — dimensions in millimetres
Body length215 mm
Body width115 mm
Body height30 mm
Width including mounting ears135 mm

The body dimensions and mounting-hole dimensions are different references. The vector drawing below retains the dimensions printed in the WEHO original.

On a small screen, swipe the drawing horizontally to inspect every dimension. No separate drawing image or script download is required.

Exact mechanical drawing from the WEHO original. Units: mm. Use the printed body, mounting and hole dimensions separately.

Load derating

Apply these model-specific curves only within the stated WEHO operating range of -20 to +70 °C and the input range in the specification table. A reference axis extending below that range does not extend the product rating. Follow the input-voltage and mounting-orientation labels shown on each curve.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus ambient temperature. Observe the separate input-voltage curves where shown.
Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus AC input voltage at the frequency shown. Use the correct input selector setting where applicable.
View the functional block diagram Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.

Overview

The WEHO LRS-350 is a 350W-class, single-output AC-DC switching power supply for industrial control cabinets, LED signage and compact OEM equipment. Its 30mm-high enclosure helps preserve installation space, while 12V, 15V, 24V and 48V versions let you match the DC bus to the load. A manually selected 90-132VAC or 180-264VAC input supports different mains configurations. The input specification also lists 240-370VDC; confirm the connections and selector setting for a DC-powered installation. Combine the right output version with suitable ventilation to build a clear, space-conscious power layout.

Why Choose LRS-350?

Fit power into compact equipment

The 30mm body height helps keep the power section compact in shallow equipment compartments. With a defined 215 × 115 mm footprint, designers can plan the supply alongside control boards and terminals. Allow additional space for wiring access and airflow rather than using the body dimensions as the complete installation envelope.

Match the DC bus instead of choosing by wattage alone

Four nominal output versions allow the same product family to address different DC equipment requirements. Choose the required voltage first, then check continuous current and startup demand against that version. This gives engineering and purchasing an exact model suffix to specify and avoids treating every 350W-class supply as electrically interchangeable.

Configure equipment for the intended mains supply

Two manually selected AC ranges support equipment planning for different mains supplies. Include the selector position in assembly and commissioning checks, particularly when the same machine design is delivered to different destinations. The switch must match the actual supply before energizing.

Set the output to the equipment requirement

The ±10% DC adjustment allows final setting within the selected version's limits. Use it to meet the equipment's specified voltage requirement, not to replace choosing the correct model. Verify voltage at the load and retain the applicable current and power limits.

Features, Benefits & Advantages

Χαρακτηριστικό Benefit in equipment design
215 × 115 × 30 mm dimensions Helps preserve installation height in compact equipment while giving designers a defined footprint for mounting and wiring layout.
350W-class, single-output architecture Provides a dedicated DC bus for multiple voltage-compatible loads, making the common supply requirement easier to specify and distribute.
12V, 15V, 24V and 48V versions Matches common equipment voltage requirements without assuming that one output voltage suits every controller, sign or peripheral.
Manually selected AC input, 47-63Hz Accepts 90-132VAC or 180-264VAC when the input-range switch is correctly set for the connected mains. The input specification also lists 240-370VDC; confirm the connections and selector setting for DC use.
Output-dependent efficiency: 85%, 86%, 88% or 89% The listed efficiencies are 85% for LRS-350-12, 86% for LRS-350-15, 88% for LRS-350-24 and 89% for LRS-350-48. Use the selected version's value for conversion-loss and thermal planning; one efficiency value does not apply to every version.
±10% DC output adjustment Allows voltage setting within the selected model's specified limits and the connected equipment's acceptable input range; adjustment does not establish additional current or power capacity.
Fan-equipped construction Moves air through the vented housing to help manage heat in equipment installations. Keep the fan and surrounding airflow path clear.
Προστασία υπερφόρτωσης The overload specification states 110%-150% output cut-off with automatic recovery. Individual branch loads and cables still need suitable system-level protection; the recovery timing and retry interval are not specified.

Typical Service Conditions

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


Select 90–132VAC or 180–264VAC manually before energizing, then verify the chosen DC output and polarity.

Input and load matching for LRS-350

No. Select 90-132VAC or 180-264VAC manually using the input-range switch before applying power. Match the selected DC version to every connected input, then include simultaneous demand and startup transients before energising the equipment. The planning image is a representative LRS-series example, not an exact-model wiring diagram.

LRS-350 manual-selector planning example; use LRS-350 input bands, selection instructions and output options, not the example labels.


Keep fan and ventilation openings unobstructed inside a cabinet selected for the actual environment. Arrows show conceptual airspace, not a measured airflow path.

LRS-350 enclosure and service-space planning

The 30mm body height helps keep the power section compact in shallow equipment compartments. With a defined 215 × 115 mm footprint, designers can plan the supply alongside control boards and terminals. Reserve additional space for terminal access, conductor routing and the host equipment's airflow; the case outline is not a clearance allowance.

LRS-series cabinet-space concept; the exact case, cooling method and mounting are defined by this model's own technical data.


The −20°C to +70°C working range does not establish full output at every temperature. Use the selected version’s load and thermal limits.

Temperature and duty-cycle assessment for LRS-350

The stated working range is -20°C to +70°C, but it does not establish full rated output at +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. Measure the temperature at the installed supply and review the longest expected duty cycle. Keep vents unobstructed; do not substitute room temperature for the operating temperature inside the equipment.

LRS-350 temperature-planning example, not a measured derating curve or a replacement for LRS-350 operating limits.


Functional power-planning illustration only. Have qualified personnel select protection, follow terminal markings and verify safe isolation before work.

LRS-350 fault recovery and protected installation

No. The overload specification states 110%-150% output cut-off with automatic recovery, but does not specify recovery timing or a retry interval. Have a qualified installer check terminal identification, protective earthing and branch protection for the actual assembly. Coordinate restart behaviour with the equipment controls rather than treating supply recovery as a safety function.

Functional power-planning illustration only; follow the exact model's terminal identification and qualified installation instructions.



Application Industries

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


AI illustration of an illuminated retail lightbox and storefront at blue hour.

Commercial signage and backlit displays

Support compatible constant-voltage LED modules in backlit signs, retail lightboxes and exhibition displays. The LRS-350 offers an enclosed supply format for a ventilated equipment compartment. Match the output version, total LED load and installation conditions; the supply is not a substitute for a constant-current LED driver.

AI application illustration — commercial backlit signage, not a photographed LRS-350 installation.


AI illustration of complete self-service parcel lockers and a central pickup screen in a bright indoor lobby.

Self-service parcel and pickup terminals

Supply matched DC control electronics, electronic locks and internal lighting in self-service pickup terminals. The low-profile enclosed format can help integration in a ventilated internal compartment. Budget the combined load and switching demand, and verify each peripheral's voltage; this does not imply UPS operation or direct compatibility with every terminal device.

AI application illustration — parcel pickup terminals, not a photographed LRS-350 installation.


AI illustration of a complete guarded automatic carton-packing machine on a production floor.

Automatic packaging machinery

Provide auxiliary DC power for compatible packaging-machine controllers, sensors, relays and indicators. Separate the control-power budget from the machine's main drives, heaters and other high-demand loads. Select the correct output and AC input setting, and provide ventilation and appropriate upstream protection inside the machine.

AI application illustration — packaging machinery with a separate auxiliary control-power role.


AI illustration of an electronics inspection workbench with a supported PCB fixture and optical inspection equipment.

Electronics assembly and inspection fixtures

Power voltage-compatible fixture controllers, relays, indicators and other auxiliary electronics at an assembly or inspection station. A fixed-output supply can serve this support role without being the measurement instrument. Use a dedicated regulated test source where the DUT, excitation or accuracy requirements demand it; do not present LRS-350 as a programmable laboratory supply.

AI application illustration — electronics inspection fixtures; no measurement or test-performance claim.



Συχνές Ερωτήσεις

Which output versions and current ratings are available?

The listed versions are LRS-350-12: 12V, 0–29A; LRS-350-15: 15V, 0–23.2A; LRS-350-24: 24V, 0–14.6A; and LRS-350-48: 48V, 0–7.3A. Use the exact version's voltage and current range; 350W-class does not establish that every version delivers exactly 350W or that full current is available at every temperature.

Does the input automatically accept different mains voltages?

No. Select 90-132VAC or 180-264VAC manually using the input-range switch before applying power. The AC frequency range is 47-63Hz. The input specification also lists 240-370VDC; confirm the DC input connections and selector setting for the installation. Do not treat the two AC ranges as automatic switching or as one uninterrupted AC range.

How much load margin is required?

Base margin on simultaneous current, startup peaks, duty cycle and cabinet temperature. Do not select solely from average consumption. The listed cold-start input current is 60A at 230VAC; this is not an available DC output current. Measure or obtain the load profile and confirm suitability; there is no universal margin percentage for every installation.

Can the output voltage be adjusted to obtain more power?

No additional output power should be assumed. The adjustment range is ±10%; remain within the selected model's specified current limits and the load's voltage tolerance. Adjustment is not a substitute for another nominal-voltage version or confirmation of the permissible operating power.

Can it run at full rated output at +70°C?

The stated working range is -20°C to +70°C, but it does not establish full rated output at +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. The operating interval alone is not a promise of full output at every temperature. Assess mounting, airflow, actual load and temperature in the finished equipment; the reference curve does not expand the WEHO model's stated operating or output ratings.

Can the LRS-350 be installed outdoors or in a damp location?

Use a suitable protective equipment enclosure and assess moisture, condensation, contamination and heat removal. The enclosed construction alone is not evidence of weather protection or approval for direct outdoor exposure.

Does the LRS-350 include a fan?

Yes. The construction includes a fan to move air through the housing. Preserve airflow through the supply and surrounding cabinet, and include access for inspection in the equipment layout.

Does overload protection replace external circuit protection?

No. The overload specification states 110%-150% output cut-off with automatic recovery, but does not specify recovery timing or a retry interval. Wiring and individual loads still need protection appropriate to their ratings and installation requirements. Select external protective devices as part of the equipment design, not from the supply's power label alone.

Can two LRS-350 units be connected in parallel for higher current or redundancy?

Do not connect outputs together on that assumption. Parallel operation, current sharing and redundancy require explicit confirmation for the exact arrangement. Select a supply or engineered power system intended for that requirement instead.

Can the LRS-350 be used directly as a battery charger?

Do not assume battery-charging capability from the adjustable output. Charging requires compatibility with the battery chemistry, charging profile and protection requirements. Specify a suitable charger or separately engineered charging system.

Can one unit provide several different DC voltages?

No. Each version provides one nominal output voltage. If the equipment requires several voltage rails, specify separate supplies or appropriately rated conversion stages and include their input demand in the main supply budget.

Which technical requirements define an LRS-350 selection?

Specify the exact model suffix, AC or DC input arrangement, required DC voltage, continuous and startup currents, cabinet temperature and installation environment. Check output ripple, voltage tolerance, protection requirements and any required compliance documents for that version. The single-output rating and enclosure dimensions alone do not establish system compatibility, certification coverage or permissible wiring.

Ποια είναι τα καλύτερα προϊόντα Power Supply για την επιχείρησή σας;

Ενισχύστε την επιχείρησή σας με ποιοτικά προϊόντα τροφοδοσίας WEHO.

Ρωτήστε έναν ειδικό
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.