Overview
The LRS-150 is a single-output AC/DC power supply. It is a candidate for auxiliary electronics in packaging lines, process equipment and interactive installations. The specified overall dimensions are 159 × 97 × 30 mm. Separate voltage models let the equipment designer select a matched electronics rail without using a larger machine-drive supply for that task. Share the required output and load profile with the project team when selecting the variant.
Why Choose LRS-150?
Match the accessory rail
The LRS-150 offers separate 12 V, 15 V, 24 V and 48 V models: LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. Choose the voltage accepted by the complete accessory group instead of assuming every sensor and interface shares an input.
Plan a shallow equipment base
The specified overall dimensions are 159 × 97 × 30 mm. A defined body envelope helps reserve space for a guarded electronics compartment while leaving wiring and service access outside that outline.
Evaluate AC or DC input architecture
The input specification lists 85–264 VAC / 120–373 VDC and 47–63 Hz. The documented input alternatives help screen the intended upstream source before protection and distribution are designed.
Compare the selected voltage model
The listed efficiencies are 87.5%, 89%, 89% and 90% for LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. Model-specific figures are more useful for preliminary loss budgeting than a single best-case family headline.
Features, Benefits & Advantages
| Característica | Benefit in equipment design |
|---|---|
| Defined current-range choices | The printed output-current ranges are 0–12.5 A, 0–10 A, 0–6.5 A and 0–3.3 A for LRS-150-12, LRS-150-15, LRS-150-24 and LRS-150-48, respectively. Use the printed ranges as selection inputs alongside the series-power boundary, not as permission for untested overload or motor starting. |
| Separate line and load regulation | Line regulation and load regulation are each listed as ±0.5%. Include cable drop and dynamic behavior separately in the equipment voltage budget. |
| DC voltage adjustment | The DC-voltage adjustment range is listed as ±10%. Set the rail within the connected electronics input limits and verify the voltage at the load. |
| Documented overload response | Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. Coordinate branch protection and machine restart behavior instead of relying on supply recovery as a safety function. |