LRS-50 Series 50W Single Output Enclosed Switching Power Supply (LRS-50-12 / LRS-50-24)
• Input: 85-264VAC or 120-373VDC, 47-63Hz
• 50W-class single-output family with 12V, 15V, 24V and 48V versions
• Output-current ranges: 0-4.2A, 0-3.4A, 0-2.2A and 0-1.1A respectively
• Listed efficiencies: 86%, 88%, 88% and 90% in the same voltage order
• Adjustable DC output voltage: ±10%
• Overload protection: 110-150%, cut off the output with automatic recovery
• Overcurrent and short-circuit protection
• Working temperature: -20℃ to +70℃
• Withstand voltage: I/P-O/P 1.5kV, I/P-FG 1.5kV, O/P-FG 0.5kV, 1 minute
• Enclosure: 99×82×30mm; weight 0.23kg
- Opis
Overview
The LRS-50 is an enclosed single-output power supply for proposed integration into compact document-processing and interactive equipment. The LRS-50 specification lists LRS-50-12, LRS-50-15, LRS-50-24, LRS-50-48. Its small housing is useful where paper paths, displays and maintenance access compete for space. Provide the output version and a measured load profile to focus the selection review.
Why Choose LRS-50?
Fit behind compact equipment mechanisms
The LRS-50 dimensions are 99×82×30mm. Use the stated body size to plan the equipment compartment, then allocate additional wiring and service space.
Choose a dedicated electronics rail
The documented output choices are 12V 0~4.2A; 15V 0~3.4A; 24V 0~2.2A; 48V 0~1.1A. Match the equipment voltage first so the selected version serves a defined DC rail rather than a collection of incompatible loads.
Compare losses by output version
The efficiency entries are LRS-50-12: 86%; LRS-50-15: 88%; LRS-50-24: 88%; LRS-50-48: 90%. Compare the selected version when budgeting conversion losses rather than assigning the best figure to every rail.
Select within documented operating limits
Overload protection is specified as 110%–150%, with output cut-off and automatic recovery. Coordinate the host restart sequence and real peripheral demand around that stated response.
Features, Benefits & Advantages
| Funkcja | Benefit in equipment design |
|---|---|
| Single-output choices for compact devices | The output table lists 12V 0~4.2A; 15V 0~3.4A; 24V 0~2.2A; 48V 0~1.1A. Use the selected output column as the starting point for the connected-device budget. |
| Line and load regulation for interface rails | Line regulation and load regulation are each ±0.5%. The wave-and-noise figures are 120mVp-p, 120mVp-p, 150mVp-p, 200mVp-p for the output columns in the listed order. Compare these figures with the electronics tolerance and any required downstream filtering. |
| Adjustable output for commissioning | The DC-voltage adjustment range is ±10%. Set the output only within the connected equipment limits, and check voltage at the load under representative demand. |
| Abnormal-load response stated explicitly | The source lists overload, overcurrent and short-circuit protection. The overload response is output cut-off and automatic recovery at the stated 110%–150% range. This response helps define host fault handling; it is not extra continuous load capacity. |
Mechanical dimensions
| Body length | 99 mm |
|---|---|
| Body width | 82 mm |
| Body height | 30 mm |
The body dimensions and mounting-hole dimensions are different references. The vector drawing below retains the dimensions printed in the WEHO original.
On a small screen, swipe the drawing horizontally to inspect every dimension. No separate drawing image or script download is required.
Load derating
Apply these model-specific curves only within the stated WEHO operating range of -20 to +70 °C and the input range in the specification table. A reference axis extending below that range does not extend the product rating. Follow the input-voltage and mounting-orientation labels shown on each curve.
View the functional block diagram
Specifications & Model
| Specyfikacja | LRS-50-12 | LRS-50-15 | LRS-50-24 | LRS-50-48 |
| Napięcie wyjściowe DC, prąd | 12 V 0 ~ 4,2 A | 15V 0~3.4A | 24 V 0 ~ 2,2 A | 48 V 0 ~ 1,1 A |
| Fala i hałas | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p |
| Stabilność przewodu wlotowego | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Stabilność obciążenia | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Efektywność | 86% | 88% | 88% | 90% |
| Regulowany zakres napięcia stałego | ±10% | ±10% | ±10% | ±10% |
| Zakres napięcia wejściowego | 85~264VAC / 120~373VDC, 47~63Hz | |||
| Prąd udarowy | Prąd zimnego rozruchu 45A/230VAC | |||
| Zabezpieczenie przed przeciążeniem | 110%~150% cut off the output, automatic recovery | |||
| Inna ochrona | Overcurrent protection / Short-circuit protection | |||
| Timing (setup / rise / hold-up) | 230VAC: 1000ms, 30ms; 115VAC: 2000ms, 30ms. No separate hold-up time is specified. | |||
| Wytrzymuje napięcie | I/P-O/P: 1,5 kV I/P-FG: 1,5 kV O/P-FG: 0,5 kV 1 minuta | |||
| Rezystancja izolacji | I/P-O/P I/P-FG O/P-FG: 100M omów/500VDC/25℃/70%RH | |||
| Temperatura pracy | -20 ℃ ~ + 70 ℃ | |||
| Wymiar | 99×82×30mm | |||
| Waga | 0,23 kg | |||
| Uszczelka | 44×36,5×19,5 cm/80 szt./16 kg | |||
Typical Service Conditions
AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.
Input matching: LRS-50 versus the selector example
The illustration shows the LRS-350 manual-range example; do not transfer its 90–132/180–264 VAC bands to LRS-50. The LRS-50 input range is 85–264VAC or 120–373VDC; the table lists 47–63Hz. Check the actual incoming supply and the complete input-protection arrangement before commissioning. Match the selected DC version to every connected input, then include simultaneous demand and startup transients before energising the equipment. The planning image is a representative LRS-series example, not an exact-model wiring diagram.
LRS-350 manual-selector planning example; use LRS-50 input bands, selection instructions and output options, not the example labels.
LRS-50 enclosure and service-space planning
The printed dimensions are 99×82×30mm and the weight is 0.23kg. Reserve additional space for wiring, access and the host ventilation arrangement; the body dimensions are not installation clearances. Reserve additional space for terminal access, conductor routing and the host equipment's airflow; the case outline is not a clearance allowance.
LRS-series cabinet-space concept; the exact case, cooling method and mounting are defined by this model's own technical data.
Temperature and duty-cycle assessment for LRS-50
The specified working-temperature range is -20°C to +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. Measure the temperature at the installed supply and review the longest expected duty cycle. Keep vents unobstructed; do not substitute room temperature for the operating temperature inside the equipment.
LRS-350 temperature-planning example, not a measured derating curve or a replacement for LRS-50 operating limits.
LRS-50 fault recovery and protected installation
Overload protection is 110%–150%, with output cut-off and automatic recovery; overcurrent and short-circuit protection are also listed. Coordinate the host fault response and branch protection with real load behavior; automatic recovery is not a redundancy or backup function. Have a qualified installer check terminal identification, protective earthing and branch protection for the actual assembly. Coordinate restart behaviour with the equipment controls rather than treating supply recovery as a safety function.
Functional power-planning illustration only; follow the exact model's terminal identification and qualified installation instructions.
Application Industries
AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.
Retail sign-control and LED-module branches
Inside a compact retail display, assess LRS-50 for a compatible lighting-control board or a separately protected LED-module branch. Budget the selected output against the actual module current, and use a suitable driver wherever current regulation is needed. The unit remains in a dry, protected equipment space.
Proposed output: LRS-50-24, with the printed output entry 24V 0~2.2A.
AI application concept — retail signage, not an installation record for this product.
Parcel-terminal interface electronics
A small parcel-terminal controller can be evaluated separately from its display and lock bank. An LRS-50 branch is conditional on matched input voltage and the combined demand of the controller and status sensors; do not assume that every door lock can energise at once.
Proposed output: LRS-50-12, with the printed output entry 12V 0~4.2A.
AI application concept — parcel-terminal electronics, not an installation record for this product.
Carton-packaging auxiliary electronics
For a carton magazine, consider LRS-50 for compatible blank-presence sensors and their interface electronics. Include simultaneous indication and sensor startup in the branch budget. The forming actuator, conveyor and emergency-stop functions retain their separately designed power arrangements.
Proposed output: LRS-50-24, with the printed output entry 24V 0~2.2A.
AI application concept — carton-packaging auxiliary electronics, not a complete-machine power claim.
Electronics-fixture auxiliary interfaces
An electronics fixture may use LRS-50 for its local controller, detection inputs and status lamps where their inputs match the selected version. Keep DUT stimulus and measurement supplies separate. Check noise at the load with the actual fixture wiring rather than inferring measurement accuracy from the supply.
Proposed output: LRS-50-12, with the printed output entry 12V 0~4.2A.
AI application concept — electronics-fixture interfaces; no measurement-performance or installed-model claim.
Często zadawane pytania
What DC output options does the LRS-50 specification list?
The listed versions are LRS-50-12: 12V 0~4.2A; LRS-50-15: 15V 0~3.4A; LRS-50-24: 24V 0~2.2A; LRS-50-48: 48V 0~1.1A. Each is a separate output choice, not a simultaneous multi-output rail set.
What input range does the LRS-50 require?
The LRS-50 input range is 85–264VAC or 120–373VDC; the table lists 47–63Hz. Check the actual incoming supply and the complete input-protection arrangement before commissioning.
How does the LRS-50 series power statement relate to its output-current table?
The manufacturer summary states “Single output: power 50W”. Its separate output table lists 12V 0~4.2A; 15V 0~3.4A; 24V 0~2.2A; 48V 0~1.1A. The sheet does not provide a separate per-version continuous-power row; the series statement and current endpoints remain separate source statements rather than a recalculated continuous rating. Confirm the selected version against the intended continuous and transient load profile without treating the current endpoint as an independently proven continuous-power rating.
What output adjustment does the LRS-50 provide?
The specified DC-voltage adjustment is ±10%. Match the final setting to the connected device limits; adjustment does not turn a selected version into every other output version.
What regulation and wave-and-noise figures does the LRS-50 list?
Line and load regulation are each ±0.5%. Wave and noise are LRS-50-12: 120mVp-p; LRS-50-15: 120mVp-p; LRS-50-24: 150mVp-p; LRS-50-48: 200mVp-p. Compare the load tolerance and measurement arrangement before deciding whether local filtering is needed.
What efficiency figures does the LRS-50 specify?
The efficiency entries are LRS-50-12: 86%; LRS-50-15: 88%; LRS-50-24: 88%; LRS-50-48: 90%. These column-specific figures support loss comparison, not an all-load efficiency guarantee.
What protection response does the LRS-50 document?
Overload protection is 110%–150%, with output cut-off and automatic recovery; overcurrent and short-circuit protection are also listed. Coordinate the host fault response and branch protection with real load behavior; automatic recovery is not a redundancy or backup function.
What input-starting current does the LRS-50 specify?
The inrush entry is “Cold start current 45A/230VAC”. Include input-starting behavior when selecting upstream switching and protection; this is not the DC output-current rating.
What timing values does the LRS-50 actually provide?
Under “Setup, rise, hold up time”, the printed entry is “1000ms,30ms/230VAC 2000ms,30ms/115VAC”. Only the printed time pairs are available; no separate hold-up value or at-full-load condition is stated. An interruption-sensitive controller therefore needs a system-level restart or ride-through assessment, not an assumed hold-up duration.
What temperature and cooling boundaries apply to the LRS-50?
The specified working-temperature range is -20°C to +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. The operating interval alone is not a promise of full output at every temperature. Assess mounting, airflow, actual load and temperature in the finished equipment; the reference curve does not expand the WEHO model's stated operating or output ratings.
What size and weight does the LRS-50 list?
The printed dimensions are 99×82×30mm and the weight is 0.23kg. Reserve additional space for wiring, access and the host ventilation arrangement; the body dimensions are not installation clearances.
What withstand and isolation entries does the LRS-50 provide?
The withstand entry is “I/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute”. The isolation-resistance entry is “I/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH”. These are the source test entries, not proof of a product certification or the compliance of the completed equipment.