| Спецификация | S-2400-24 | S-2400-27 | S-2400-36 | S-2400-48 |
| Выходное напряжение постоянного тока, ток | 24V 0 ~ 100A | 27V 0 ~ 89A | 36V 0 ~ 67A | 48V 0 ~ 50A |
| Волна и шум | 120 мВ (пик-пик) | 200 мВпик-пик | 200 мВпик-пик | 240 мВ (пик-пик) |
| Стабильность входного провода | +0.5% | +0.5% | +0.5% | +0.5% |
| Стабильность нагрузки | +0.5% | +0.5% | +0.5% | +0.5% |
| Эффективность | 80% | 85% | 86% | 87% |
| Регулируемый диапазон напряжения постоянного тока | ±10% | ±10% | ±10% | ±10% |
| Диапазон входного напряжения | 200 ~ 264VAC | |||
| Ударный ток | Ток холодного пуска 45 А/230 В переменного тока | |||
| Защита от перегрузки | 105% ~ 135% cut off the output, automatic recovery | |||
| Защита от перенапряжения | Not specified in this datasheet (overvoltage threshold and short-circuit recovery mode are not stated). | |||
| Настройка, подъем, время выдержки | 2000ms, 50ms, 20ms/230VAC at full load | |||
| Выдерживая напряжение | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||
| Сопротивление изоляции | I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ | |||
| Рабочая температура | -10°C ~ +50°C | |||
| Измерение | 291 × 132 × 136mm | |||
| Масса | 5.3kg | |||
| Упаковка | 38 × 37.5 × 21CM/2PCS/11kg | |||
S-2400W series normal single switching power supply
WEHO S-2400 is a 2400W-class enclosed single-output power-supply family with a listed 200~264VAC input. Its four output choices are 24V 0~100A, 27V 0~89A, 36V 0~67A and 48V 0~50A. It is a candidate for substantial DC assembly-test and loading equipment when the exact voltage, wiring and operating duty are validated together; the power-class label and printed current ranges are not an unconditional continuous-duty guarantee.
Если у вас есть какие-либо вопросы, пожалуйста, не стесняйтесь обращаться к нам по адресу Электронная почта: [email protected]
- Описание
Why choose S-2400
Select the rail rather than a headline wattage
The 24V 0~100A and 48V 0~50A columns serve different load interfaces, with separate 27V 0~89A and 36V 0~67A choices. Choose the required model directly; no simultaneous multi-output operation is stated.
Screen the facility input accurately
Both the summary and input row state 200~264VAC. Confirm equipment frequency and actual terminal functions before design, because no low-line band, manual selector, DC-input range or phase configuration is specified.
Plan a substantial enclosed module
The published body size is 291×132×136mm with a listed weight of 5.3kg. Allow space for the complete terminal assembly, fan access and mounting clearances; verify the undimensioned third extent against the delivered unit.
Use a load-driven equipment specification
A rack of DC electronic assemblies or a high-current bus assembly tester can justify this current class after its load budget is established. Merely powering a status board is not a persuasive sizing basis. Establish continuous duty, ambient conditions and wiring losses before making an equipment rating.
S-2400 features
Noise values tied to each output
The table lists 120mVp-p for S-2400-24, 200mVp-p for S-2400-27 and S-2400-36, and 240mVp-p for S-2400-48. Confirm measurement method before applying these figures to sensitive signal equipment.
Published data without sign correction
Both stability rows print +0.5%. The respective efficiency entries are 80%, 85%, 86% and 87% at 24V, 27V, 36V and 48V. The intended stability tolerance and efficiency measurement conditions need confirmation for a contractual specification.
A bounded voltage-trim entry
Visible adjustment is ±10% for each model. Validate the load’s permitted voltage and allowable loading after adjustment; this is not a programmable-output or constant-current-control claim.
Overload cut-off with recovery
The overload row states 105%~135%, cut-off of the output and automatic recovery. Select suitable branch protection and assess restarting loads; no additional protection threshold or permitted fault duration is stated.
S-2400 service conditions
Network-device incoming-power qualification
An industrial network-device production tester must be connected within the 200~264VAC range. Cold-start current is listed as 45A at 230VAC, not a normal running-current value; coordinate the actual upstream circuit and confirm frequency. The proposed DC duty is compatible DC-input network-device assemblies with a documented aggregate load budget; not PoE or communications performance. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.
High-current distribution fixture
A busbar-joint verification machine needs conductors, terminals and fixture contacts matched to the selected output and measured load sequence. The printed current ranges do not independently establish continuous operation, minimum-load behaviour or acceptable joint heating.
Thermal planning for radio-module batches
An industrial radio-module test wall should maintain ventilation around its supply compartment. The listed working range is −10°C~+50°C, but no derating curve or airflow requirement defines full-load performance throughout that range. The proposed DC duty is compatible fixed-voltage DC inputs of radio modules under test, not RF loads or calibrated measurement. Confirm exact product voltage compatibility and aggregate demand; this is selection guidance, not a validated installation.
Restart-coordinated batch testing
A guarded DC branch endurance station must accommodate setup 2000ms, rise 50ms and hold-up 20ms at 230VAC and full load. Confirm the real sequence and automatic-recovery response before reconnecting a faulted fixture.
S-2400 application considerations
High-current electronic-load rack
A deep-frame electronic-load development rack is a potential application with one exact S-2400 output feeding the controlled load. Check transients, conductor voltage drop, load dissipation and continuous thermal duty rather than deriving a new rating from voltage times current.
Large lighting-module batch tests
A pallet-based lighting-assembly inspection line may use a compatible fixed DC rail for multiple protected test branches. Confirm each module voltage and aggregate demand; no built-in dimming, current regulation or complete-machine mains role is implied.
Industrial power-entry assembly tests
A floor-mounted connector-manifold acceptance cell can exercise a defined DC load through a compatible output. Engineer contact resistance, insulation, branch protection and safe access independently from the power-supply family label.
DC backplane production loading
A cabinet-scale backplane loading system may use a selected 24V, 27V, 36V or 48V model for substantial product-side demand. Verify the backplane current distribution and bonding; its motors, heaters and facility mains remain separate circuits.
S-2400 technical FAQs
Which exact output models are listed?
S-2400-24: 24V 0~100A; S-2400-27: 27V 0~89A; S-2400-36: 36V 0~67A; S-2400-48: 48V 0~50A. These are separate model choices, not simultaneous outputs. The lower bound of each printed range is zero; that alone does not establish minimum-load behaviour or a complete continuous-duty specification.
Does the 2400W class label guarantee continuous power in my enclosure?
No. The summary states 2400W for the family, while each output column has its own printed current range. The sheet does not define the continuous-load relationship to ambient temperature, airflow, mounting or adjustment. The printed ranges do not establish a continuous-power rating calculated from voltage times current.
What input range and selection method are documented?
The stated input is 200~264VAC. No input frequency, DC range, low-line switching band or three-phase connection is specified. Obtain the exact unit’s input connection details before installation.
What cold-start current must the upstream design consider?
The listed cold-start current is 45A at 230VAC. It is not a normal running-current figure and no second input condition is supplied. Coordinate the actual circuit and starting sequence rather than extrapolating this value to every input voltage.
What are the setup, rise and hold-up times?
Setup is 2000ms, rise is 50ms and hold-up is 20ms at 230VAC and full load, in that order. These values do not establish the response at another input voltage, a different load or during overload recovery.
What ripple/noise values should be used for selection?
S-2400-24: 120mVp-p; S-2400-27: 200mVp-p; S-2400-36: 200mVp-p; S-2400-48: 240mVp-p. Measurement bandwidth, probing and load conditions are not given. Validate compatibility with sensitive loads using the agreed test method.
How are stability and efficiency specified?
The line-stability and load-stability rows each print +0.5% for all four models. S-2400-24: 80%; S-2400-27: 85%; S-2400-36: 86%; S-2400-48: 87%. The one-sided +0.5% notation is shown; a symmetric tolerance is not stated. Efficiency measurement conditions are not stated; these entries do not prove system-level heat rejection.
How much voltage adjustment is shown?
The visible table shows ±10% DC-voltage adjustment for each selected model. Check device voltage tolerance and permitted current at the chosen setting. Adjustment does not establish a programmable control interface, constant-power operation or interchangeability with another model.
What overload behaviour is stated?
The threshold is 105%~135%, with output cut-off and automatic recovery. No permissible fault duration, recovery waveform or additional short-circuit/overvoltage action is stated. Engineer external protection and safe restart independently.
What do the temperature and insulation entries establish?
Working temperature is listed as −10°C~+50°C without a derating curve or airflow requirement. Withstand values are 1.5kV input-to-output, 1.5kV input-to-frame and 0.5kV output-to-frame for one minute; AC/DC waveform is not specified. Isolation resistance is listed as 100MΩ at 500VDC for those pairs. These tests do not authorize a common-ground or output-strapping arrangement.
What mechanical and shipping information is available?
The table lists 291×132×136mm, 5.3kg and packing 38×37.5×21CM/2PCS/11kg. The drawing shows a 291mm chassis span, 132mm depicted face/span and 30mm post projection, but does not separately dimension the table’s 136mm extent. Verify mounting reference points, actual orientation, terminal clearances and service space before approving fit.
Can I wire the equipment from the outline drawing alone?
The input drawing has five screw symbols, with only the middle three numbered 1, 2 and 3; it provides no L/N/FG function legend. The output end shows POS(+)/+V, NEG(−)/−V and LED with additional contact symbols. Confirm the actual input functions, output-contact relationship, bonding, conductor sizes, torque and branch protection; do not infer strapping from the drawing.