Slim Size HDR-150 150W Din Rail Switching Power Supply

WEHO’s HDR-150 is a compact, single-output DIN-rail power-supply family for panel-mounted control, sensing and communications electronics. Separate 12V, 15V, 24V, 48V versions support voltage-specific selection, while the 105×90×54.5mm body gives a defined mechanical envelope. Match the selected model’s current rating and actual installation conditions before ordering.

Если у вас есть какие-либо вопросы, пожалуйста, не стесняйтесь обращаться к нам по адресу Электронная почта: [email protected]

HDR-150-24 specimen

HDR-150 Single-Output DIN Rail Power Supply

Choose an output voltage, then check its current range at the applicable AC input.

Select output voltage
Модель
HDR-150-12HDR-150-15HDR-150-24HDR-150-48
DC output
12 V · 0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC15 V · 0 to 8.55 A at 115 VAC; 0 to 9.5 A at 230 VAC24 V · 0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC48 V · 0 to 2.72 A at 115 VAC; 0 to 3.2 A at 230 VAC
AC input
85 to 264 VAC
DC input
120 to 370 VDC
Эффективность
87%88%89%89%
Dimensions (W × H × D)
105 × 90 × 54.5 mm

Specifications & models

ПараметрHDR-150-12HDR-150-15HDR-150-24HDR-150-48
DC output voltage and current12 V · 0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC15 V · 0 to 8.55 A at 115 VAC; 0 to 9.5 A at 230 VAC24 V · 0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC48 V · 0 to 2.72 A at 115 VAC; 0 to 3.2 A at 230 VAC
Эффективность87%88%89%89%
Ripple и шум100 mV p-p120 mV p-p150 mV p-p200 mV p-p
Регулирование линии±1%±1%±1%±1%
Регулирование нагрузки±1%±1%±1%±1%
DC voltage adjustment±10%±10%±10%±10%
AC input85 to 264 VAC
DC input120 to 370 VDC
Dimensions (W × H × D)105 × 90 × 54.5 mm
Input frequency47 to 63 Hz
Cold-start inrush35 A at 115 VAC; 70 A at 230 VAC
Защита от перегрузки105% to 150%: output shuts off; automatic recovery.
Защита от перенапряжения115%~140% rated output power. Hiccup mode; automatic recovery when the fault is removed. The source does not specify a voltage trip threshold.
Setup / rise time1500 ms / 80 ms at both 115 VAC and 230 VAC, full load. Hold-up time is unspecified.
Выдерживая напряжениеInput/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV (1 min).
Устойчивость к изоляции100 MΩ at 500 VDC, 25 °C, 70% RH: input/output, input/FG, output/FG
Рабочая температура-20 °C to +70 °C
Unit weight0.3 kg
УпаковкаNot specified.
Output options
МодельВыходТекущийЭффективность
HDR-150-1212 V0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC87%
HDR-150-1515 V0 to 8.55 A at 115 VAC; 0 to 9.5 A at 230 VAC88%
HDR-150-2424 V0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC89%
HDR-150-4848 V0 to 2.72 A at 115 VAC; 0 to 3.2 A at 230 VAC89%
Additional model specifications
HDR-150-12
Ripple и шум100 mV p-p
Регулирование линии±1%
Регулирование нагрузки±1%
DC voltage adjustment±10%
HDR-150-15
Ripple и шум120 mV p-p
Регулирование линии±1%
Регулирование нагрузки±1%
DC voltage adjustment±10%
HDR-150-24
Ripple и шум150 mV p-p
Регулирование линии±1%
Регулирование нагрузки±1%
DC voltage adjustment±10%
HDR-150-48
Ripple и шум200 mV p-p
Регулирование линии±1%
Регулирование нагрузки±1%
DC voltage adjustment±10%
Common specifications
AC input85 to 264 VAC
DC input120 to 370 VDC
Dimensions (W × H × D)105 × 90 × 54.5 mm
Input frequency47 to 63 Hz
Cold-start inrush35 A at 115 VAC; 70 A at 230 VAC
Защита от перегрузки105% to 150%: output shuts off; automatic recovery.
Защита от перенапряжения115%~140% rated output power. Hiccup mode; automatic recovery when the fault is removed. The source does not specify a voltage trip threshold.
Setup / rise time1500 ms / 80 ms at both 115 VAC and 230 VAC, full load. Hold-up time is unspecified.
Выдерживая напряжениеInput/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV (1 min).
Устойчивость к изоляции100 MΩ at 500 VDC, 25 °C, 70% RH: input/output, input/FG, output/FG
Рабочая температура-20 °C to +70 °C
Unit weight0.3 kg
УпаковкаNot specified.

Dimensions & technical notes

Mechanical dimensions

105 × 90 × 54.5 mm

Front view
HDR-150 · Front elevation with terminal numbers; specimen nameplate print omitted.

Front elevation with terminal numbers; specimen nameplate print omitted.

Side view
HDR-150 · Side elevation with separate body and extended depth dimensions.

Side elevation with separate body and extended depth dimensions.

Rail view
HDR-150 · Rail profile detail showing the dimensioned 35 mm rail.

Rail profile detail showing the dimensioned 35 mm rail.

Terminal assignments: Pin 1: AC/N; Pin 2: AC/L; Pin 3, 4: -V; Pin 5, 6: +V.

Mounting rail: TS35/7.5 or TS35/15.

Body depth and extended depth are measured to different reference lines on the side view. The drawing is not installation CAD.

Product overview

HDR-150 is a 150 W family of single-output DIN rail supplies. The family designation is not a separate power rating for each output. Use the voltage, current range and operating conditions for the exact suffix.

Design features

ОсобенностьWhat to check
Defined mechanical envelopeAllow for the 105 × 90 × 54.5 mm enclosure, then add room for cable bends and access to the terminals.
Distinct single-output versionsThe available outputs are 12 V, 15 V, 24 V, 48 V. Select one version; these are not simultaneous outputs.
Documented input coverage85 to 264 VAC or 120 to 370 VDC. The AC frequency range is 47 to 63 Hz.
Defined overload recovery105% to 150%: output shuts off; automatic recovery. Do not use the protection threshold as a continuous rating.

The current table has separate 115 VAC and 230 VAC rows. Do not apply the higher figure across the full input range.

Installation & applications

Installation checks

HDR-150 side elevation and body dimensions.

Check the panel space

Allow 105 × 90 × 54.5 mm for the body. The drawing lists TS35/7.5 or TS35/15. Check cable bends and access separately; the body depth is not the installed clearance.

HDR-150 front elevation with its numbered terminal key.

Identify the input and output

With power isolated, identify the terminals on the exact unit and drawing. Pin 1: AC/N; Pin 2: AC/L; Pin 3, 4: -V; Pin 5, 6: +V. Do not infer DC input polarity from the AC labels.

Illustration of a closed panel beside an ambient probe and a separate wall grille; no reading is shown.

Check the enclosure temperature

Check the air around the supply with the panel in its normal operating state. The stated working range is -20 °C to +70 °C; it is not a promise of full load at the upper limit.

HDR-150 cold-start input inrush: 35 A at 115 VAC; 70 A at 230 VAC.

Coordinate cold-start inrush

The datasheet gives 35 A at 115 VAC; 70 A at 230 VAC for cold start. Check the upstream protection against the applicable input condition. Check the DC load’s start-up demand separately.

Application examples

Two sliding entrance leaves stand open below a small overhead detector.

Automatic entrance activation

An approach detector above a sliding entrance signals the door operator. Size only the detector branch, including all heads that share it. For a compatible 24 VDC version, check running and start-up current against HDR-150-24 (0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC). The motor and monitored safety circuits must follow the door manufacturer’s approved design.

Photo: Secondarywaltz · CC BY-SA 4.0 · WebP edition
An open book rests in an angled scanning cradle with proofing monitors at the bench.

Book digitisation workstation

At a book-scanning bench, a proof monitor lets the operator check page alignment before turning the leaf. Size its separate DC feed. For a compatible 12 VDC version, check running and start-up current against HDR-150-12 (0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC). Do not include the capture computer or assume that every monitor uses the same adapter.

Photo: Dvortygirl · CC BY-SA 4.0 · Cropped and converted to WebP
Three horn loudspeakers face different parts of the ground from a metal mast.

Sports-ground announcements

For routine match announcements, size the DC input of an active horn or its local amplifier. Sum the demand of all active channels on the branch. For a compatible 24 VDC version, check running and start-up current against HDR-150-24 (0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC). Never feed DC into passive loudspeaker terminals. This example does not cover emergency voice systems.

Photo: W.carter · CC0 · WebP edition
A suspended platform board shows a destination, departure time and platform number beside a clock.

Platform departure information

A platform information panel presents the next departure. In a modular system, size the separately powered display section, not the station network. For a compatible 24 VDC version, check running and start-up current against HDR-150-24 (0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC). Use the supplier’s maximum-brightness input figure and verify peak demand for all sections on the rail.

Photo: PPP · CC BY-SA 4.0 · Cropped and converted to WebP

Scenes show the application equipment, not a verified HDR installation. Each example applies only to a load with the specified DC input; the photographs do not establish its rating.

Часто задаваемые вопросы

Which DC output models are listed for HDR-150?

The sheet lists HDR-150-12, HDR-150-15, HDR-150-24, HDR-150-48, in that order. Each is a separate single-output version.

What current ratings are listed for HDR-150?

HDR-150-12: 0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC; HDR-150-15: 0 to 8.55 A at 115 VAC; 0 to 9.5 A at 230 VAC; HDR-150-24: 0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC; HDR-150-48: 0 to 2.72 A at 115 VAC; 0 to 3.2 A at 230 VAC. Keep the two AC input conditions separate; there is no unconditional current ceiling in this table.

What input-voltage and frequency ranges are specified?

85 to 264 VAC or 120 to 370 VDC. The AC frequency range is 47 to 63 Hz.

What line-regulation and load-regulation figures are listed?

Line regulation is ±1% and load regulation is ±1% for each listed output.

What DC voltage adjustment range is listed?

The specified adjustment range is ±10% for each version. Check the load's allowable input before adjusting.

What ripple/noise values are listed for HDR-150?

HDR-150-12: 100 mV p-p; HDR-150-15: 120 mV p-p; HDR-150-24: 150 mV p-p; HDR-150-48: 200 mV p-p.

What efficiency values are listed for HDR-150?

HDR-150-12: 87%; HDR-150-15: 88%; HDR-150-24: 89%; HDR-150-48: 89%.

What cold-start current is specified?

35 A at 115 VAC; 70 A at 230 VAC. These are input inrush values, not output-current ratings.

How is overload recovery specified?

105% to 150%: output shuts off; automatic recovery. Do not use the protection threshold as a continuous rating.

What timing information is provided?

1500 ms / 80 ms at both 115 VAC and 230 VAC, full load. The sheet does not give a separate hold-up time.

What working-temperature range and dimensions are stated for HDR-150?

Working temperature: -20 °C to +70 °C. Body dimensions (W × H × D): 105 × 90 × 54.5 mm. Weight: 0.3 kg. Full load is not specified throughout the temperature range.

Which terminal assignments are shown for HDR-150?

Pin 1: AC/N; Pin 2: AC/L; Pin 3, 4: -V; Pin 5, 6: +V. Mounting rail: TS35/7.5 or TS35/15. Use the drawing for this model.

Service conditions

Panel space and mechanical fit

Plan around the 105 × 90 × 54.5 mm body and 0.3 kg unit weight. Allow room for access as well as the rail itself.

Input and terminal checks

Check the source against 85 to 264 VAC or 120 to 370 VDC. Pin 1: AC/N; Pin 2: AC/L; Pin 3, 4: -V; Pin 5, 6: +V. AC terminal letters alone do not establish DC input polarity.

Temperature and load planning

The stated working range is -20 °C to +70 °C. Check the local air temperature and actual load in the closed panel; the upper limit is not a full-load rating.

Start-up and fault coordination

Cold-start input inrush: 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time: 1500 ms / 80 ms at both 115 VAC and 230 VAC, full load. Check load start-up separately.

Send Inquiry

Tell us how many units you need and where they will be delivered.

WEHO HDR-150-24 specimen in three-quarter view.
HDR-150-24 specimen
Selected model
HDR-150-12HDR-150-15HDR-150-24HDR-150-48
DC output
12 V · 0 to 10.2 A at 115 VAC; 0 to 11.3 A at 230 VAC15 V · 0 to 8.55 A at 115 VAC; 0 to 9.5 A at 230 VAC24 V · 0 to 5.31 A at 115 VAC; 0 to 6.25 A at 230 VAC48 V · 0 to 2.72 A at 115 VAC; 0 to 3.2 A at 230 VAC