LRS-200 Series 200W Single Output Enclosed Switching Power Supply (LRS-200-12 / LRS-200-24 / LRS-200-48)

The LRS-200 is a 200W-class single-output enclosed power supply with a 30mm-high body. Select 90–132VAC or 180–264VAC using the input-range switch; the DC input range is 240–370VDC and the AC frequency range is 47–63Hz. Output versions are 12V, 15V, 24V and 48V. Match the exact model suffix and listed current range to the load.
LRS-200 series serves as a high-price-to-performance power supply solution for various industrial applications.

Kung mayroon kang anumang mga katanungan, mangyaring huwag mag-atubiling makipag-ugnay sa amin sa Email: [email protected]

Pagtutukoy LRS-200-12 LRS-200-15 LRS-200-24 LRS-200-48
DC output boltahe, kasalukuyang 12V 0~17A 15V0~14A 24V0~8.8A 48V 0~4.4A
Kaway at ingay 150mVp-P 150mVp-P 150mVp-P 200mVp-P
Katatagan ng inlet wire ±0.5% ±0.5% ±0.5% ±0.5%
Katatagan ng pag-load ±0.5% ±0.5% ±0.5% ±0.5%
Kahusayan 85.5% 86% 88% 89%
Adjustable range para sa DC boltahe ±10% ±10% ±10% ±10%
Saklaw ng boltahe ng input 90–132VAC / 180–264VAC by switch; 240–370VDC; 47–63Hz
Kasalukuyang epekto Cold start current 60A/230VAC
Proteksyon ng labis na karga 110%~150%cut off the output,automatic recovery
Iba pang proteksyon Overcurrent protection /Short-circuit protection
Setup, rise, hold uptime 1500ms,50ms/230VAC 1500ms,50ms/115VAC
Makatiis ng boltahe I/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1min
paglaban sa paghihiwalay I/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH
Temperatura ng pagtatrabaho -20℃~+70℃
Dimensyon 215×115×30mm
Timbang 0.66kg
Pag-iimpake 37.5×25×26CM/20PCS/13kg

Mechanical dimensions

LRS-200 — dimensions in millimetres
Body length215 mm
Body width115 mm
Body height30 mm
Width including mounting ears135 mm

The body dimensions and mounting-hole dimensions are different references. The vector drawing below retains the dimensions printed in the WEHO original.

On a small screen, swipe the drawing horizontally to inspect every dimension. No separate drawing image or script download is required.

Exact mechanical drawing from the WEHO original. Units: mm. Use the printed body, mounting and hole dimensions separately.

Load derating

Apply these model-specific curves only within the stated WEHO operating range of -20 to +70 °C and the input range in the specification table. A reference axis extending below that range does not extend the product rating. Follow the input-voltage and mounting-orientation labels shown on each curve.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus ambient temperature. Observe the separate input-voltage curves where shown.
Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus AC input voltage at the frequency shown. Use the correct input selector setting where applicable.
View the functional block diagram Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.

Overview

The LRS-200 is an enclosed single-output power supply for proposed integration into industrial auxiliary DC distribution. The LRS-200 specification lists LRS-200-12, LRS-200-15, LRS-200-24, LRS-200-48. It suits consideration for sensor, relay and actuator-interface groups whose combined demand is assessed as part of the machine design. State the AC range, selected output and simultaneous load profile for a model-specific review.

Why Choose LRS-200?

Build a selected-input machine platform

The LRS-200 AC input is 90–132VAC or 180–264VAC, selected by a switch; the table also lists 240–370VDC and 47–63Hz. Use a defined input-range selection step when configuring the host equipment for its destination supply.

Compare the actual output columns

The documented output choices are 12V 0~17A; 15V 0~14A; 24V 0~8.8A; 48V 0~4.4A. Match the equipment voltage first so the selected version serves a defined DC rail rather than a collection of incompatible loads.

Use a shallow equipment compartment

The LRS-200 dimensions are 215×115×30mm. The stated height helps plan a shallow host compartment while wiring, ventilation and service space are assessed separately.

Coordinate start-up with the whole machine

The inrush entry is “Cold start current 60A/230VAC”. Coordinate the input switching and the simultaneous auxiliary loads as part of the machine start-up sequence.

Features, Benefits & Advantages

Feature Benefit in equipment design
Output choices for DC distribution The output table lists 12V 0~17A; 15V 0~14A; 24V 0~8.8A; 48V 0~4.4A. Use the selected output column as the starting point for the connected-device budget.
Regulation and ripple stated by column Line regulation and load regulation are each ±0.5%. The wave-and-noise figures are 150mVp-p, 150mVp-p, 150mVp-p, 200mVp-p for the output columns in the listed order. Compare these figures with the electronics tolerance and any required downstream filtering.
Voltage adjustment for load matching The DC-voltage adjustment range is ±10%. Set the output only within the connected equipment limits, and check voltage at the load under representative demand.
Specified fault and recovery behavior The source lists overload, overcurrent and short-circuit protection. The overload response is output cut-off and automatic recovery at the stated 110%–150% range. This response helps define host fault handling; it is not extra continuous load capacity.

Typical Service Conditions

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


Select 90–132VAC or 180–264VAC manually before energizing, then verify the chosen DC output and polarity.

Input and load matching for LRS-200

The LRS-200 AC input is 90–132VAC or 180–264VAC, selected by a switch; the table also lists 240–370VDC and 47–63Hz. Check the actual incoming supply and the complete input-protection arrangement before commissioning. Match the selected DC version to every connected input, then include simultaneous demand and startup transients before energising the equipment. The planning image is a representative LRS-series example, not an exact-model wiring diagram.

LRS-350 manual-selector planning example; use LRS-200 input bands, selection instructions and output options, not the example labels.


Keep fan and ventilation openings unobstructed inside a cabinet selected for the actual environment. Arrows show conceptual airspace, not a measured airflow path.

LRS-200 enclosure and service-space planning

The printed dimensions are 215×115×30mm and the weight is 0.66kg. Reserve additional space for wiring, access and the host ventilation arrangement; the body dimensions are not installation clearances. Reserve additional space for terminal access, conductor routing and the host equipment's airflow; the case outline is not a clearance allowance.

LRS-series cabinet-space concept; the exact case, cooling method and mounting are defined by this model's own technical data.


The −20°C to +70°C working range does not establish full output at every temperature. Use the selected version’s load and thermal limits.

Temperature and duty-cycle assessment for LRS-200

The specified working-temperature range is -20°C to +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. Measure the temperature at the installed supply and review the longest expected duty cycle. Keep vents unobstructed; do not substitute room temperature for the operating temperature inside the equipment.

LRS-350 temperature-planning example, not a measured derating curve or a replacement for LRS-200 operating limits.


Functional power-planning illustration only. Have qualified personnel select protection, follow terminal markings and verify safe isolation before work.

LRS-200 fault recovery and protected installation

Overload protection is 110%–150%, with output cut-off and automatic recovery; overcurrent and short-circuit protection are also listed. Coordinate the host fault response and branch protection with real load behavior; automatic recovery is not a redundancy or backup function. Have a qualified installer check terminal identification, protective earthing and branch protection for the actual assembly. Coordinate restart behaviour with the equipment controls rather than treating supply recovery as a safety function.

Functional power-planning illustration only; follow the exact model's terminal identification and qualified installation instructions.



Application Industries

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


AI illustration of an illuminated retail lightbox and storefront at blue hour.

Retail sign-control and LED-module branches

For a retail display with several lighting zones, consider LRS-200 only for the documented compatible DC groups included in the branch schedule. Check their combined startup and longest duty cycle, and protect the distribution. Bare LED strings still need suitable current control.

Proposed output: LRS-200-24, with the printed output entry 24V 0~8.8A.

AI application concept — retail signage, not an installation record for this product.


AI illustration of complete self-service parcel lockers and a central pickup screen in a bright indoor lobby.

Parcel-terminal interface electronics

A larger locker installation can budget controller electronics and scheduled door releases as distinct loads. Evaluate the LRS-200 version against the worst permitted simultaneous combination and each peripheral input. The picture does not qualify all locks, display power or emergency operation together.

Proposed output: LRS-200-24, with the printed output entry 24V 0~8.8A.

AI application concept — parcel-terminal electronics, not an installation record for this product.


AI illustration of a complete guarded automatic carton-packing machine on a production floor.

Carton-packaging auxiliary electronics

On a carton-packing machine, consider LRS-200 for a matched auxiliary group containing sensors, relay interfaces and controller electronics. Review simultaneous pickup and behaviour after recovery. Feed the main drives and heaters separately, with the equipment safety design independent of the supply recovery.

Proposed output: LRS-200-15, with the printed output entry 15V 0~14A.

AI application concept — carton-packaging auxiliary electronics, not a complete-machine power claim.


AI illustration of an electronics inspection workbench with a supported PCB fixture and optical inspection equipment.

Electronics-fixture auxiliary interfaces

For several connected inspection fixtures, assess LRS-200 against the measured auxiliary-control demand and any converter inrush. Distribute power through appropriately protected branches. Measurement excitation, DUT power and optical accuracy remain separately specified functions.

Proposed output: LRS-200-48, with the printed output entry 48V 0~4.4A.

AI application concept — electronics-fixture interfaces; no measurement-performance or installed-model claim.



Frequently Asked Questions

What DC output options does the LRS-200 specification list?

The listed versions are LRS-200-12: 12V 0~17A; LRS-200-15: 15V 0~14A; LRS-200-24: 24V 0~8.8A; LRS-200-48: 48V 0~4.4A. Each is a separate output choice, not a simultaneous multi-output rail set.

What input range does the LRS-200 require?

The LRS-200 AC input is 90–132VAC or 180–264VAC, selected by a switch; the table also lists 240–370VDC and 47–63Hz. Check the actual incoming supply and the complete input-protection arrangement before commissioning. Set and verify the AC-range switch with input power isolated.

How does the LRS-200 series power statement relate to its output-current table?

The manufacturer summary states “Single output: power 200W”. Its separate output table lists 12V 0~17A; 15V 0~14A; 24V 0~8.8A; 48V 0~4.4A. The sheet does not provide a separate per-version continuous-power row; the series statement and current endpoints remain separate source statements rather than a recalculated continuous rating. Confirm the selected version against the intended continuous and transient load profile without treating the current endpoint as an independently proven continuous-power rating.

What output adjustment does the LRS-200 provide?

The specified DC-voltage adjustment is ±10%. Match the final setting to the connected device limits; adjustment does not turn a selected version into every other output version.

What regulation and wave-and-noise figures does the LRS-200 list?

Line and load regulation are each ±0.5%. Wave and noise are LRS-200-12: 150mVp-p; LRS-200-15: 150mVp-p; LRS-200-24: 150mVp-p; LRS-200-48: 200mVp-p. Compare the load tolerance and measurement arrangement before deciding whether local filtering is needed.

What efficiency figures does the LRS-200 specify?

The efficiency entries are LRS-200-12: 85.5%; LRS-200-15: 86%; LRS-200-24: 88%; LRS-200-48: 89%. These column-specific figures support loss comparison, not an all-load efficiency guarantee.

What protection response does the LRS-200 document?

Overload protection is 110%–150%, with output cut-off and automatic recovery; overcurrent and short-circuit protection are also listed. Coordinate the host fault response and branch protection with real load behavior; automatic recovery is not a redundancy or backup function.

What input-starting current does the LRS-200 specify?

The inrush entry is “Cold start current 60A/230VAC”. Include input-starting behavior when selecting upstream switching and protection; this is not the DC output-current rating.

What timing values does the LRS-200 actually provide?

Under “Setup, rise, hold up time”, the printed entry is “1500ms,50ms/230VAC 1500ms,50ms/115VAC”. Only the printed time pairs are available; no separate hold-up value or at-full-load condition is stated. An interruption-sensitive controller therefore needs a system-level restart or ride-through assessment, not an assumed hold-up duration.

What temperature and cooling boundaries apply to the LRS-200?

The specified working-temperature range is -20°C to +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. The operating interval alone is not a promise of full output at every temperature. Assess mounting, airflow, actual load and temperature in the finished equipment; the reference curve does not expand the WEHO model's stated operating or output ratings.

What size and weight does the LRS-200 list?

The printed dimensions are 215×115×30mm and the weight is 0.66kg. Reserve additional space for wiring, access and the host ventilation arrangement; the body dimensions are not installation clearances.

What withstand and isolation entries does the LRS-200 provide?

The withstand entry is “I/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute”. The isolation-resistance entry is “I/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH”. These are the source test entries, not proof of a product certification or the compliance of the completed equipment.