Check the panel space
Allow 105 × 90 × 54.5 mm for the body. The drawing lists TS35/7.5 or TS35/15. Check cable bends and access separately; the body depth is not the installed clearance.
WEHO’s HDR-150 is a compact, single-output DIN-rail power-supply family for panel-mounted control, sensing and communications electronics. Separate 12V, 15V, 24V, 48V versions support voltage-specific selection, while the 105×90×54.5mm body gives a defined mechanical envelope. Match the selected model’s current rating and actual installation conditions before ordering.
यदि आपके कोई प्रश्न हैं, तो कृपया हमसे संपर्क करने में संकोच न करें ईमेल: [email protected]
Choose an output voltage, then check its current range at the applicable AC input.
| Parameter | HDR-150-12 | HDR-150-15 | HDR-150-24 | HDR-150-48 |
|---|---|---|---|---|
| DC output voltage and current | 12 V · 0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC | 15 V · 0 to 8.55 A at 115 VAC; 0 to 9.5 A at 230 VAC | 24 V · 0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC | 48 V · 0 to 2.72 A at 115 VAC; 0 to 3.2 A at 230 VAC |
| क्षमता | 87% | 88% | 89% | 89% |
| Ripple and noise | 100 mV p-p | 120 mV p-p | 150 mV p-p | 200 mV p-p |
| रेखा विनियमन | ±1% | ±1% | ±1% | ±1% |
| लोड विनियमन | ±1% | ±1% | ±1% | ±1% |
| DC voltage adjustment | ±10% | ±10% | ±10% | ±10% |
| AC input | 85 to 264 VAC | |||
| DC input | 120 to 370 VDC | |||
| Dimensions (W × H × D) | 105 × 90 × 54.5 mm | |||
| Input frequency | 47 to 63 Hz | |||
| Cold-start inrush | 35 A at 115 VAC; 70 A at 230 VAC | |||
| अधिभार संरक्षण | 105% to 150%: output shuts off; automatic recovery. | |||
| ओवरवॉल्टेज संरक्षण | 115%~140% rated output power. Hiccup mode; automatic recovery when the fault is removed. The source does not specify a voltage trip threshold. | |||
| Setup / rise time | 1500 ms / 80 ms at both 115 VAC and 230 VAC, full load. Hold-up time is unspecified. | |||
| वोल्टेज का सामना करें | Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV (1 min). | |||
| इन्सुलेशन प्रतिरोध | 100 MΩ at 500 VDC, 25 °C, 70% RH: input/output, input/FG, output/FG | |||
| कार्य तापमान | -20 °C to +70 °C | |||
| Unit weight | 0.3 kg | |||
| पैकिंग | Not specified. | |||
| नमूना | उत्पादन | मौजूदा | क्षमता |
|---|---|---|---|
| HDR-150-12 | 12 V | 0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC | 87% |
| HDR-150-15 | 15 V | 0 to 8.55 A at 115 VAC; 0 to 9.5 A at 230 VAC | 88% |
| HDR-150-24 | 24 V | 0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC | 89% |
| HDR-150-48 | 48 V | 0 to 2.72 A at 115 VAC; 0 to 3.2 A at 230 VAC | 89% |
| Ripple and noise | 100 mV p-p |
|---|---|
| रेखा विनियमन | ±1% |
| लोड विनियमन | ±1% |
| DC voltage adjustment | ±10% |
| Ripple and noise | 120 mV p-p |
|---|---|
| रेखा विनियमन | ±1% |
| लोड विनियमन | ±1% |
| DC voltage adjustment | ±10% |
| Ripple and noise | 150 mV p-p |
|---|---|
| रेखा विनियमन | ±1% |
| लोड विनियमन | ±1% |
| DC voltage adjustment | ±10% |
| Ripple and noise | 200 mV p-p |
|---|---|
| रेखा विनियमन | ±1% |
| लोड विनियमन | ±1% |
| DC voltage adjustment | ±10% |
| AC input | 85 to 264 VAC |
|---|---|
| DC input | 120 to 370 VDC |
| Dimensions (W × H × D) | 105 × 90 × 54.5 mm |
| Input frequency | 47 to 63 Hz |
| Cold-start inrush | 35 A at 115 VAC; 70 A at 230 VAC |
| अधिभार संरक्षण | 105% to 150%: output shuts off; automatic recovery. |
| ओवरवॉल्टेज संरक्षण | 115%~140% rated output power. Hiccup mode; automatic recovery when the fault is removed. The source does not specify a voltage trip threshold. |
| Setup / rise time | 1500 ms / 80 ms at both 115 VAC and 230 VAC, full load. Hold-up time is unspecified. |
| वोल्टेज का सामना करें | Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV (1 min). |
| इन्सुलेशन प्रतिरोध | 100 MΩ at 500 VDC, 25 °C, 70% RH: input/output, input/FG, output/FG |
| कार्य तापमान | -20 °C to +70 °C |
| Unit weight | 0.3 kg |
| पैकिंग | Not specified. |
105 × 90 × 54.5 mm
Front elevation with terminal numbers; specimen nameplate print omitted.
Side elevation with separate body and extended depth dimensions.
Rail profile detail showing the dimensioned 35 mm rail.
Terminal assignments: Pin 1: AC/N; Pin 2: AC/L; Pin 3, 4: -V; Pin 5, 6: +V.
Mounting rail: TS35/7.5 or TS35/15.
Body depth and extended depth are measured to different reference lines on the side view. The drawing is not installation CAD.
HDR-150 is a 150 W family of single-output DIN rail supplies. The family designation is not a separate power rating for each output. Use the voltage, current range and operating conditions for the exact suffix.
| विशेषता | What to check |
|---|---|
| Defined mechanical envelope | Allow for the 105 × 90 × 54.5 mm enclosure, then add room for cable bends and access to the terminals. |
| Distinct single-output versions | The available outputs are 12 V, 15 V, 24 V, 48 V. Select one version; these are not simultaneous outputs. |
| Documented input coverage | 85 to 264 VAC or 120 to 370 VDC. The AC frequency range is 47 to 63 Hz. |
| Defined overload recovery | 105% to 150%: output shuts off; automatic recovery. Do not use the protection threshold as a continuous rating. |
The current table has separate 115 VAC and 230 VAC rows. Do not apply the higher figure across the full input range.

Allow 105 × 90 × 54.5 mm for the body. The drawing lists TS35/7.5 or TS35/15. Check cable bends and access separately; the body depth is not the installed clearance.

With power isolated, identify the terminals on the exact unit and drawing. Pin 1: AC/N; Pin 2: AC/L; Pin 3, 4: -V; Pin 5, 6: +V. Do not infer DC input polarity from the AC labels.

Check the air around the supply with the panel in its normal operating state. The stated working range is -20 °C to +70 °C; it is not a promise of full load at the upper limit.

The datasheet gives 35 A at 115 VAC; 70 A at 230 VAC for cold start. Check the upstream protection against the applicable input condition. Check the DC load’s start-up demand separately.

An approach detector above a sliding entrance signals the door operator. Size only the detector branch, including all heads that share it. For a compatible 24 VDC version, check running and start-up current against HDR-150-24 (0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC). The motor and monitored safety circuits must follow the door manufacturer’s approved design.
Photo: Secondarywaltz · CC BY-SA 4.0 · WebP edition
At a book-scanning bench, a proof monitor lets the operator check page alignment before turning the leaf. Size its separate DC feed. For a compatible 12 VDC version, check running and start-up current against HDR-150-12 (0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC). Do not include the capture computer or assume that every monitor uses the same adapter.
Photo: Dvortygirl · CC BY-SA 4.0 · Cropped and converted to WebP
For routine match announcements, size the DC input of an active horn or its local amplifier. Sum the demand of all active channels on the branch. For a compatible 24 VDC version, check running and start-up current against HDR-150-24 (0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC). Never feed DC into passive loudspeaker terminals. This example does not cover emergency voice systems.
Photo: W.carter · CC0 · WebP edition
A platform information panel presents the next departure. In a modular system, size the separately powered display section, not the station network. For a compatible 24 VDC version, check running and start-up current against HDR-150-24 (0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC). Use the supplier’s maximum-brightness input figure and verify peak demand for all sections on the rail.
Photo: PPP · CC BY-SA 4.0 · Cropped and converted to WebPScenes show the application equipment, not a verified HDR installation. Each example applies only to a load with the specified DC input; the photographs do not establish its rating.
The sheet lists HDR-150-12, HDR-150-15, HDR-150-24, HDR-150-48, in that order. Each is a separate single-output version.
HDR-150-12: 0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC; HDR-150-15: 0 to 8.55 A at 115 VAC; 0 to 9.5 A at 230 VAC; HDR-150-24: 0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC; HDR-150-48: 0 to 2.72 A at 115 VAC; 0 to 3.2 A at 230 VAC. Keep the two AC input conditions separate; there is no unconditional current ceiling in this table.
85 to 264 VAC or 120 to 370 VDC. The AC frequency range is 47 to 63 Hz.
Line regulation is ±1% and load regulation is ±1% for each listed output.
The specified adjustment range is ±10% for each version. Check the load's allowable input before adjusting.
HDR-150-12: 100 mV p-p; HDR-150-15: 120 mV p-p; HDR-150-24: 150 mV p-p; HDR-150-48: 200 mV p-p.
HDR-150-12: 87%; HDR-150-15: 88%; HDR-150-24: 89%; HDR-150-48: 89%.
35 A at 115 VAC; 70 A at 230 VAC. These are input inrush values, not output-current ratings.
105% to 150%: output shuts off; automatic recovery. Do not use the protection threshold as a continuous rating.
1500 ms / 80 ms at both 115 VAC and 230 VAC, full load. The sheet does not give a separate hold-up time.
Working temperature: -20 °C to +70 °C. Body dimensions (W × H × D): 105 × 90 × 54.5 mm. Weight: 0.3 kg. Full load is not specified throughout the temperature range.
Pin 1: AC/N; Pin 2: AC/L; Pin 3, 4: -V; Pin 5, 6: +V. Mounting rail: TS35/7.5 or TS35/15. Use the drawing for this model.
Plan around the 105 × 90 × 54.5 mm body and 0.3 kg unit weight. Allow room for access as well as the rail itself.
Check the source against 85 to 264 VAC or 120 to 370 VDC. Pin 1: AC/N; Pin 2: AC/L; Pin 3, 4: -V; Pin 5, 6: +V. AC terminal letters alone do not establish DC input polarity.
The stated working range is -20 °C to +70 °C. Check the local air temperature and actual load in the closed panel; the upper limit is not a full-load rating.
Cold-start input inrush: 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time: 1500 ms / 80 ms at both 115 VAC and 230 VAC, full load. Check load start-up separately.



The photograph identifies the HDR-150-24 specimen. It remains the same when a different output is selected; ratings come from the WEHO datasheet.

HDR-150-24 with a short rail. This image identifies the pictured specimen only.

The opposite three-quarter view of an HDR-150-24 specimen.

Detail from the HDR-150-24 product photograph, not an additional sample. Use the English sheet for electrical specifications.
Front elevation with terminal numbers; specimen nameplate print omitted.
Side elevation with separate body and extended depth dimensions.
Rail profile detail showing the dimensioned 35 mm rail.
Tell us how many units you need and where they will be delivered.

WEHO गुणवत्ता वाले बिजली आपूर्ति उत्पादों के साथ अपने व्यवसाय को बढ़ावा दें।.
किसी विशेषज्ञ से पूछें