| Modelo | XLG-400-24 | XLG-400-36 | XLG-400-48 |
| voltaje de salida CC | 24V | 36V | 48V |
| Corriente de salida nominal | 16.5A | 11A | 8.3A |
| Rango actual | 0~16.5A | 0~11A | 0~8.3A |
| Output power | 396W | 396W | 398.4W |
| Ola y ruido | 180mVp-p | 200mVp-p | 220mVp-p |
| Precisión de voltaje | ± 3% | ± 2% | ± 2% |
| Line regulation | ± 0.5% | ± 0.5% | ± 0.5% |
| Load regulation | ± 2% | ± 0.5% | ± 0.5% |
| Start, rise, hold time | 200ms,30ms,20ms/230VAC (at full load) | ||
| Rango de voltaje de entrada | 180 ~264VAC,235 ~373VDC | ||
| Rango de frecuencia | 47 ~ 63Hz | ||
| Corriente de entrada CA | 4.0A/230VAC | ||
| Eficiencia | 92.3% | 93.0% | 94.0% |
| Impulse current | Cold start current 45A/230VAC | ||
| Leakage current | <2mA/240VAC | ||
| Overcurrent protection | 95%~108% of the rated output current starts overcurrent limit, recover automatically after abnormal conditions are removed |
||
| Protección contra cortocircuitos | Protection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed | ||
| Protección contra sobretensión | 115%~ 135% of rated output voltage startup overvoltage protection | ||
| Protection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed | |||
| Protección contra sobrecalentamiento | 95℃ ±10℃ (JK1 is next to the transformer/MOS tube surface detection) | ||
| Protection mode: Turn Off the output voltage, and the normal output can be automatically restored after the temperature drops |
|||
| Temperatura de trabajo | -20℃~ +60℃ | ||
| Working humidity | 20% ~90% RH, non condensing | ||
| Storage temperature and humidity | -40℃~ +85℃;10% ~95% RH,non condensing | ||
| Seismic resistance | 10~500Hz,,3G 12min/ 1 cycle,X, Y, Z axes,duration 60 minutes | ||
| Resistencia a la presión | I/P~O/P:1.5KVAC I/P~FG:1.5KVAC O/P~FG:0.5KVAC | ||
| Resistencia de aislamiento | I/P~O/P,I/P~FG,O/P~FG: 100M Ohms/500VDC/25℃/70%RH | ||
| Safety standard | Compliance to UL60950-1,TUV EN60950-1 | ||
| Electromagnetic compatibility emission | Compliance to EN55022 Class A | ||
| Electromagnetic compatibility immunity | Compliance to EN55024 | ||
| Dimensión | 240*69*43mm (L*W*H) | ||
| Embalaje | 1.26kg/16pcs/21.5kg/0.026 cubic meters | ||
400W LED Driver AC 110V 220V To DC 24V 36V 48V Constant Voltage Waterproof IP67 Switching Power Supply
XLG-400W series is a waterproof AC DC LED drive power supply. It adopts fanless design and can work in the cabinet temperature range of -20℃ to + 60℃ under natural air cooling and heat dissipation, with 105℃ long-life aluminum electrolytic capacitor built in.
The XLG-400W has complete protection functions (short circuit/overload/overvoltage/overtemperature protection) and anti -5G vibration capabilities. It complies with safety regulations such as UL1012 and EN60950-1, and can meet the energy-saving needs of the new generation of LED lighting. LED lighting provides a cost-effective solution.If you have any questions, please do not hesitate to contact us at Correo electrónico: [email protected]
- Descripción
¿Cuáles son los mejores productos de fuentes de alimentación para su empresa?
Impulsa tu negocio con productos de suministro de energía de calidad WEHO.
Pregúntale a un experto