Check the rail position
Allow for the 40 × 90 × 100 mm housing on TS35/7.5 or TS35/15 rail. The drawing dimensions exclude the cable bend and working space.
MDR-60 is a slim line DIN rail Class I switching power supply.
Designed with a fully isolated plastic case to prevent user contact and the risk of shock.Efficiency varies by output model. Operating temperature: -10°C to +50°C; apply the specified derating and installation conditions.Other standard features include its low no-load power consumption, to save energy, short circuit, overload, and over voltage protections, and DC OK relay contact with LED indicator for monitoring the PSU status.If you have any questions, please do not hesitate to contact us at E-mail: [email protected]
Size the control branch by its voltage and current: the 5 V version and the 48 V version have different load limits.
| Paramètre | MDR-60-5 | MDR-60-12 | MDR-60-24 | MDR-60-48 |
|---|---|---|---|---|
| DC output voltage and current | 5 V · 0–10 A | 12 V · 0–5 A | 24 V · 0–2.5 A | 48 V · 0–1.25 A |
| Efficacité | 76% | 84% | 86% | 86% |
| Ripple and noise | 80 mV p-p | 120 mV p-p | 150 mV p-p | 200 mV p-p |
| Régulation de ligne | ±1% | ±1% | ±1% | ±1% |
| Régulation de charge | ±1,5% | ±1% | ±1% | ±1% |
| DC voltage adjustment | ±2% | ±1% | ±1% | ±1% |
| AC input | 85–264 VAC | |||
| DC input | 120–370 VDC | |||
| Dimensions (W × H × D) | 40 × 90 × 100 mm | |||
| Input frequency | 47–63 Hz | |||
| Cold-start inrush | 30 A at 115 VAC; 60 A at 230 VAC | |||
| Protection contre les surcharges | 105–150%; output cuts off and recovers automatically. | |||
| Protection contre les surtensions | 120–140%; output shuts down. Cycle input power to recover. | |||
| Setup / rise at full load | 500 / 30 ms at 230 VAC; 500 / 30 ms at 115 VAC. | |||
| Hold-up time | Not specified. | |||
| Withstand voltage (1 min) | Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV. | |||
| Résistance à l'isolation | 100 MΩ at 500 VDC: input/output, input/FG and output/FG. | |||
| Température de travail | −10 °C to +50 °C | |||
| Mounting rail | TS35/7.5 or TS35/15 | |||
| Unit weight | 0.33 kg | |||
| Emballage | 45.5 × 32.5 × 23 cm / 60 pcs / 20 kg | |||
| DC OK relay | Closed: power on / DC normal; open: power off / DC fault. Maximum contact rating: 30 V / 1 A, resistive load. | |||
| Modèle | Sortir | Actuel | Efficacité |
|---|---|---|---|
| MDR-60-5 | 5 V | 0–10 A | 76% |
| MDR-60-12 | 12 V | 0–5 A | 84% |
| MDR-60-24 | 24 V | 0–2.5 A | 86% |
| MDR-60-48 | 48 V | 0–1.25 A | 86% |
| Ripple and noise | 80 mV p-p |
|---|---|
| Régulation de ligne | ±1% |
| Régulation de charge | ±1,5% |
| DC voltage adjustment | ±2% |
| Ripple and noise | 120 mV p-p |
|---|---|
| Régulation de ligne | ±1% |
| Régulation de charge | ±1% |
| DC voltage adjustment | ±1% |
| Ripple and noise | 150 mV p-p |
|---|---|
| Régulation de ligne | ±1% |
| Régulation de charge | ±1% |
| DC voltage adjustment | ±1% |
| Ripple and noise | 200 mV p-p |
|---|---|
| Régulation de ligne | ±1% |
| Régulation de charge | ±1% |
| DC voltage adjustment | ±1% |
| AC input | 85–264 VAC |
|---|---|
| DC input | 120–370 VDC |
| Dimensions (W × H × D) | 40 × 90 × 100 mm |
| Input frequency | 47–63 Hz |
| Cold-start inrush | 30 A at 115 VAC; 60 A at 230 VAC |
| Protection contre les surcharges | 105–150%; output cuts off and recovers automatically. |
| Protection contre les surtensions | 120–140%; output shuts down. Cycle input power to recover. |
| Setup / rise at full load | 500 / 30 ms at 230 VAC; 500 / 30 ms at 115 VAC. |
| Hold-up time | Not specified. |
| Withstand voltage (1 min) | Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV. |
| Résistance à l'isolation | 100 MΩ at 500 VDC: input/output, input/FG and output/FG. |
| Température de travail | −10 °C to +50 °C |
| Mounting rail | TS35/7.5 or TS35/15 |
| Unit weight | 0.33 kg |
| Emballage | 45.5 × 32.5 × 23 cm / 60 pcs / 20 kg |
| DC OK relay | Closed: power on / DC normal; open: power off / DC fault. Maximum contact rating: 30 V / 1 A, resistive load. |
40 × 90 × 100 mm

Width and height are dimensioned on the front view.

Depth is dimensioned on the side view; it does not include field wiring.

Rail profile from the model sheet. Mounting types: TS35/7.5 and TS35/15.
Terminal groups: 1 and 2 — AC input; 3 — ground; 4 — DC positive; 5 — DC negative; 6 — DC OK. Follow the markings on the actual unit. Do not infer DC-input polarity from the AC labels.
The DC OK relay reports output status. Its resistive-contact rating is not the supply output rating.
For the 5 V version, check voltage drop at the load as well as the printed 0–10 A supply range. Its load regulation is ±1.5%.
The MDR-60 brings a regulated DC branch and a status relay to the rail. Choose the output from the load label, then use its own column for current, ripple and efficiency.
| Fonctionnalité | What to check |
|---|---|
| Voltage selection | Choose a fixed output suffix before comparing current ranges. |
| Status monitoring | The DC OK relay reports output status. Its resistive-contact rating is not the supply output rating. |
| Service access | Allow for the 40 × 90 × 100 mm body plus wiring and access to the voltage trim. |
| Power budget | For the 5 V version, check voltage drop at the load as well as the printed 0–10 A supply range. Its load regulation is ±1.5%. |
The photo identifies one specimen; electrical data on this page come from the WEHO model sheet.

Allow for the 40 × 90 × 100 mm housing on TS35/7.5 or TS35/15 rail. The drawing dimensions exclude the cable bend and working space.

The photograph identifies MDR-60-12. With power isolated, check the full suffix and terminal markings on the unit being installed. A different output choice is a different version.

For MDR-60-24, the printed current range is 0–2.5 A. Add the branch loads that can start together; do not substitute input inrush for DC capacity.

The input inrush is 30 A at 115 VAC; 60 A at 230 VAC. Check the upstream protection at the corresponding input voltage, separately from output current.

A stirrer motor turns a magnet beneath the vessel to move the stir bar. For a 24 V DC motor controller, compare loaded starting current with MDR-60-24 (0–2.5 A). A hotplate heater is not part of that motor branch.
Photo: User:Ruhrfisch · CC BY-SA 3.0
At a light tent, separately driven lamps soften shadows around small objects. For lamps with 12 V DC driver inputs, add their full-brightness and startup demand before selecting MDR-60-12 (0–5 A). Do not substitute DC for mains lamps.
Photo: Alison Christine from North Yorkshire, UK · CC BY 2.0
In a meter fitted with a 12 V DC coin validator, the reader checks each coin before credit is recorded. Compare peak current, including the reject mechanism, with MDR-60-12 (0–5 A); the printer and outdoor enclosure need separate checks.
Photo: Parking Ticket Machine on St Petersgate by Gerald England · CC BY-SA 2.0
The switch forwards data between wired devices. For a switch with a specified 12 V DC input, compare its maximum draw with MDR-60-12 (0–5 A). The computer is a separate load; Ethernet ports alone do not imply PoE.
Photo: RAIL P ( RAIL.PHOTOGRAPHY ) · CC0 1.0These photographs show examples of low-voltage loads, not verified MDR-60 installations or endorsements. Check the actual component’s input specification before selecting a supply.
No. Each column identifies a separate single-output version. For example, MDR-60-12 is the 12 V model and MDR-60-24 is the 24 V model. The trim adjustment is not a voltage selector.
MDR-60-24 is specified at 0–2.5 A. Include simultaneous loads and startup demand when sizing the branch.
The MDR-60 datasheet specifies 85–264 VAC and 120–370 VDC. The 47–63 Hz frequency range applies to AC.
The housing measures 40 × 90 × 100 mm. The manufacturer drawing lists TS35/7.5 or TS35/15; reserve extra space for cable access.
The DC OK relay reports output status. Its resistive-contact rating is not the supply output rating.
No. The sheet lists −10 °C to +50 °C as the working range; it does not establish full load at every ambient temperature. Check the actual enclosure conditions.
Overload cuts off output with automatic recovery. Overvoltage shuts down the output; cycle input power after the fault is cleared.
500 / 30 ms at 230 VAC; 500 / 30 ms at 115 VAC. These are full-load setup and rise times. No separate hold-up value is printed.
30 A at 115 VAC; 60 A at 230 VAC are the two cold-start input conditions. Coordinate upstream protection for the actual input and number of supplies starting together.
MDR-60-12 lists 120 mV p-p. Check the ripple tolerance at the load as well as the DC current requirement.
Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV. These one-minute withstand figures are not continuous operating voltages.
Give the full MDR-60 suffix, DC load and startup demand, installed rail and available space. A match in family wattage or cabinet width does not establish interchangeability.



This view shows MDR-60-12; the photographed unit does not change when another output is selected. Electrical specifications follow the MDR-60 datasheet.

A crop of the pictured specimen for identification, not a separate specification source.

Width and height are dimensioned on the front view.

Depth is dimensioned on the side view; it does not include field wiring.

Rail profile from the model sheet. Mounting types: TS35/7.5 and TS35/15.
Tell us how many units you need and where they will be delivered.