S-25W series normal single switching power supply

WEHO S-25 is a 25W-designated single-output power-supply family for compatible local instrument and interface electronics. Separate 5V, 12V, 15V and 24V versions use a 98×97×35mm enclosure. AC input is 90~132VAC/180~264VAC by switch; 254~370VDC is also listed. The S-25-15 column specifies 15V 0~1.67A. Match the exact suffix to the load and confirm startup, continuous duty, thermal conditions and delivered-unit connections.

Εάν έχετε οποιεσδήποτε ερωτήσεις, μη διστάσετε να επικοινωνήσετε μαζί μας στο E-mail: [email protected]

Προσδιορισμός S-25-5 S-25-12 S-25-15 S-25-24
DC τάση εξόδου, ρεύμα 5V   0~5A 12V 0~2.1A 15V0~1.67A 24V0~1.1A
Κύμα και θόρυβος 50mVp-p 50mVp-p 75mVp-p 100mVp-p
Σταθερότητα καλωδίου εισόδου ±0,5% ±0,5% ±0,5% ±0,5%
Σταθερότητα φορτίου ±1% ±0,5% ±0,5% ±0,5%
Αποδοτικότητα 65% 68% 70% 72%
Ρυθμιζόμενο εύρος για τάση DC ±10% ±10% ±10% ±10%
Εύρος τάσης εισόδου 90~132VAC/180~264VAC by switch 254~370VDC 47~63Hz
Ρεύμα κρούσης Cold start current 15A/115VAC 30A/230VAC
Προστασία υπερφόρτωσης 105%~150% διακόπτει την έξοδο, αυτόματη ανάκτηση
Προστασία από υπέρταση 115% ~ 135% shut down O/P voltage, re-power on to recover
Ρύθμιση, άνοδος, χρόνος αναμονής 200ms,100ms,30ms/230VAC at full load
Αντοχή στην τάση I/P-O/P:1,5kV I/P-FG:1,5kV O/P-FG:0,5kV 1 λεπτό
Αντοχή στην απομόνωση I/P-O/P I/P-FG O/P-FG:500VDC/100MΩ
Θερμοκρασία εργασίας -10℃~+50℃
Διάσταση 98×97×35mm
Βάρος 0,3 κιλά
Συσκευασία 43×32.5×24CM/60PCS/18kg

Why Choose the S-25?

Match the 15V option to the electronic load

S-25-15 lists 15V 0~1.67A, giving a specific output option to assess for a compatible interface or display board. Match the board voltage, continuous demand and startup profile to the ordered suffix. The 25W designation and printed range endpoint do not define the complete operating envelope.

Plan the AC selector into the equipment build

The input entry explicitly requires switching between 90~132VAC and 180~264VAC. Equipment built for more than one line-voltage system needs a verified setting and clear assembly instructions. The stated ranges do not describe automatic universal-input selection.

Compare noise and regulation at the intended board

The 5V and 12V versions list 50mVp-p ripple, while 15V and 24V list 75mVp-p and 100mVp-p. The 5V load-stability entry is ±1%, not the ±0.5% of the other outputs. Evaluate the actual board tolerance and wiring rather than applying the best family figure to every option.

Keep terminal orientation in the replacement assessment

The S-25 legend starts with positive and negative DC output at pins 1 and 2, followed by GND and AC input. This arrangement is not interchangeable with every five-terminal S supply. Check the exact unit markings, mounting drawing and service access before selecting a replacement.

S-25 Features

Four separate single-output alternatives

The printed columns are S-25-5, S-25-12, S-25-15 and S-25-24. They list 5V 0~5A, 12V 0~2.1A, 15V 0~1.67A and 24V 0~1.1A respectively. These are alternative ordered variants, not four rails delivered simultaneously by one unit.

Adjustment with output-dependent stability

Each model lists ±10% DC-voltage adjustment and ±0.5% line stability. Load stability is ±1% for S-25-5 and ±0.5% for the other models. Adjustment does not establish regulated-current output, programmable operation or a charging function.

Two specified cold-start input conditions

Cold-start current is 15A/115VAC and 30A/230VAC. Assess upstream switching at the intended line-voltage condition. These are transient entries, not continuous input-current ratings or approval for arbitrary rapid power cycling.

Conditioned startup and fault recovery

Setup, rise and hold-up are 200ms, 100ms and 30ms at 230VAC and full load. Overload cutoff has automatic recovery; overvoltage shutdown requires re-powering. The connected equipment needs its own reset and safe-restart assessment.

Typical Service Conditions

Protect a roll-diameter display enclosure

A roll-diameter display enclosure may evaluate an exact S-25 output for compatible readout and interface electronics. Keep the supply separated from web dust and moving material, with controlled mains routing. Roll drives, tension actuators and the measurement result require independent qualification.

Check moisture around an ultrasonic-cleaner control fascia

An ultrasonic-cleaner control fascia needs a dry electrical compartment protected from vapour and cleaning fluid. Consider S-25 only for a compatible user-interface board after load and thermal checks. The ultrasonic generator, tank heaters and liquid-area safety are separate functions.

Segregate signals in a pressure-decay tester console

A pressure-decay tester should separate mains routing from pressure-sensor and communication wiring. An accepted S-25 suffix could supply only compatible local electronics. Valve actuation, sensor excitation, pressure generation and leak-measurement accuracy need their own engineering evidence.

Assess heat in a compact pallet-ID reader station

A pallet-ID reader station must evaluate compartment temperature, board startup and output noise in the actual enclosure. The -10°C~+50°C entry is not a full-load derating curve. Reader compatibility, network isolation and conveyor drive power are not established by the supply choice.

Potential S-25 Applications

Bench torque-display unit

Evaluate a selected S-25 voltage for compatible torque-display and communication electronics. Confirm load tolerance, interruption behavior and installation conditions. Transducer excitation, calibrated torque accuracy and any motorized loading mechanism remain separately qualified functions.

Industrial oven status repeater

A protected oven-status repeater may assess an exact output for compatible indication and interface boards outside the hot process zone. Verify local ambient conditions and AC selection. Heaters, blowers, overtemperature trips and the oven control system require their own supplies and safety design.

Cable continuity test console

Consider an accepted S-25 variant for compatible local logic and display electronics in a continuity-test console. The test excitation, measurement reference, channel isolation and protective circuits must be separately designed. A DC supply selection does not establish tester accuracy or test-voltage capability.

Spool-end detection interface

A spool-end detection interface may evaluate a qualified S-25 output for compatible status electronics. Check each detector’s voltage and switching demand, and protect the electrical compartment from fibre accumulation. Winding drives, machine-stop actuation and functional safety are outside this proposed electronic role.

S-25 Technical FAQs

Which exact output models and current ranges are listed?

S-25-5 lists 5V 0~5A; S-25-12 lists 12V 0~2.1A; S-25-15 lists 15V 0~1.67A; S-25-24 lists 24V 0~1.1A. They are alternative single-output models, not four simultaneous rails.

Does the 25W designation approve every continuous operating point?

The 25W family designation and the printed current ranges are separate entries, not a complete continuous operating envelope. Confirm the ordered suffix’s continuous and startup duty at the intended input and local temperature. The printed zero lower bounds do not independently establish minimum-load requirements or no-load regulation.

Is the AC input automatically selected?

AC input is 90~132VAC/180~264VAC by switch. The input row also lists 254~370VDC and 47~63Hz. Select the correct AC band before energizing; this is not automatic range selection. Confirm the delivered unit’s separate DC-input connection requirements before DC use.

What does the voltage-adjustment entry establish?

Each model lists ±10% DC-voltage adjustment. It does not establish regulated-current output, dimming, arbitrary programmable operation or battery charging. Confirm the adjustment procedure, connected load voltage limits and accepted operating envelope before using a changed setting.

What ripple and line/load stability apply to each output?

S-25-5: 50mVp-p; S-25-12: 50mVp-p; S-25-15: 75mVp-p; S-25-24: 100mVp-p. All four list ±0.5% line stability; the 5V version lists ±1% load stability and the other outputs ±0.5%. No ripple measurement bandwidth or wiring method is specified by these entries.

Which efficiencies and cold-start values belong to this model?

Efficiencies in S-25-5, S-25-12, S-25-15, S-25-24 order are 65%, 68%, 70%, 72%. Cold-start current is 15A/115VAC and 30A/230VAC. Keep each efficiency with its output and each inrush value with its input; the inrush figures are not continuous input-current ratings.

How does overload protection recover?

The overload entry is 105%~150%, cutting off the output with automatic recovery. This is not a continuous overload allowance or a replacement for cable and branch protection. Evaluate the connected electronics’ behavior during repeated power loss and recovery as part of the equipment design.

Does overvoltage shutdown recover automatically?

The overvoltage entry is 115%~135%, shutting down the output voltage and requiring re-powering to recover. Keep this separate from automatic overload recovery. Safe restart and downstream protection need their own equipment-level verification.

Which setup, rise and hold-up values and conditions are specified?

Setup, rise and hold-up are 200ms, 100ms and 30ms at 230VAC and full load. The stated conditions apply to this timing entry; full-load timing does not establish full load throughout the temperature range or identical response at every input and load.

What working temperature, dimensions and mass are listed?

The values are -10°C~+50°C, 98×97×35mm and 0.3kg. Check actual mounting, terminal access, service clearance and local thermal conditions. These entries do not provide an ingress rating, humidity specification or complete full-load derating curve.

What withstand and isolation-resistance entries are printed?

The withstand row lists I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute, without an AC/DC qualifier. Isolation resistance is listed as 500VDC/100MΩ for the named input/output/frame-ground pairs. These component test entries do not establish certification scope or finished-equipment approval.

What terminal order is shown, and can it be transferred between models?

The S-25 legend labels pin 1 as DC output+V, pin 2 as DC output-V, pin 3 as GND and pins 4 and 5 as AC input. Confirm the exact delivered markings and connection instructions before wiring, including any separate DC-input application. The legend does not establish interchangeable wiring with another model.