WEHO S-1000 is a single-output switching power supply with separate 12V, 24V, 36V, 48V and 110V variants. The output selection includes a separately printed higher-voltage column as well as the lower-voltage options, helping machine builders distinguish electronic-bay requirements before selecting a suffix. Ask WEHO to review the exact voltage, startup demand and cabinet conditions for the intended equipment.

Εάν έχετε οποιεσδήποτε ερωτήσεις, μη διστάσετε να επικοινωνήσετε μαζί μας στο E-mail: [email protected]

Προσδιορισμός S-1000-12 S-1000-24 S-1000-36 S-1000-48 S-1000-110
DC τάση εξόδου, ρεύμα 12V 0 ~ 80A 24V 0 ~ 42A 36V 0 ~ 28A 48V 0 ~ 21A 110V~9.1A
Κύμα και θόρυβος 150mVp-p 180mVp-p 180mVp-p 240mVp-p 240mVp-p
Σταθερότητα καλωδίου εισόδου ±0,5% ±0,5% ±0,5% ±0,5% ±0,5%
Σταθερότητα φορτίου ±0,5% ±0,5% ±0,5% ±0,5% ±0,5%
Αποδοτικότητα 80% 85% 85% 87% 87%
Ρυθμιζόμενο εύρος για τάση DC ±10% ±10% ±10% ±10% ±10%
Εύρος τάσης εισόδου 100 ~ 132VAC/200 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz
Ρεύμα κρούσης Ρεύμα ψυχρής εκκίνησης 45A/230VAC
Προστασία υπερφόρτωσης 105% ~ 135% cut off the output, automatic recovery
Άλλη προστασία Not specified in this datasheet (overvoltage threshold and short-circuit recovery mode are not stated).
Ρύθμιση, άνοδος, χρόνος αναμονής 2000ms, 50ms, 20ms/230VAC at full load
Αντοχή στην τάση I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute
Αντοχή στην απομόνωση I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ
Θερμοκρασία εργασίας -10°C ~ +50°C
Διάσταση 291 × 132 × 68mm
Βάρος 2,65 κιλά
Συσκευασία 37.5 × 31 × 25.5CM/6PCS/16kg

Why Choose S-1000

Select the required output, not just the family label

The S-1000-12 column lists 12V with a 0 ~ 80A current range. The additional S-1000-110 column is printed as 110V~9.1A, without an explicit lower current bound. This entry does not state a lower current bound or establish touch-safe auxiliary-rail suitability.

Plan selectable input at the equipment site

AC input is 100 ~ 132VAC or 200 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. The explicit input bands help procurement distinguish a switch-selected unit from an automatically ranging supply. Confirm the delivered selector instructions and site supply before energizing; the printed DC range is not a DC wiring procedure.

Reserve an identifiable equipment envelope

The listed body dimensions are 291 × 132 × 68mm and the listed weight is 2.65kg. These entries support an initial cabinet-envelope and handling review. Allow separate room for studs, cable bends, ventilation and servicing; the body size alone does not establish mounting fit or terminal clearance.

Evaluate adjustment against the real electronics tolerance

The DC-voltage adjustment entry is ±10% for every listed output. This provides a defined adjustment entry for a matched rail, but the connected boards must tolerate the final setting and transients. Adjustment is not an additional current rating or a substitute for load qualification.

S-1000 Features and Selection Benefits

Separate line and load stability entries

Inlet-wire stability and load stability are each ±0.5% for every listed output. These figures help compare steady-state regulation requirements. They do not describe output accuracy over every temperature or dynamic step-load performance.

Output-specific wave-and-noise figures

The wave-and-noise entries are S-1000-12: 150mVp-p; S-1000-24: 180mVp-p; S-1000-36: 180mVp-p; S-1000-48: 240mVp-p; S-1000-110: 240mVp-p. Compare the selected column with the electronics noise allowance. Sensitive measurement or communication circuits still need application-level evaluation; no unprinted bandwidth or test fixture is assumed.

Efficiency values tied to each suffix

The efficiency entries are S-1000-12: 80%; S-1000-24: 85%; S-1000-36: 85%; S-1000-48: 87%; S-1000-110: 87%. Use the relevant entry for a preliminary power-loss discussion, not as a measured result for the finished cabinet. The actual input, load, duty cycle and internal temperature govern the thermal review.

A stated overload response, without extra protection promises

Overload protection is listed at 105% ~ 135% with output cutoff and automatic recovery. No separate overvoltage threshold or short-circuit recovery mode is specified on this sheet. Automatic recovery must be considered in the machine restart strategy; it does not qualify the supply as a protective control or eliminate independent branch protection.

Typical S-1000 Service Conditions

Control trimming debris and cabinet hot spots

The printed working-temperature range is -10°C ~ +50°C. For an insulated-panel trimming line, assess compatible job-list and trim-status electronics in a protected electrical bay. Confirm the actual temperature during repeated panel cycles, remove accumulated debris and preserve service access. Cutter, feed and extraction power are independently sized; the temperature entry is not a full-load derating curve.

Separate the electrical bay from centrifuge vibration

AC input is 100 ~ 132VAC or 200 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. At an industrial basket centrifuge, verify the site input and delivered selector instructions before connecting compatible recipe-entry and maintenance-display modules. Use mechanically supported wiring and a dry electrical location away from the drum. Rotor drive, braking and lid protection remain independently engineered.

Review common switch-on demand at a printing press

The only printed cold-start entry is 45A at 230VAC; no 115VAC cold-start value is given. For a large-format screen-printing press, assess artwork-transfer and display electronics against the actual upstream branch and the other equipment energized with them. The printed cold-start figure is not a value for every input band. Keep ink, cleaning liquid, squeegee drives and drying equipment outside the proposed supply duty.

Keep stone-processing moisture away from electronics

Setup, rise and hold-up times are 2000ms, 50ms and 20ms, respectively, at 230VAC at full load. At a stone bridge-saw cell, place compatible cut-list and machine-status electronics in a dry protected bay and validate their response to lost input. Coolant mist and abrasive slurry must not reach the supply. The timing row does not establish process continuity, saw power, pump power or protective-function suitability.

Potential S-1000 Equipment Applications

Rotary indexing assembly dial

A rotary indexing assembly dial may evaluate a qualified S-1000 variant for compatible 24V-input station-status and product-record boards, not indexing drives or tooling actuators. Qualify voltage, communication noise tolerance and the electronic branch through indexing cycles. Do not allocate tooling or indexer power from the family label. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.

Wire-mesh welding line

A wire-mesh welding line may evaluate a qualified S-1000 variant for compatible 24V-input schedule-entry and traceability electronics, not welding-current circuits, feed drives or guards. Check the electronics against the electrical noise and enclosure conditions of the welding line. Welding output, wire-feed drives and protective controls remain separate; no weld-performance claim is made. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.

Industrial roll laminator

An industrial roll laminator may evaluate a qualified S-1000 variant for compatible 12V-input recipe-transfer and operator-display electronics, not roll drives, nip actuators or heaters. Verify display input, cable routing and permitted supply noise before selecting a variant. Nip force, roll motion and heating are outside this proposed role. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.

Vacuum-forming machine

A vacuum-forming machine may evaluate a qualified S-1000 variant for compatible 24V-input job-interface and cycle-record modules, not vacuum pumps, sheet heaters or lift actuators. Assess electronic load, supply interruption and enclosure temperature over a forming cycle. Vacuum generation, sheet heating and lift motion remain independently powered and controlled. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.

S-1000 Technical FAQs

Which S-1000 variants are printed, and what does its power-class label mean?

S-1000-12: 12V, 0 ~ 80A; S-1000-24: 24V, 0 ~ 42A; S-1000-36: 36V, 0 ~ 28A; S-1000-48: 48V, 0 ~ 21A; S-1000-110: printed as 110V~9.1A (no explicit lower current bound). The summary uses the 1000W single-output power-class label. A printed current range is not independently approved rated continuous current. Do not infer a minimum-load rule, a full-temperature continuous power rating or parallel capability from the range or from voltage multiplied by its upper bound.

How is the S-1000 input selected?

AC input is 100 ~ 132VAC or 200 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. The AC bands are not one uninterrupted automatic-ranging input. Verify selector position with power isolated using the delivered instructions. Confirm any intended DC-input connection and polarity separately; the listed DC range does not establish those instructions.

What cold-start input condition is stated for S-1000?

The only printed cold-start entry is 45A at 230VAC; no 115VAC cold-start value is given. Use that input association for upstream switch-on assessment and check aggregate inrush with other cabinet loads. It is not the normal input current, a fuse recommendation or proof of behavior on the other AC band.

What setup, rise and hold-up conditions are stated for S-1000?

Setup, rise and hold-up times are 2000ms, 50ms and 20ms, respectively, at 230VAC at full load. The three values have distinct functions and belong to that printed input/full-load condition. They do not establish stored-data retention, uninterrupted process operation or full-temperature full-load duty; verify the equipment response to loss and return of input.

How do S-1000 wave-and-noise entries vary by output?

S-1000-12: 150mVp-p; S-1000-24: 180mVp-p; S-1000-36: 180mVp-p; S-1000-48: 240mVp-p; S-1000-110: 240mVp-p. Assess sensitive electronic loads against the figures for the selected model. The page does not give a bandwidth, probe arrangement or separate dynamic-noise test condition; qualify the actual electronics and routing rather than inventing those conditions.

How should S-1000 stability and adjustment figures be used?

Inlet-wire stability and load stability are each ±0.5% for every listed output. The DC-voltage adjustment entry is ±10% for every listed output. Line stability, load stability and adjustment describe different attributes. Neither the stability values nor the available adjustment proves an arbitrary electronics tolerance, output accuracy over temperature or permissible extra current after voltage adjustment.

Which efficiency figures belong to the S-1000 suffixes?

S-1000-12: 80%; S-1000-24: 85%; S-1000-36: 85%; S-1000-48: 87%; S-1000-110: 87%. These are output-column entries, not measured cabinet efficiency under the proposed load. Confirm the operating input, output, loading and thermal arrangement before using the figure in a final thermal or energy calculation.

What protection response is specified for S-1000?

Overload protection is listed at 105% ~ 135% with output cutoff and automatic recovery. No separate overvoltage threshold or short-circuit recovery mode is specified on this sheet. The sheet does not explicitly define the percentage reference or a separate fault-current duty. Do not treat automatic recovery as a safety function, permission for unattended restart or a replacement for correctly engineered branch protection.

What environment does the S-1000 sheet describe?

The printed working-temperature range is -10°C ~ +50°C. Storage temperature, working humidity and storage humidity are not specified on this sheet. Confirm the enclosure hot spot, ventilation, contamination and actual electronic load. The working-temperature entry is not a derating curve or approval for full load across that range, and it supplies no ingress rating or process-area approval.

What mechanical and shipping entries are listed for S-1000?

The listed body dimensions are 291 × 132 × 68mm and the listed weight is 2.65kg. Packing is listed as 37.5 × 31 × 25.5CM/6PCS/16kg. The drawing separately marks body and hole references; do not combine them into an unprinted overall cable or stud clearance. Confirm the delivered unit, mounting details and current shipping configuration before final enclosure or logistics design.

What can be taken from the S-1000 terminal drawing?

The front drawing labels the two output studs POS(+) and NEG(-), with a 2-M6 callout; the input view labels FG, N and L beside AC INPUT. No numbered pin legend is printed. The drawing also marks the LED and voltage-adjustment point. The input-strip view shows five screw-like circular positions, but only the inner FG, N and L positions are labelled; the two unlabelled end positions are not assigned an electrical function here. Confirm the delivered variant and terminal arrangement before wiring. FG and output signs alone do not establish the system bonding scheme, output-isolation approval or permitted interconnection.

What withstand and isolation entries are printed for S-1000?

Withstand entries are I/P-O/P: 1.5kV, I/P-FG: 1.5kV and O/P-FG: 0.5kV for 1minute, without a printed AC/DC test qualifier. Isolation resistance is listed as 500VDC/100MΩ for I/P-O/P, I/P-FG and O/P-FG. No AC/DC test-voltage qualifier is stated for these kV entries. These entries are not a certificate, an instruction to perform a field high-voltage test, a touch-safety classification or approval of an equipment grounding arrangement.