Product Categories

LRS-150 Series 150W Single Output Enclosed Switching Power Supply (LRS-150-12 / LRS-150-24 / LRS-150-48)

Input Range: LRS-150 lists 85~264VAC or 120~373VDC, 47~63Hz.
Single-Output Versions: 12V, 15V, 24V and 48V, with listed current ranges of 0~12.5A, 0~10A, 0~6.5A and 0~3.3A respectively.
Efficiency by Version: 87.5%, 89%, 89% and 90% in the same voltage order.
Compact Dimensions: 159×97×30mm, with a 30mm profile.
Adjustment and Protection: DC output-voltage adjustment is ±10%. Overload protection is 110%~150%, cutting off the output with automatic recovery; overcurrent and short-circuit protection are also listed.
Working Temperature: -20℃ to +70℃.

Overview

The LRS-150 is a single-output AC/DC power supply. It is a candidate for auxiliary electronics in packaging lines, process equipment and interactive installations. The specified overall dimensions are 159 × 97 × 30 mm. Separate voltage models let the equipment designer select a matched electronics rail without using a larger machine-drive supply for that task. Share the required output and load profile with the project team when selecting the variant.

Why Choose LRS-150?

Match the accessory rail

The LRS-150 offers separate 12 V, 15 V, 24 V and 48 V models: LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. Choose the voltage accepted by the complete accessory group instead of assuming every sensor and interface shares an input.

Plan a shallow equipment base

The specified overall dimensions are 159 × 97 × 30 mm. A defined body envelope helps reserve space for a guarded electronics compartment while leaving wiring and service access outside that outline.

Evaluate AC or DC input architecture

The input specification lists 85–264 VAC / 120–373 VDC and 47–63 Hz. The documented input alternatives help screen the intended upstream source before protection and distribution are designed.

Compare the selected voltage model

The listed efficiencies are 87.5%, 89%, 89% and 90% for LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. Model-specific figures are more useful for preliminary loss budgeting than a single best-case family headline.

Features, Benefits & Advantages

Característica Benefit in equipment design
Defined current-range choices The printed output-current ranges are 0–12.5 A, 0–10 A, 0–6.5 A and 0–3.3 A for LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. Use the printed ranges as selection inputs alongside the series-power boundary, not as permission for untested overload or motor starting.
Separate line and load regulation Line regulation and load regulation are each listed as ±0.5%. Include cable drop and dynamic behavior separately in the equipment voltage budget.
DC voltage adjustment The DC-voltage adjustment range is listed as ±10%. Set the rail within the connected electronics input limits and verify the voltage at the load.
Documented overload response Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. Coordinate branch protection and machine restart behavior instead of relying on supply recovery as a safety function.
Especificación LRS-150-12 LRS-150-15 LRS-150-24 LRS-150-48
Tensión de salida CC, corriente 12V 0~12.5A 15V 0~10A 24V 0~6.5A 48V 0~3.3A
Ola y ruido 150mVp-p 150mVp-p 150mVp-p 200mVp-p
Estabilidad del cable de entrada ±0,5% ±0,5% ±0,5% ±0,5%
Estabilidad de carga ±0,5% ±0,5% ±0,5% ±0,5%
Eficiencia 87.5% 89% 89% 90%
Rango ajustable para voltaje CC ±10% ±10% ±10% ±10%
Rango de voltaje de entrada 85~264VAC / 120~373VDC, 47~63Hz
Corriente de impacto Corriente de arranque en frío 60A/230VAC
Protección contra sobrecarga 110%~150%corta la salida, recuperación automática
Otra protección Protección contra sobrecorriente/protección contra cortocircuitos
Timing (setup / rise / hold-up) 230VAC: 500ms, 30ms; 115VAC: 500ms, 30ms. No separate hold-up time is specified.
Voltaje de soporte I/P-O/P:1,5 kV I/P-FG:1,5 kV O/P-FG:0,5 kV 1 minuto
Resistencia de aislamiento I/P-O/P I/P-FG O/P-FG: 100 M ohmios/500 VCC/25 ℃/70%RH
Temperatura de trabajo -20℃~+70℃
Dimensión 159×97×30mm
Peso 0,45 kg
Embalaje 42,5 × 34 × 19,5 cm/40 unidades/17 kg.

Mechanical dimensions

LRS-150 — dimensions in millimetres
Body length159 mm
Body width97 mm
Body height30 mm

The body dimensions and mounting-hole dimensions are different references. The vector drawing below retains the dimensions printed in the WEHO original.

On a small screen, swipe the drawing horizontally to inspect every dimension. No separate drawing image or script download is required.

Exact mechanical drawing from the WEHO original. Units: mm. Use the printed body, mounting and hole dimensions separately.

Load derating

Apply these model-specific curves only within the stated WEHO operating range of -20 to +70 °C and the input range in the specification table. A reference axis extending below that range does not extend the product rating. Follow the input-voltage and mounting-orientation labels shown on each curve.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus ambient temperature. Observe the separate input-voltage curves where shown.
Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus AC input voltage at the frequency shown. Use the correct input selector setting where applicable.
View the functional block diagram Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.

Typical Service Conditions

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


Select 90–132VAC or 180–264VAC manually before energizing, then verify the chosen DC output and polarity.

Input matching: LRS-150 versus the selector example

The illustration shows the LRS-350 manual-range example; do not transfer its 90–132/180–264 VAC bands to LRS-150. The input specification lists 85–264 VAC / 120–373 VDC and 47–63 Hz. The input range does not document a selector switch or an automatic range-switching mechanism. Match the selected DC version to every connected input, then include simultaneous demand and startup transients before energising the equipment. The planning image is a representative LRS-series example, not an exact-model wiring diagram.

LRS-350 manual-selector planning example; use LRS-150 input bands, selection instructions and output options, not the example labels.


Keep fan and ventilation openings unobstructed inside a cabinet selected for the actual environment. Arrows show conceptual airspace, not a measured airflow path.

LRS-150 enclosure and service-space planning

The specified overall dimensions are 159 × 97 × 30 mm. The listed product weight is 0.45 kg. Reserve additional space for terminal access, conductor routing and the host equipment's airflow; the case outline is not a clearance allowance.

LRS-series cabinet-space concept; the exact case, cooling method and mounting are defined by this model's own technical data.


The −20°C to +70°C working range does not establish full output at every temperature. Use the selected version’s load and thermal limits.

Temperature and duty-cycle assessment for LRS-150

The specified working-temperature range is -20°C to +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. Measure the temperature at the installed supply and review the longest expected duty cycle. Keep vents unobstructed; do not substitute room temperature for the operating temperature inside the equipment.

LRS-350 temperature-planning example, not a measured derating curve or a replacement for LRS-150 operating limits.


Functional power-planning illustration only. Have qualified personnel select protection, follow terminal markings and verify safe isolation before work.

LRS-150 fault recovery and protected installation

Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. Have a qualified installer check terminal identification, protective earthing and branch protection for the actual assembly. Coordinate restart behaviour with the equipment controls rather than treating supply recovery as a safety function.

Functional power-planning illustration only; follow the exact model's terminal identification and qualified installation instructions.



Application Industries

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


AI illustration of an illuminated retail lightbox and storefront at blue hour.

Retail sign-control and LED-module branches

For the retail lightbox scene, evaluate LRS-150 for a voltage-matched LED-module group and its local controls, with separately assessed current regulation where necessary. Include simultaneous module demand, cable loss and startup. Do not infer a complete building-lighting rating from the supply family name.

The LRS-150-24 column lists 24 V and an output-current range of 0–6.5 A.

AI application concept — retail signage, not an installation record for this product.


AI illustration of complete self-service parcel lockers and a central pickup screen in a bright indoor lobby.

Parcel-terminal interface electronics

A bank of pickup lockers can separate control, detection and door-release circuits into protected groups. Consider an LRS-150 branch only after matching every connected input and checking the maximum release combination. Any display supply and backup arrangement need separate acceptance.

The LRS-150-12 column lists 12 V and an output-current range of 0–12.5 A.

AI application concept — parcel-terminal electronics, not an installation record for this product.


AI illustration of a complete guarded automatic carton-packing machine on a production floor.

Carton-packaging auxiliary electronics

At an automatic carton station, assess LRS-150 for compatible controller interfaces, presence sensors and indication. Include converter startup and switching disturbances from nearby motion equipment. Keep the forming drive, pneumatic actuation and safety system outside the proposed branch.

The LRS-150-15 column lists 15 V and an output-current range of 0–10 A.

AI application concept — carton-packaging auxiliary electronics, not a complete-machine power claim.


AI illustration of an electronics inspection workbench with a supported PCB fixture and optical inspection equipment.

Electronics-fixture auxiliary interfaces

An electronics inspection bench may use LRS-150 for compatible fixture-control and auxiliary interfaces while a dedicated source serves the DUT. If the chosen rail is higher than the electronics input, qualify an appropriate converter. Neither camera compatibility nor measurement performance follows from the scene.

The LRS-150-48 column lists 48 V and an output-current range of 0–3.3 A.

AI application concept — electronics-fixture interfaces; no measurement-performance or installed-model claim.



Preguntas frecuentes

Which output-voltage models does the LRS-150 provide?

The LRS-150 offers separate 12 V, 15 V, 24 V and 48 V models: LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. Each model is a single-output choice; the alternatives are not simultaneous rails on the same unit.

How are the LRS-150 current ranges and series-power statement distinguished?

The printed output-current ranges are 0–12.5 A, 0–10 A, 0–6.5 A and 0–3.3 A for LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. The series summary states "Single output: power 150W". The sheet gives no separate continuous-wattage row for each output variant; the summary power and the printed current endpoints must remain separate selection facts. Continuous-load acceptance must keep both source statements in view, with transient demand and thermal conditions reviewed for the actual design.

Which input range is specified for the LRS-150?

The input specification lists 85–264 VAC / 120–373 VDC and 47–63 Hz. The input range does not document a selector switch or an automatic range-switching mechanism. Confirm source behavior and input wiring from the applicable product documentation before integration.

What body size and weight are listed for the LRS-150?

The specified overall dimensions are 159 × 97 × 30 mm. The listed product weight is 0.45 kg. Overall dimensions support space planning, not mounting-hole, terminal-clearance or enclosure-access dimensions.

How does LRS-150 efficiency vary by output model?

The listed efficiencies are 87.5%, 89%, 89% and 90% for LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. The sheet does not give the efficiency or ripple measurement conditions, so these figures are not a complete equipment-level performance guarantee. Use the figure for the selected output model, then assess losses under the actual equipment load.

Which ripple-and-noise figures are listed for the LRS-150?

The listed ripple-and-noise values are 150 mVp-p, 150 mVp-p, 150 mVp-p and 200 mVp-p for LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. The sheet does not give the efficiency or ripple measurement conditions, so these figures are not a complete equipment-level performance guarantee. A sensitive camera or measurement interface needs a load-side noise check with the actual cabling and other loads operating.

What do the LRS-150 line- and load-regulation figures describe?

Line regulation and load regulation are each listed as ±0.5%. These are separate line- and load-regulation figures, not an additional overall output-voltage tolerance. Cable drop and load-step response remain separate parts of the connected-equipment voltage budget.

What does the LRS-150 DC-voltage adjustment specification establish?

The DC-voltage adjustment range is listed as ±10%. The adjustment specification does not establish dimming, programmability or a constant-current operating mode. The connected equipment input window limits the permissible final setting.

How does LRS-150 overload protection respond?

Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. The overload threshold is not an extra continuous-load allowance, and recovery is not a machine safety or redundant-power function.

Which startup figures are listed for the LRS-150?

The listed cold-start current is 60 A at 230 VAC. The setup/rise row gives 500 ms and 30 ms at 230 VAC, and 500 ms and 30 ms at 115 VAC. The row includes hold-up in its heading but prints no separate hold-up duration or full-load test condition. Upstream protection, simultaneous energization and electronics-ready sequencing require system-level assessment.

What working-temperature boundary is documented for the LRS-150?

The specified working-temperature range is -20°C to +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. The operating interval alone is not a promise of full output at every temperature. Assess mounting, airflow, actual load and temperature in the finished equipment; the reference curve does not expand the WEHO model's stated operating or output ratings.

Which insulation test figures are listed for the LRS-150?

The withstand figures are 1.5 kV from input to output, 1.5 kV from input to FG and 0.5 kV from output to FG, each for 1 minute. Isolation resistance is listed as 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. These test figures do not establish an ingress rating or product certification. Assembly earthing, protective barriers and end-equipment conformity need their own verification.