| Modèle | MDR-100-12 | MDR-100-15 | MDR-100-24 | MDR-100-48 | |
| Sortir | DC Voltage | 12V | 15V | 24V | 48V |
| Rated Current | 7.5A | 6.7A | 4A | 2A | |
| Current Range | 0 ~ 7.5A | 0 ~6.7A | 0 -4A | 0-2A | |
| Puissance nominale | 100W | 100W | 100W | 100W | |
| Ripple & Noise (max.) | 80 mVcrête à crête | 120 mVcrête à crête | 150 mVcrête à crête | 200 mVcrête à crête | |
| Volage ADJ Range | 12 -13.2V | 15-16.5V | 24 – 26.4V | 48 ~ 56V | |
| Voltage Tolerance | ±2.0% | ±1,0% | ±1,0% | ±1,0% | |
| Régulation de ligne | ±1,0% | ±1,0% | ±1,0% | ±1,0% | |
| Régulation de charge | ±1.5% | ±1,0% | ±1,0% | ±1,0% | |
| Setup, Rise Time Note.5 | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load |
||||
| Hold Up Time (Typ.) | 50ms/230VAC 20ms/115VAC at full load |
||||
| Saisir | Voltage Range | 85~264VAC 120~370VDC |
|||
| Frequency Range | 47 ~ 63Hz | ||||
| Efficiency (Typ.) | 78% | 86% | 88% | 87% | |
| AC Current(Typ.) | 1.8A/115VAC 1A/230VAC |
||||
| Inrush Current (Typ.) | Cold start: 30A/115VAC, 60A/230VAC |
||||
| Courant de fuite | <1mA/240VAC | ||||
| Protection | Overload | 105% – 150% rated output power | |||
| Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||||
| Overvoltage | 6.25-7.25V | 15.6 – 18V | 31.2-36V | 57.6 – 64.8V | |
| Protection type: Shut down o/p voltage, re-power on to recover | |||||
| Fonction | DC Signal | Relay contact rating (max.): 30V/1A resistive | |||
| Environnement | Working Humidity | 20% ~ 90%RH non-condensing | |||
| Storage Temp, Humidity | -40°C ~ +85°C, 10% ~ 95%RH | ||||
| Temp Coefficient | ±0.03%/°C (0 – 50°C) | ||||
| Vibration | Component: 10 – 500Hz, 2G 10min./1 cycle, the period for 60min. each along X, Y, and Z axes; Mounting: Compliance to IEC60068-2-6 | ||||
| Safety & EMC | Normes de sécurité | UL508, UL60950-1, TUV EN60950-1 approved | |||
| Withstand Voltage | l/P-0/P: 3KVAC l/P-FG: 2KVAC 0/P-FG: 0.5KVAC |
||||
| Isolation Resistance | l/P-O/P, l/P-FG, 0/P-FG:>100M Ohms/500VDC/25°C/70% RH | ||||
| EMC Emission | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 | ||||
| EMC Immunity | Compliance to EN6100(M-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A | ||||
| Autres | MTBF | 299.2K hrs min. MIL-HDBK-217F (25°C) | |||
| Dimension | 50*90*100mm (W*H*D) | ||||
| Emballage | 0.42Kg; 30pcs/20Kg/0.82CUFT | ||||
| Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25°C of ambient temperature. | ||||
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. | |||||
| 3. Tolerance: includes set up tolerance, line regulation, and load regulation. | |||||
| 4. The power supply is considered a component that will be installed into the final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies. | |||||
| 5. The length of set-up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the set-up time. | |||||
Plastic shell 5V/12V/24V/48V dc dinrail power supply 100w
MDR-100 is a slim line DIN rail Class I switching power supply.
Designed with a fully isolated plastic case to prevent user contact and the risk of shock.Featuring up to 88% efficiency this series can be cooled using only free air convection up to 60°C which significantly increases the reliability and lifetime of the power supply.Other standard features include its low no-load power consumption, to save energy, short circuit, overload, and over voltage protections, and DC OK relay contact with LED indicator for monitoring the PSU status.If you have any questions, please do not hesitate to contact us at E-mail: [email protected]
- Description
Quick Deliver after putting an order, within 3-7 works days for common models
Tous les produits sont soumis à des procédures de tests standardisées pendant la production.
Nous fabriquons nous-mêmes des transformateurs et des inductances de puissance avec du cuivre pur,
Global wide input volatge range 100V to 264V AC
This product is small and easy to install, which is space and cost-efficient.
Fixed switching frequency at 70KHz
The product can be cooled by convection of natural air.
Save space and cost
Quels sont les meilleurs produits d’alimentation électrique pour votre entreprise ?
Boostez votre entreprise avec les produits d'alimentation électrique de qualité WEHO.
Demandez à un expert