| Модель | T-60A | T-60B | T-60C | T-60D | ||||||||
| CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
| Выходное напряжение постоянного тока | 5В | 12 В | -5V | 5В | 12 В | -12V | 5В | 15 В | -15V | 5В | 12 В | 24 (unit not printed; verification required) |
| Output voltage tolerance (not separately stated) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Rated output current (not separately stated) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Output current range (as printed) | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 0.5A | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 0.5A | 0 ~ 5A | 0 ~ 2A | 0 ~ 0.5A | 0.5 ~ 5A | 0.2 ~ 2.5A | 0.2 ~ 0.5A |
| Волна и шум | 50mVp-p | 100 мВпик-пик | 100 мВпик-пик | 100 мВпик-пик | 120 мВ (пик-пик) | 120 мВ (пик-пик) | 100 мВпик-пик | 120 мВ (пик-пик) | 120 мВ (пик-пик) | 80мВпик-пик | 100 мВпик-пик | 100 мВпик-пик |
| Стабильность входного провода | ±0,5% | ±1% | ±0,5% | ±0,5% | ±1% | ±0,5% | ±0,5% | ±1% | ±0,5% | ±0,5% | ±1% | ±1% |
| Стабильность нагрузки | ±1% | ±4% | ±1% | ±1% | ±4% | ±4% | ±4% | ±4% | ±1% | ±1% | ±4% | ±1% |
| Series summary power (not per rail) | 60W (series summary; group rating not separately stated) | 60W (series summary; group rating not separately stated) | 60W (series summary; group rating not separately stated) | 60W (series summary; group rating not separately stated) | ||||||||
| Эффективность | 72% | 72% | 72% | 72% | ||||||||
| Регулируемый диапазон напряжения постоянного тока | CH1: ±10%; CH2: ±5%; CH3: ±5% (independent controls not stated) | CH1: ±10%; CH2: ±5%; CH3: ±5% (independent controls not stated) | CH1: ±10%; CH2: ±5%; CH3: ±5% (independent controls not stated) | CH1: ±10%; CH2: ±5%; CH3: ±5% (independent controls not stated) | ||||||||
| Input voltage / frequency | 85 ~ 264VAC; 120 ~ 370VDC; 47 ~ 63Hz | |||||||||||
| AC Inrush Current | Cold start current 30A/115VAC; 60A/230VAC | |||||||||||
| Ток утечки | Not specified in the bound datasheet. | |||||||||||
| Защита от перегрузки | 105% ~ 150% cut off the output, automatic recovery; reference base, channel coverage and waveform not stated. | |||||||||||
| Защита от перенапряжения | CH1: 115 ~ 135%; shut down O/P voltage, re-power on to recover. CH2/CH3 protection not specified. | |||||||||||
| Коэффициент температуры | Not specified in the bound datasheet. | |||||||||||
| Настройка, подъем, удержание времени | 300ms, 50ms, 80ms/230VAC at full load | |||||||||||
| Вибрация | Not specified in the bound datasheet. | |||||||||||
| Выдерживать напряжение | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute. Test waveform not specified; no output-to-output rating stated. | |||||||||||
| Сопротивление изоляции | I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ. Output-to-output isolation and commoning permissions not specified. | |||||||||||
| Working temperature / humidity | -10℃ ~ +50℃; humidity, derating curve and full-temperature full-load conditions not specified. | |||||||||||
| Габаритные размеры | 159 × 98 × 38mm | |||||||||||
| Масса | 0.55kg | |||||||||||
| Стандарты безопасности | Certification not specified in the bound datasheet; verification required. | |||||||||||
| Стандарты ЭМС | Approval not specified in the bound datasheet; verification required. | |||||||||||
| Упаковка | 34 × 32 × 24CM/30PCS/16.5kg | |||||||||||
WEHO T-60W triple output power supply — T-60A / T-60B / T-60C / T-60D
T-60 is an AC/DC triple-output supply for compatible OEM bridge measurement, pressure-signal acquisition and bipolar analog receiver electronics. The document describes a 60W series; each ordered version is a three-channel combination, not three separately approved continuous power ratings. The input row lists 85 ~ 264VAC, 120 ~ 370VDC and 47 ~ 63Hz. Choose the exact voltage combination and qualify the complete joint load, terminal mapping and host enclosure before integration. Send the required combination and measured load profile for model review.
Если у вас есть какие-либо вопросы, пожалуйста, не стесняйтесь обращаться к нам по адресу Электронная почта: [email protected]
- Описание
Why Choose T-60
Choose a documented multi-voltage combination
Examples include T-60B 5V/12V/-12V; T-60C 5V/15V/-15V.
The bipolar alternatives give a host designed for logic and signed analog inputs a clear channel map for its receiver and signal-conditioning boards; actual load and reference compatibility still need qualification.
Build the load review around printed current windows
T-60B lists CH1 0 ~ 5A, CH2 0 ~ 2.5A, CH3 0 ~ 0.5A.
Use the printed windows to review a bridge amplifier or signal receiver as a complete host, with logic and both analog paths identified separately; validate idle and startup demand rather than selecting from the series power name alone.
Match the input specification to the host supply
The input row specifies 85 ~ 264VAC, 120 ~ 370VDC and 47 ~ 63Hz.
Review the receiver host against this model's broad AC row and separate DC row; a switch instruction from a different series is not evidence for this model.
Plan the physical electronics compartment early
The documented envelope is 159 × 98 × 38mm and weight is 0.55kg.
Start the receiver or bridge-instrument compartment around this envelope, then qualify fixing points, service access and ventilation rather than treating outer dimensions as a complete installation drawing.
Features and Benefits
Version-specific triple outputs
The four combinations are T-60A 5V/12V/-5V; T-60B 5V/12V/-12V; T-60C 5V/15V/-15V; T-60D 5V/12V/24. The final T-60D voltage unit is not printed and must be verified.
The complete three-channel table is the selection basis; do not split a single combination into independent output SKUs.
Documented overload and channel-specific overvoltage response
Overload protection is listed as 105% ~ 150% output cut-off with automatic recovery.
CH1 overvoltage protection is 115 ~ 135%, with output recovery after re-powering.
The page does not establish an overload reference base, a hiccup waveform or matching overvoltage thresholds on the other channels.
Timing entries with an explicit test condition
The table lists 300ms setup, 50ms rise and 80ms hold-up at 230VAC and full load.
These values support interruption planning, but do not guarantee host data retention or full-load operation across the complete working-temperature range.
Consistent group efficiency entries
Efficiencies are 72%, 72%, 72%, 72% for T-60A, T-60B, T-60C and T-60D respectively.
The group entries are not per-rail efficiencies, and their load and temperature test conditions are not supplied on the page.
Typical Service Conditions
Assess the complete analog and digital load set
For a host explicitly accepting the specified bipolar analog and logic voltages, assess idle demand and measurement-start transients together.
T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V contact-meter processing-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive analog measurement-board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative analog measurement-board supply input.
Qualify all three channel demands together through idle, startup and transients. Printed current-range lower bounds are not independent minimum-load rules; range endpoints and series-summary power do not establish simultaneous continuous loading.
Variant-specific terminal polarity, return mapping, signal-reference compatibility and protective bonding require separate engineering evidence. Do not assume output commoning, inter-output isolation or permitted strapping; a concealed supply does not waive these prerequisites.
Plan interruption and restart behaviour
Check recovery of the compatible decoding electronics after an input interruption; process-loop excitation and isolation are separately supplied and assessed.
T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V loop-decoder logic-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive analog receiver-board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative analog receiver-board supply input.
Qualify all three channel demands together through idle, startup and transients. Printed current-range lower bounds are not independent minimum-load rules; range endpoints and series-summary power do not establish simultaneous continuous loading.
Variant-specific terminal polarity, return mapping, signal-reference compatibility and protective bonding require separate engineering evidence. Do not assume output commoning, inter-output isolation or permitted strapping; a concealed supply does not waive these prerequisites.
Assess compartment temperature and access
Qualify the mounted receiver compartment with its real joint load, access, ventilation and measured temperature rather than inferring a cooling method from enclosure shape.
T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V waveform-acquisition processing-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive analog receiver-board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative analog receiver-board supply input.
Qualify all three channel demands together through idle, startup and transients. Printed current-range lower bounds are not independent minimum-load rules; range endpoints and series-summary power do not establish simultaneous continuous loading.
Variant-specific terminal polarity, return mapping, signal-reference compatibility and protective bonding require separate engineering evidence. Do not assume output commoning, inter-output isolation or permitted strapping; a concealed supply does not waive these prerequisites.
Confirm returns and signal-reference compatibility
Obtain variant-specific terminal and signal-reference evidence before connecting a compatible bipolar multiplexer front end; source legend labels do not approve return strapping.
T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V sensor-multiplexer controller DC input; CH2 12V (0 ~ 2.5A) for 12V positive analog switching-board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative analog switching-board supply input.
Qualify all three channel demands together through idle, startup and transients. Printed current-range lower bounds are not independent minimum-load rules; range endpoints and series-summary power do not establish simultaneous continuous loading.
Variant-specific terminal polarity, return mapping, signal-reference compatibility and protective bonding require separate engineering evidence. Do not assume output commoning, inter-output isolation or permitted strapping; a concealed supply does not waive these prerequisites.
Application Industries
Weigh-hopper signal processing
Consider only a compatible local weighing-electronics assembly; hopper gates, vibrators, process drives and safety equipment have separate power and qualification.
T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V hopper-weight processing-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive load-cell signal-conditioning board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative load-cell signal-conditioning board supply input.
Jointly qualify controller and bridge-board demand through empty-hopper idle, sampling and restart; the printed ranges are not independent minimum-load or simultaneous continuous-load approval.
Confirm bridge reference, signal returns, terminal mapping and protective bonding for the exact variant before connection; no permission to common outputs or assume inter-output isolation is inferred.
Melt-pressure signal acquisition
Consider compatible local pressure-acquisition electronics only; extrusion heaters, screw drives and machine protection remain separately supplied and qualified.
T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V pressure-acquisition processing-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive pressure-amplifier board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative pressure-amplifier board supply input.
Evaluate pressure-acquisition demand through sensor settling, sample capture and restart as a joint-load problem; endpoint currents are not a separately approved continuous power budget.
Confirm the pressure-amplifier references, returns and variant terminal assignments separately. The generic legend does not approve shared returns or inter-output isolation.
Textile tension-signal conditioning
Consider compatible local tension-measurement electronics, not the web-drive or actuator power; qualify bridge excitation, returns and all channel demands separately.
T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V tension-processing controller DC input; CH2 12V (0 ~ 2.5A) for 12V positive bridge-amplifier board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative bridge-amplifier board supply input.
Assess the complete tension-electronics load during stationary-web idle and signal acquisition; neither range endpoints nor the series description establishes a continuous combined load rating.
Qualify bridge excitation, signal-reference compatibility, return routing and exact terminal assignments for the host; do not infer output commoning or isolation from the signed voltage labels.
Process-analysis detector-signal integration
Consider compatible local detector-signal electronics only; detector bias, heaters, pumps and analytical or hazardous-area approvals are separate requirements.
T-60B is proposed only for CH1 5V (0 ~ 5A) for 5V detector-signal integration-board DC input; CH2 12V (0 ~ 2.5A) for 12V positive detector-amplifier board supply input; CH3 -12V (0 ~ 0.5A) for -12V negative detector-amplifier board supply input.
Review detector-amplifier and processing demand as one host during baseline settling and data capture; the printed ranges are not a metrology-performance or simultaneous-loading approval.
Verify detector-board references, returns, protective bonding and variant-specific wiring before connection. The source does not supply output commoning or inter-output isolation permission.
Technical FAQ
Which voltage combinations belong to T-60?
T-60A 5V/12V/-5V; T-60B 5V/12V/-12V; T-60C 5V/15V/-15V; T-60D 5V/12V/24. The final T-60D voltage unit is not printed and must be verified.
These are complete three-channel model combinations; variant-specific terminal mapping remains a separate engineering prerequisite.
Does the series power description establish an independent rating for every output?
The summary describes 60W for the series.
It does not provide separate continuous per-rail power ratings or simultaneous endpoint-load approval. Voltage-current multiplication must not be used to create those missing ratings.
What current ranges are printed for the exact output combinations?
T-60A: CH1 0 ~ 5A; CH2 0 ~ 2.5A; CH3 0 ~ 0.5A.
T-60B: CH1 0 ~ 5A; CH2 0 ~ 2.5A; CH3 0 ~ 0.5A.
T-60C: CH1 0 ~ 5A; CH2 0 ~ 2A; CH3 0 ~ 0.5A.
T-60D: CH1 0.5 ~ 5A; CH2 0.2 ~ 2.5A; CH3 0.2 ~ 0.5A.
These are literal current ranges, not independent minimum-load or cross-regulation acceptance criteria; qualify all channel demands together.
What input range and selection method are documented?
The input row is 85 ~ 264VAC, 120 ~ 370VDC and 47 ~ 63Hz.
The page does not state an input-selection switch; do not import a switched-band instruction from another model.
Which cold-start current belongs to each input voltage?
Cold-start current is 30A at 115VAC and 60A at 230VAC.
These are voltage-specific inrush entries, not continuous input-current ratings; assess the host input path and protection separately.
How are overload and overvoltage recovery scoped?
Overload protection is 105% ~ 150% output cut-off with automatic recovery.
CH1 overvoltage protection is 115 ~ 135%, with re-powering to recover.
The page does not extend that overvoltage threshold to other channels or define the overload reference base and waveform.
What are the setup, rise and hold-up entries and their condition?
The source lists 300ms setup, 50ms rise and 80ms hold-up at 230VAC and full load.
The explicit full-load timing condition does not establish full-load thermal operation, safe process restart or host data retention.
How do the wave/noise entries vary by model and channel?
T-60A wave/noise: CH1 50mVp-p; CH2 100mVp-p; CH3 100mVp-p.
T-60B wave/noise: CH1 100mVp-p; CH2 120mVp-p; CH3 120mVp-p.
T-60C wave/noise: CH1 100mVp-p; CH2 120mVp-p; CH3 120mVp-p.
T-60D wave/noise: CH1 80mVp-p; CH2 100mVp-p; CH3 100mVp-p.
Probe bandwidth and the complete noise test method are not specified on this page.
Which efficiency, line and load stability entries apply to each version?
T-60A efficiency 72%; line stability ±0.5%/±1%/±0.5% and load stability ±1%/±4%/±1% in CH1/CH2/CH3 order.
T-60B efficiency 72%; line stability ±0.5%/±1%/±0.5% and load stability ±1%/±4%/±4% in CH1/CH2/CH3 order.
T-60C efficiency 72%; line stability ±0.5%/±1%/±0.5% and load stability ±4%/±4%/±1% in CH1/CH2/CH3 order.
T-60D efficiency 72%; line stability ±0.5%/±1%/±1% and load stability ±1%/±4%/±1% in CH1/CH2/CH3 order.
These are group/channel entries, not independent rail efficiency or a complete cross-load regulation method.
How are the printed adjustment ranges and channel labels interpreted?
T-60A printed adjustment cells: CH1: ±10%; CH2: ±5%; CH3: ±5%.
T-60B printed adjustment cells: CH1: ±10%; CH2: ±5%; CH3: ±5%.
T-60C printed adjustment cells: CH1: ±10%; CH2: ±5%; CH3: ±5%.
T-60D printed adjustment cells: CH1: ±10%; CH2: ±5%; CH3: ±5%.
Printed channel adjustment ranges do not establish three independently adjustable controls or simultaneous adjustment behaviour.
What mechanical, thermal and dielectric boundaries are supplied?
Working temperature is -10℃ ~ +50℃; the envelope is 159 × 98 × 38mm and weight is 0.55kg.
Withstand entries are I/P-O/P 1.5kV, I/P-FG 1.5kV and O/P-FG 0.5kV for 1 minute.
The resistance entry names I/P-O/P, I/P-FG and O/P-FG at 500VDC/100MΩ.
Cooling, humidity, derating, full-temperature full-load operation and the withstand AC/DC waveform are not stated. These interface tests do not establish output-to-output isolation or permission to common outputs.
Does the generic terminal legend approve variant-specific wiring?
Pin 5 is printed as DC OUTPUT+V2.
The legend does not establish terminal-to-rail applicability for every signed-output combination, permitted return strapping or inter-output isolation. Obtain the exact variant wiring evidence before connection.
Product information
Our partners can cooperate with us in OEM or ODM.